<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>旋进旋涡流量计技术文章 - 金湖凯铭仪表</title>
	<atom:link href="https://www.zhanfengdesign.com/category/news/xjxwllj-article/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.zhanfengdesign.com/category/news/xjxwllj-article/</link>
	<description>流量&#124;液位&#124;温度&#124;压力</description>
	<lastBuildDate>Wed, 22 Jul 2026 07:27:44 +0000</lastBuildDate>
	<language>zh-Hans</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.2</generator>

<image>
	<url>https://www.zhanfengdesign.com/wp-content/uploads/2026/05/微信图片_20250805143107_120_3-100x100.png</url>
	<title>旋进旋涡流量计技术文章 - 金湖凯铭仪表</title>
	<link>https://www.zhanfengdesign.com/category/news/xjxwllj-article/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>旋进旋涡与涡街流量计管道振动抗干扰能力横向对比</title>
		<link>https://www.zhanfengdesign.com/9515/</link>
					<comments>https://www.zhanfengdesign.com/9515/#respond</comments>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Wed, 22 Jul 2026 07:27:16 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false">https://www.zhanfengdesign.com/?p=9515</guid>

					<description><![CDATA[<p>锅炉、空压机厂区管道长期存在持续性机械振 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/9515/">旋进旋涡与涡街流量计管道振动抗干扰能力横向对比</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">锅炉、空压机厂区管道长期存在持续性机械振动，两种气体计量仪表受振动影响程度差距显著，<a href="https://www.zhanfengdesign.com/xjxwllj/">旋进旋涡流量计</a>常用于中小管径工业气体监测。</p>



<p class="wp-block-paragraph">一、内部结构振动敏感根源对比<br>涡街流量计核心检测部件为独立旋涡发生体，探头外露于流通管道，管道传递的机械振动会直接带动探头同步震动，极易产生额外干扰频率，与流体旋涡信号叠加混淆。<br>旋进旋涡流量计导流、检测元件整体集成于封闭腔体内，无外露细长感应探头，整体结构刚性更强，外部振动不易直接干扰内部检测单元。</p>



<p class="wp-block-paragraph">二、低频管道振动工况表现<br>风机、水泵带来的低频共振是现场最常见干扰。涡街受低频振动影响极大，即便正常气体流速，仪表也会出现无规律流量跳变，零点频繁偏移，需要额外加装减震支架。<br>旋进旋涡流量计对低频振动过滤能力更强，同等振动强度下，输出流量曲线平稳，不会产生虚假流量信号，中小型厂区振动管线可简化减震配套。</p>



<p class="wp-block-paragraph">三、高频剧烈振动工况耐受性能<br>锅炉蒸汽管线、大功率空压机管路高频震动幅度大。涡街探头长期高频震动易出现焊缝松动、元件疲劳，长期运行会永久损伤传感部件；<br>旋进旋涡无高速转动零件、无细长探测杆，高频振动仅轻微影响信号精度，不会造成内部构件松动损坏，设备使用寿命受振动影响更小。</p>



<p class="wp-block-paragraph">四、现场安装适配差异<br>涡街流量计对管路减震、前后直管段、固定支架要求严格，振动环境下必须增设缓冲减震结构，施工成本更高；<br>旋进旋涡流量计对流场、振动包容度更高，现场安装空间狭小、无法布置多重减震支架的工况也可稳定投用。</p>



<p class="wp-block-paragraph">五、工况选型总结<br>管道振动剧烈、中小型管径、昼夜流量波动大的厂区供气管道，优先选用旋进旋涡流量计；管路振动微弱、大流量稳定输送管线可选用涡街流量计。根据现场振动强度匹配仪表类型，能够减少振动带来的计量失真，降低设备故障检修频率。</p>
<p><a href="https://www.zhanfengdesign.com/9515/">旋进旋涡与涡街流量计管道振动抗干扰能力横向对比</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.zhanfengdesign.com/9515/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>电池供电旋进旋涡流量计野外无电管网选型要点</title>
		<link>https://www.zhanfengdesign.com/9377/</link>
					<comments>https://www.zhanfengdesign.com/9377/#respond</comments>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Sun, 12 Jul 2026 01:59:53 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false">https://www.zhanfengdesign.com/?p=9377</guid>

					<description><![CDATA[<p>野外燃气输配管网、偏远厂区供气支线、郊外 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/9377/">电池供电旋进旋涡流量计野外无电管网选型要点</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">野外燃气输配管网、偏远厂区供气支线、郊外工艺气管网普遍存在无外接220V市电、布线困难、运维巡检不便等问题，常规外接供电计量设备无法正常使用。低功耗自持供电计量设备是野外管网计量的核心首选，<a href="https://www.zhanfengdesign.com/xjxwllj/">电池供电旋进旋涡流量计</a>凭借无需外接电源、防护等级高、免运维、适配恶劣户外环境的优势，广泛应用于各类无电野外气体计量场景。</p>



<p class="wp-block-paragraph">一、野外无电管网核心工况特点<br>野外管网与厂区室内管网工况差异显著，对仪表选型有着特殊要求。首先是供电受限，现场无市电铺设条件，无法支持持续外接供电；其次是环境恶劣，常年经受日晒、暴雨、霜冻、风沙侵蚀，昼夜温差极大；再者管网多为间歇供气、负荷波动大，且管道振动、气流紊乱现象频发；最后站点分布零散、距离较远，人工定期运维难度大、成本高，要求设备长期稳定运行、低故障率、超长续航。</p>



<p class="wp-block-paragraph">二、低功耗电池续航选型要点<br>无电野外场景选型核心为微功耗续航能力，需选用专用低功耗主板芯片，整机静态功耗极低，杜绝无效耗电。标配大容量内置锂电池组，无需外接电源、无需布线施工，满电状态下可连续稳定工作5年以上，适配野外长期无人值守工况。设备支持智能休眠、按需采样机制，低流量静置时段自动降低采样频率，进一步节省电量，避免频繁没电停机、数据中断问题。同时支持断电数据自动保存，防止极端天气、设备休眠导致的计量数据丢失，保障气量统计连续可溯源。</p>



<p class="wp-block-paragraph">三、户外防护与耐候选型标准<br>针对野外露天、管井安装环境，设备防护等级必须达到IP65及以上，具备防尘、防水、防暴雨冲刷、防风沙侵蚀能力，可适配夏季高温暴晒、冬季低温霜冻的极端温差环境。整机外壳采用高强度铝合金或不锈钢材质，表面防腐喷塑处理，抗紫外线、耐老化，长期户外使用不褪色、不开裂、不生锈。内部电路采用灌胶密封工艺，杜绝凝露、潮气渗入机芯，避免电路板腐蚀短路，保障野外全天候稳定运行。</p>



<p class="wp-block-paragraph">四、防爆与安全合规选型要求<br>野外天然气管网、工艺气体管网属于易燃易爆工况，设备必须满足防爆安全规范，统一选配Ex d IIB T6隔爆防爆等级，全密封防爆结构，无电火花外泄风险，完全适配野外燃气输送高危环境。电池仓、接线仓独立密封隔离，杜绝电池发热、电路故障引发的安全隐患，符合燃气安监、消防验收标准，适配野外无人值守管网安全运行要求。</p>



<p class="wp-block-paragraph">五、功能与工况适配选型要点<br>野外管网温压波动大、气体密度随环境气候变化明显，选型必须搭载一体化智能温压补偿功能，可实时采集现场温度、压力参数，自动换算标准标况流量，消除环境工况变化带来的计量偏差，解决野外无人工校准、数据不准的痛点。设备无机械转动部件，依靠旋涡感应原理计量，无磨损、无卡顿、无堵塞风险，适配野外含微量杂质、水汽的普通气体工况，故障率远低于传统机械式仪表。<br>同时优先选用宽量程比机型，量程比不低于10:1，完美适配野外管网低负荷静置、高负荷输气的流量波动工况，杜绝小流量计量盲区，保障全时段计量精准。</p>



<p class="wp-block-paragraph">六、信号传输与远程管控选型<br>针对野外巡检不便的痛点，设备可选配RS485无线传输模块，无需布线即可实现流量数据远程上传，支持后台实时查看瞬时流量、累积气量、设备状态，减少人工现场巡检频次。机身自带高清液晶就地显示，无惧强光、弱光环境，现场读数清晰直观，满足偶尔现场核查抄表需求。无外接线缆设计，彻底解决野外布线繁琐、线路老化、线缆破损故障等问题。</p>



<p class="wp-block-paragraph">七、野外专属安装与运维选型规范<br>设备对直管段要求宽松，上游预留3DN、下游预留1DN平直管道即可，适配野外老旧管网、改造受限工况，降低施工改造成本。安装位置避开管道强振动区域、低洼积水区域，做好支架固定防护，防止风沙、水流冲击造成设备偏移。得益于低功耗、无易损件结构，设备基本实现免维护运行，仅需数年一次更换电池、定期外观检查即可，极大降低野外管网运维成本。</p>



<p class="wp-block-paragraph">八、选型总结<br>野外无电管网流量计选型，核心围绕超长续航、高耐候防护、防爆合规、温压补偿精准计量四大核心维度。依托微功耗自持供电、无布线、免运维的核心优势，完美适配郊外燃气支管、偏远工艺气管网、无电场站等特殊场景，长期稳定完成气体能耗统计、管网流量监测工作，为野外无人值守管网智能化、精细化计量管控提供可靠保障。</p>
<p><a href="https://www.zhanfengdesign.com/9377/">电池供电旋进旋涡流量计野外无电管网选型要点</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.zhanfengdesign.com/9377/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>旋进旋涡流量计选型参考要素，气体介质与现场工况匹配梳理</title>
		<link>https://www.zhanfengdesign.com/9128/</link>
					<comments>https://www.zhanfengdesign.com/9128/#respond</comments>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Wed, 24 Jun 2026 08:43:24 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false">https://www.zhanfengdesign.com/?p=9128</guid>

					<description><![CDATA[<p>一、气体介质相关选型要素 二、现场工艺工 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/9128/">旋进旋涡流量计选型参考要素，气体介质与现场工况匹配梳理</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">一、气体介质相关选型要素</p>



<ol class="wp-block-list">
<li>介质洁净程度<br>介质内粉尘、水汽、油雾会附着旋涡发生体与感应元件，干扰信号采集，影响计量状态。<br>1）干燥洁净气体：天然气、氮气、干燥压缩空气等，可选用常规标准结构；<br>2）含粉尘、轻质油雾的燃气或工艺气体，仪表上游管路配套过滤除尘装置；<br>3）长期携带大量液态凝露、固体杂质的混合气体，不建议选用<a href="https://www.zhanfengdesign.com/xjxwllj/">旋进旋涡流量计</a>。</li>



<li>介质腐蚀属性<br>结合气体腐蚀组分，确定测量管、感应探头、密封件接触材质：<br>1）天然气、氮气、空气等中性气体，接触部件选用 304 不锈钢；<br>2）含微量硫化物、弱腐蚀工艺气体，可选用 316 不锈钢接触组件；<br>3）高腐蚀性酸性工艺气体，该类仪表难以长期稳定运行，可更换其他计量设备。</li>



<li>气体组分与凝露风险<br>气体组分、温压条件会改变气体密度，直接影响补偿计算结果。<br>1）单一洁净气体，可按照介质参数匹配对应标定区间仪表；<br>2）多组分混合燃气，需明确各组分占比，用于温压补偿模块参数设置；<br>3）易液化、饱和蒸气压偏高气体，核算工况温压下凝露可能性，配套气液分离辅件。</li>
</ol>



<p class="wp-block-paragraph">二、现场工艺工况选型要素</p>



<ol class="wp-block-list">
<li>流量量程匹配<br>1）统计管路日常最小、最大瞬时工况流量，常规工作流量建议处于仪表量程中段；<br>2）核对仪表始动流量，管路长期最低流量不可低于该数值，否则无法产生有效检测信号；<br>3）存在短时峰值流量的管线，选型预留流量区间余量，减少仪表长期满量程运行。</li>



<li>公称通径与连接方式<br>结合管道管径、检修拆装需求选择连接结构：<br>1）DN15~DN50 中小口径支线、民用燃气管道：螺纹连接为主；<br>2）DN80 及以上工业燃气主管、工艺气体管道：法兰连接；<br>3）需要频繁拆卸维护的计量点位，可选用快装法兰结构。</li>



<li>工作温度、压力<br>1）介质温度：区分常温、中温工况，核对内部感应元件、密封圈耐温参数，超出适配区间会加速密封老化；<br>2）管路承压：按照系统长期工作压力、瞬时冲击压力，匹配对应压力等级本体与法兰组件；<br>3）户外低温管网，同步规划仪表防冻配套措施。</li>



<li>温压补偿配置区分<br>1）仅用于车间内部能耗粗略统计，工况温压波动幅度小，可选用无补偿基础型号；<br>2）管网贸易结算、精准能耗统计、工况温压变化幅度较大场景，选用集成温压补偿一体式结构；<br>3）管道温度偏高，表头不宜贴近管道的点位，可选择分体采集温压组件。</li>



<li>现场环境条件<br>1）常规室内通风厂房：标准一体式旋进旋涡流量计即可满足使用；<br>2）燃气、化工易燃易爆生产区域，匹配对应防爆等级变送模块；<br>3）管道架设高度较高，人员难以近距离查看数据，选用分体式结构，表头布置在便于操作区域；<br>4）露天多雨潮湿点位，选用高防护等级表头，可搭配防雨保护箱体；<br>5）周边布置变频器、大功率电机等强电磁设备，可选用带屏蔽信号输出组件的型号。</li>



<li>供电与信号输出<br>根据后端数据采集设备需求选型：<br>1）仅现场就地查看流量数值，搭配液晶就地显示表头；<br>2）对接二次数显仪表、PLC 控制系统，选用脉冲、4-20mA 电流输出；<br>3）需要中控远程集中采集数据，选择支持 RS485 Modbus 通讯输出型号；<br>4）户外无稳定 24V 供电的独立计量点位，选用内置电池供电表头；<br>5）厂区、门站具备稳定供电线路，采用 24V 直流外供电结构。</li>
</ol>



<p class="wp-block-paragraph">三、配套结构与辅件匹配梳理<br>1.流场优化配件：管路弯头、阀门密集，直管段长度不足时，配套管道整流器改善气流状态；<br>2.前置过滤部件：含粉尘、油雾气体，在上游安装过滤器，减少杂质进入测量腔体；<br>3.气液分离装置：介质易产生凝露的管线，加装分离器，避免液体附着感应探头；<br>4.标定结构：用于贸易计量的仪表，选择预留在线、离线标定接口的款式，方便周期核查。</p>



<p class="wp-block-paragraph">四、工况适配汇总<br>适配场景<br>干燥洁净单一或混合低压气体、居民小区燃气管道、小型锅炉房供气、氮气 / 压缩空气工艺管线、中小型工业燃气支线，用于能耗监测、管网计量。<br>不适配场景<br>高粉尘、大量液态凝露的混合气体、强腐蚀工艺气体、气固混合介质、管路流量长期低于仪表始动流量的微小低压管线。</p>
<p><a href="https://www.zhanfengdesign.com/9128/">旋进旋涡流量计选型参考要素，气体介质与现场工况匹配梳理</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.zhanfengdesign.com/9128/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>旋进旋涡流量计没有输出信号原因分析</title>
		<link>https://www.zhanfengdesign.com/2967/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Wed, 17 Jan 2024 09:05:00 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>旋进旋涡流量计在使用的时候，不可避免的会 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/2967/">旋进旋涡流量计没有输出信号原因分析</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p>旋进旋涡流量计在使用的时候，不可避免的会出现一些小小的问题，所以我们在使用的时候需要及时检查以及定期维护，及时发现故障并解决。小编在此讲述一些关于流量计在使用中会出现的问题、原因以及排查方法，希望能够帮助到大家。</p>
<p>&nbsp;</p>
<p>1、<a href="https://www.zhanfengdesign.com/xjxwllj/">旋进旋涡流量计</a>若出现瞬时流量示值显示不稳定的情况，可能是由于壳体内有杂物；放大器灵敏度过低或过高、有漏计脉冲现象；流量低于限值；接地不良；后部密封圈伸入管道形成扰动；介质流量不稳等。</p>
<p>排查方法：换前置放大器；检查接地线路，使之正常；待流量稳定后再测；排除脏物。</p>
<p>&nbsp;</p>
<p>2、旋进旋涡流量计接通电源后无输出信号，若出现这种情况，一般是由于电源与输出线连接不正确；积算仪显数正常，驱动放大器电路损坏；管道无介质流动或流量低于始动流量；积算仪不计数，瞬时值为，前置放大器损坏。</p>
<p>排查方法：正确接线；换驱动放大器中损坏的元器件；换用较小通径的流量计或者提高介质流量，使其符合流量范围的要求；换前置放大器。</p>
<p>&nbsp;</p>
<p>3、旋进旋涡流量计若出现无流量时但流量计有信号输出的情况，可能是由于放大器产生自激或灵敏度过高；滤波不良，供电电源不稳及其它电气干扰；流量计强电及接地不良和其它地线接线受干扰。</p>
<p>排查方法：换前置放大器；换、修理供电电源，排除干扰；正确接好地线，排除干扰。</p>
<p><a href="https://www.zhanfengdesign.com/2967/">旋进旋涡流量计没有输出信号原因分析</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>旋进旋涡流量计测量不准确的原因</title>
		<link>https://www.zhanfengdesign.com/2966/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Wed, 17 Jan 2024 09:03:33 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>旋进旋涡流量计是近几十年来开发并投入市场 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/2966/">旋进旋涡流量计测量不准确的原因</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p>旋进旋涡流量计是近几十年来开发并投入市场的一种流体振荡式流量计,可适用于天然气、空气、氧气、氩气等多种气体的流量测量。具有结构紧凑、读数直观清晰、可靠性高、不受外界电源干扰、抗雷击、成本低等明显优点，广泛的应用于石油、化工、电力、冶金、煤炭等行业各种气体的计量。</p>
<p>&nbsp;</p>
<p>在实际使用过程中，常常会因为各种的原因导致<a href="https://www.zhanfengdesign.com/xjxwllj/">旋进旋涡流量计</a>测量精度不准确，这些原因大致有以下几个方面：</p>
<p>1.旋进旋涡流量计机械振动</p>
<p>管道的强烈机械振动会对流量计产生影响，VN系列流量计的抗机械振动能力强，但在有强烈机械震动的场合，VN系列流量计的度可能会降低。</p>
<p>&nbsp;</p>
<p>2.旋进旋涡流量计电磁干扰</p>
<p>无论是标定设定参数，还是厂家设定参数，均存于旋进旋涡流量计积算仪中的电可擦可编程只读存储器(EEPROM)中，在断电的情况下也可长期保存，当遇到强烈的电磁干扰冲击或其他较强干扰时，这些参数也存在部分变化的可能性。</p>
<p>&nbsp;</p>
<p>3.气体杂质</p>
<p>气体分离不彻底，气质含有较大颗粒或有较长纤维杂物时会堵塞流量计，影响流量计传感器对涡流旋转频率的测量，使流量计的下降;另外，分离不彻底的天然气气质中含有液体，会腐蚀流量计的各个连接部位和传感器，连接部位使用的密封垫片腐蚀后会造成流量计的局部渗漏，影响了流量计的计量。</p>
<p>&nbsp;</p>
<p>旋进旋涡流量计内置式压力、温度、流量传感器，安全性能高,结构紧凑，外形美观。就地显示温度、压力、瞬时流量和累积流量。采用新型信号处理放大器和独特的滤波技术，有效地剔除了压力波动和管道振动所产生的干扰信号，大大提高了流量计的抗干扰能力，使小流量具有出色的稳定性。特有时间显示及实时数据存储之功能，无论什么情况，都能保证内部数据不会丢失,可靠性保存。整机功耗极低,能凭内电池长期供电运行,是理想的无需外电源就地显示仪表。防盗功能可靠，具有密码保护,防止参数改动。</p>
<p><a href="https://www.zhanfengdesign.com/2966/">旋进旋涡流量计测量不准确的原因</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>如何确保旋进旋涡流量计的使用精度</title>
		<link>https://www.zhanfengdesign.com/2899/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Sat, 07 Oct 2023 09:32:56 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>旋进旋涡流量计的作为一种测量气体介质的仪 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/2899/">如何确保旋进旋涡流量计的使用精度</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p>旋进旋涡流量计的作为一种测量气体介质的仪表装置，因其具有无机械可动部件，耐腐蚀，稳定可靠，寿命长，长期运行无须特殊维护；实现了机电一体化，日常的计量过程不需人工值守；工艺安装条件不苛刻，仪表上、下游直管段可较孔板和涡街流量计大大缩短；系统的测量准确度能够满足目前的贸易计量要求。</p>
<p>&nbsp;</p>
<p><a href="https://www.zhanfengdesign.com/xjxwllj/">旋进旋涡流量计</a>工作原理及其流程</p>
<p>旋进旋涡流量计属于速度式测量仪表，当沿着轴向流动的流体进入流量传感器入口时,旋涡发生体叶片强迫流体进行旋转运动,于是在旋涡发生体中心产生旋涡流。旋涡流在文丘里管中旋进,到达收缩段突然节流使旋涡流加速,当旋涡流进入扩散段后,因回流的作用强迫进行螺旋状进动。此时旋涡流的旋转频率和流体的流速成正比。压电式传感器检测到微弱电信号通过前置放大器等处理就可以得到我们需要的流量信号。</p>
<p>&nbsp;</p>
<p>造成计量偏差的主要原因</p>
<p>1.计量仪表本身性能</p>
<p>（1）直管段</p>
<p>直管段的长度是否标准合格影响到计量仪表的本身性能，因为测量结果受限于到流体介质的流动状态，故在流量计的前后部位，应有足够长切合格的直管段，以保证介质的稳定流动。一般地，表前直管段不小于5D，表后直管段不小于1D。</p>
<p>&nbsp;</p>
<p>（2）流量范围</p>
<p>由于规格不同，所以流量计的流量范围也不同，同时，流量计无法检测到低于下限的流量，也很难保证其精度；同时，当气量偏高时，超过标准，会造成损失压力，脉冲丢失，遗漏计量等等，这种情况下，要想保证其精度，简直是难上加难。</p>
<p>&nbsp;</p>
<p>（3）压力</p>
<p>压力的检测对气体的准确测量起着决定性的作用，检测点的压力与相对误差成反比，压力越高，相对误差就会越来越小，因此，在选择流量计时，要充分考虑到工况的高压力，依次来选择合适的传感器量程。</p>
<p>&nbsp;</p>
<p>如何保证旋进旋涡流量计使用精度：</p>
<p>为此必须落实三个选型参数，即近期和远期的及常用流量(主要用于选定流量计公称通径)、被测介质的设计压力(主要用于选定仪表的公称压力等级)、实际工作压力(主要用于选定流量计压力传感器的压力等级)。</p>
<p>（1）当已知被测流量为工况体积流量时，可直接按表中的流量范围选取适配的公称通径；</p>
<p>（2）当已知被测流量为标况条件下的体积流量时，应先将标况体积流量换算为工况体积流量，再按技术参数表中的流量范围选取相应的公称通径；</p>
<p>（3）当两种口径流量计均能覆盖低和高体积流量时，在压损允许下，应尽量选小口径；</p>
<p>（4）勿使实际小流量Qmin低于所选公称通径流量计的流量下限；</p>
<p>（5）流量范围、公称压力有特殊要求时可协议订货。</p>
<p><a href="https://www.zhanfengdesign.com/2899/">如何确保旋进旋涡流量计的使用精度</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>旋进旋涡流量计波动原因分析</title>
		<link>https://www.zhanfengdesign.com/2898/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Sat, 07 Oct 2023 09:28:06 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>旋进旋涡流量计波动主要是由脉动流现象和超 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/2898/">旋进旋涡流量计波动原因分析</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p>旋进旋涡流量计波动主要是由脉动流现象和超量程、流程频繁波动引起的。管道中气体流速和压力发生突然变化，造成脉动流，引起差压波动，当节流装置出现明显的脉动流时，<a href="https://www.zhanfengdesign.com/xjxwllj/">旋进旋涡流量计</a>计量可能产生较大误差，脉动流引起的误差大可达20%～30%。下面分析一下引起旋进旋涡流量计波动的原因有哪些：</p>
<p>&nbsp;</p>
<p>1.旋进旋涡流量计机械振动</p>
<p>管道的强烈机械振动会对流量计产生影响，VN系列流量计的抗机械振动能力强，但在有强烈机械震动的场合，VN系列流量计的度可能会降低。</p>
<p>&nbsp;</p>
<p>2.旋进旋涡流量计电磁干扰</p>
<p>无论是标定设定参数，还是厂家设定参数，均存于旋进旋涡流量计积算仪中的电可擦可编程只读存储器(EEPROM)中，在断电的情况下也可长期保存，当遇到强烈的电磁干扰冲击或其他较强干扰时，这些参数也存在部分变化的可能性。</p>
<p>&nbsp;</p>
<p>3.气体杂质</p>
<p>气体分离不彻底，气质含有较大颗粒或有较长纤维杂物时会堵塞流量计，影响流量计传感器对涡流旋转频率的测量，使流量计的下降;另外，分离不彻底的天然气气质中含有液体，会腐蚀流量计的各个连接部位和传感器，连接部位使用的密封垫片腐蚀后会造成流量计的局部渗漏，影响了流量计的计量。</p>
<p><a href="https://www.zhanfengdesign.com/2898/">旋进旋涡流量计波动原因分析</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>旋进旋涡流量计的安装方法与接线图</title>
		<link>https://www.zhanfengdesign.com/2835/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Wed, 12 Jul 2023 11:46:17 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>旋进旋涡流量计如果安装保养不当，不仅影响 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/2835/">旋进旋涡流量计的安装方法与接线图</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p>旋进旋涡流量计如果安装保养不当，不仅影响测量的精度，严重的时候还会使仪表损坏；在搬动<a href="https://www.zhanfengdesign.com/xjxwllj/">旋进旋涡流量计</a>的时候，应该将吊索套在流量计法兰两端的颈部位置上，切勿在测量管内套入管棒来进行吊装，同时应当防止旋进旋涡流量计接线插座受碰撞而损坏。</p>
<p>&nbsp;</p>
<p>旋进旋涡流量计没有机械可动部件，体积小，耐腐蚀，性能稳定;可直接显示介质的工作压力、温度、流量以及标准状态下的气量;量程范围宽，计量误差小等优点，现已广泛用于油气井的生产计量和天然气的销售计量中。在多年来的现场应用中，我们认为该流量计于较为干净的干气计量，渐成为中小用气计量的计量仪表。要保证旋进旋涡流量计计量准确，减少计量误差。</p>
<p>&nbsp;</p>
<p>一、旋进旋涡流量计安装要求</p>
<p>1、旋进旋涡流量计安装时，严禁在其进出口法兰处直接进行电焊，以免烧坏流量计内部零件。</p>
<p>2、对于新安装或检修后的管道务必进行清扫，去除管道中的杂物后方能安装流量计。</p>
<p>3、流量计应安装在便于维修、无强电磁场干扰、无强烈机械振动以及热辐射影响的场所；</p>
<p>4、不宜用在流量频繁中断和有强烈脉动流或压力脉动的场合；</p>
<p>5、在室外安装时，上部应有遮盖物，以防雨水浸入和烈日曝晒影响流量计使用寿命；</p>
<p>6、流量计可任意角度安装，流体的流向应与流量计上标识的流向一致；</p>
<p>7、在管道施工中，应考虑安装伸缩管或波纹管，以免对流量计造成严重的拉伸或断裂；</p>
<p>8、流量计应与管道同轴安装，并防止密封片和黄油进入管道内腔；</p>
<p>9、采用外电源时，流量计必须有可靠接地，不得与强电系统共用地线，在管道安装或检修时，不得把电焊系统的地线与流量计搭接。</p>
<p>10、为了不影响流体正常输送和便于维护，要求按图所示安装旁通管道，并保证前≥3DN、后≥1DN的直管段；</p>
<p><img decoding="async" title="1689133647202829.jpg" src="/static/upload/image/20230712/1689133647202829.jpg" alt="xuanxing3.jpg/" /></p>
<p>&nbsp;</p>
<p>二、旋进旋涡流量计安装直管段要求</p>
<p>根据旋进旋涡流量计的工作原理和流量计对上、下游直管段要求，对各种上游阻力件，建议采用如下图所列的前后直管段长度，且保持直管段内壁光滑平直。</p>
<p><img decoding="async" title="1689133654148982.jpg" src="/static/upload/image/20230712/1689133654148982.jpg" alt="xuanxing4.jpg/" /></p>
<p>&nbsp;</p>
<p>三、智能旋进旋涡流量计两线制电流接线方法</p>
<p><img decoding="async" title="1689133662209267.jpg" src="/static/upload/image/20230712/1689133662209267.jpg" alt="xuanxing5.jpg/" /></p>
<p>&nbsp;</p>
<p>四、智能旋进旋涡流量计三线制电流输出接线方法</p>
<p><img decoding="async" title="1689133670184371.jpg" src="/static/upload/image/20230712/1689133670184371.jpg" alt="xuanxing6.jpg/" /></p>
<p>&nbsp;</p>
<p>五、智能旋进旋涡流量计脉冲输出接线方法</p>
<p><img decoding="async" title="1689133677316574.jpg" src="/static/upload/image/20230712/1689133677316574.jpg" alt="xuanxing7.jpg/" /></p>
<p>&nbsp;</p>
<p>六、智能旋进旋涡流量计当量输出接线方法</p>
<p><img decoding="async" title="1689133684210498.jpg" src="/static/upload/image/20230712/1689133684210498.jpg" alt="xuanxing8.jpg/" /></p>
<p>&nbsp;</p>
<p>七、报警输出接线方法</p>
<p><img decoding="async" title="1689133696217972.jpg" src="/static/upload/image/20230712/1689133696217972.jpg" alt="xuanxing9.jpg/" /></p>
<p>&nbsp;</p>
<p>八、通信输出接线方法</p>
<p><img decoding="async" title="1689133711140913.jpg" src="/static/upload/image/20230712/1689133711140913.jpg" alt="xuanxing10.jpg/" /></p>
<p><a href="https://www.zhanfengdesign.com/2835/">旋进旋涡流量计的安装方法与接线图</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>旋进旋涡流量计的应用场合</title>
		<link>https://www.zhanfengdesign.com/2834/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Wed, 12 Jul 2023 11:32:18 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>旋进旋涡流量计在原油生产与储运过程中，应 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/2834/">旋进旋涡流量计的应用场合</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p>旋进旋涡流量计在原油生产与储运过程中，应用较为广泛的一种速度式流量计，由于其无可动部件，具备温度压力修正功能，在恶劣的现场条件下能够测量出天然气标准流量值，具有较高的性价比，能够满足企业内部生产经营管理要求。</p>
<p>&nbsp;</p>
<p>目前在石油、石化系统，该流量计主要如下场合使用：</p>
<p>（1）用于原油生产过程中的伴生气计量，主要安装于油液分离器的上部的天然气出口部位，经过分离的天然气经计量后，又混入集输管线，输往中转站。由于伴生气中含有一定量的轻烃、二氧化碳、水等介质，随着温度、压力的变化，呈饱和状态的上述组分会从天然气中呈凝析出来，在含量&lt;15%时，计量准确度≤±5%，因此，该流量计在原油生产现场的应用较多，占气体流量计的95%。</p>
<p>（2）用于原油中转、集输站库经过油气水三相分离器处理后，天然气储运计量。在天然气轻烃、二氧化碳、水等介质含量&lt;5%情况下，计量准确度≤±3%。</p>
<p>（3）用于原油集输站库生产用锅炉、热水加热炉等耗能设施的天然气消耗计量，经过上述加热设施产生的蒸汽和热水，作为载能工质用于原油储运中的伴热保温。因天然气较为纯净，计量准确度≤±2%。</p>
<p>&nbsp;</p>
<p>由于<a href="https://www.zhanfengdesign.com/xjxwllj/">旋进旋涡流量计</a>是一种速度式流量计，在流体通过节流断使旋涡流动加速，会产生压力损失，因此，在使用中应避免一下问题的出现：</p>
<p>（1）测量介质精良保证为单一牛顿体，如果原油及微量颗粒杂质较多，应在流量计之前分离、过滤器，否则会造成测量值大于实际值。</p>
<p>（2）流量计的选用应该根据介质的实际流量，而非安装管线的直径，这一点非常重要。</p>
<p>（3）要避免因压力传感器的量程选择，和温度、压力传感器误差变化产生的计量误差，由于目前使用的智能旋进旋涡流量计的压力传感器量程为2.0Mpa，在气体实际量程压力≤±0.3Mpa时，会使标准状态下的天然气计量误差增大。同时，由于油田使用的智能旋进旋涡流量计，大部分用于非贸易计量交接，流量计未能按期检定，导致压力、温度传感器产生零点飘移，造成天然气寄来能够误差增大，因此必须对流量计按期进行检定于校对。</p>
<p><a href="https://www.zhanfengdesign.com/2834/">旋进旋涡流量计的应用场合</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>旋进旋涡流量计有哪些优缺点</title>
		<link>https://www.zhanfengdesign.com/2811/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Fri, 16 Jun 2023 10:04:55 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>旋进旋涡流量计流量计是一种气体流量计，当 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/2811/">旋进旋涡流量计有哪些优缺点</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p>旋进旋涡流量计流量计是一种气体流量计，当气体介质进入流量传感器入口时，螺旋形叶片强迫流体进行旋转运动，于是在旋涡发生体中心产生旋涡流，旋涡流在文丘利管中旋进，到达收缩段突然节流使旋涡流加速，当旋涡流进入扩散段后，因回流作用强迫进行旋进式二次旋转。此时旋涡流的旋转频率与介质流速成正比，并为线性。<a href="https://www.zhanfengdesign.com/xjxwllj/">旋进旋涡流量计</a>两个压电传感器检测的微弱电荷信号同时经前置放大器放大、滤波、整形后变成两路频率与流速成正比的脉冲信号。流量积算仪中的处理电路对两路的脉冲信号进行比较与判别，剔除干扰信号，而对正常的流量信号进行计数处理。智能型旋进旋涡流量计主要由旋涡发生体、壳体、旋涡检测组件、除旋整流器、温度接口、压力接口及信号输出接口等组成。</p>
<p>&nbsp;</p>
<p>旋进旋涡流量计具有流量、温度、压力检测功能于一体，并能进行温度、压力、压缩因子自动补偿，是石油、化工、电力、冶金等行业用于气体计量的理想仪表。</p>
<p>&nbsp;</p>
<p>旋进旋涡流量计的优点</p>
<p>1、旋进旋涡流量计内置式压力、温度、流量传感器，安全性能高,结构紧凑，外形美观。</p>
<p>2、就地显示温度、压力、瞬时流量和累积流量。</p>
<p>3、旋进旋涡流量计采用新型信号处理放大器和*的滤波技术，有效地剔除了压力波动和管道振动所产生的干扰信号，大大提高了流量计的抗干扰能力，使小流量具有出色的稳定性。</p>
<p>4、特有时间显示及实时数据存储之功能，无论什么情况，都能保证内部数据不会丢失,可*性保存。</p>
<p>5、整机功耗极低,能凭内电池长期供电运行,是理想的无需外电源就地显示仪表。</p>
<p>6、防盗功能可靠，具有密码保护,防止参数改动。</p>
<p>7、旋进旋涡流量计的表头可180度随意旋转，安装方便。</p>
<p>&nbsp;</p>
<p>旋进漩涡流量计的缺点</p>
<p>1、由于它是一种速度式流量计，即旋涡分离的稳定性受流速影响，故它对直管段有一定要求。</p>
<p>2、测量液体时，上限流速受压损和气穴现象限制。</p>
<p>3、测量气体时，上限流速受介质可压缩性变化的限制，下限流速受雷诺数和传感器灵敏度的限制。</p>
<p>4、对管道振动较为敏感。</p>
<p><a href="https://www.zhanfengdesign.com/2811/">旋进旋涡流量计有哪些优缺点</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>旋进旋涡流量计与涡街流量计的区别</title>
		<link>https://www.zhanfengdesign.com/2810/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Fri, 16 Jun 2023 09:59:18 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>涡街流量计与旋进旋涡流量计，都是在工业自 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/2810/">旋进旋涡流量计与涡街流量计的区别</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p>涡街流量计与旋进旋涡流量计，都是在工业自动化领域中应用比较广泛的仪表。</p>
<p>&nbsp;</p>
<p>涡街流量计是一种速度式流量仪表，具有广泛用途。可对液体、蒸汽和绝大多数气体的流量计量、测量和控制。广泛用于石油、化工、纺织、冶金、食品、造纸、制药、能源等行业。</p>
<p>&nbsp;</p>
<p><a href="https://www.zhanfengdesign.com/xjxwllj/">旋进旋涡流量计</a>是集压力、温度、流量传感器于一体，直接显示标准状态下介质体积的流量计。它通过内部温度传感器、压力传感器和流量传感器检测相应参数，来实现气体介质标准流量的计量，广泛用于石油、化工、冶金、城市燃气输配管网等领域的气体计量。</p>
<p>&nbsp;</p>
<p>1、结构不同</p>
<p>涡街流量计和旋进旋涡流量计的发生体都是不可动部件，通常都称之为漩涡发生体，但两者的漩涡发生体是不同的，涡街的旋涡发生体是三角柱型的，旋进旋涡的旋涡发生体类似于涡轮的叶轮。</p>
<p>&nbsp;</p>
<p>2、测量原理不同</p>
<p>涡街流量计原理是在流体中设置三角柱型漩涡发生体，气体流经旋涡发生体，从两侧交替的产生有规则的漩涡，这种旋涡称为卡门涡街，通过测量涡街发生的频率来计算测量介质流量。</p>
<p><img decoding="async" title="1686880883949223.jpg" src="/static/upload/image/20230616/1686880883949223.jpg" alt="zhaopian21.jpg/" /></p>
<p>漩涡发生体示意图</p>
<p>&nbsp;</p>
<p>旋进旋涡流量计测量原理是当流体通过由螺旋形叶片组成的旋涡发生器后，流体被迫绕着发生体轴剧烈旋转，形成旋涡。当流体进入扩散段时，旋涡流受到回流的作用，开始作二次旋转，形成陀螺式的涡流进动现象。两者都是产生旋涡，涡街流量计的漩涡是两侧交替产生的，旋进旋涡流量计的漩涡是陀螺式的。</p>
<p><img decoding="async" title="1686880908864768.jpg" src="/static/upload/image/20230616/1686880908864768.jpg" alt="xuanxing2.jpg/" /></p>
<p>旋进旋涡流量计一次表部分工作原理图</p>
<p>&nbsp;</p>
<p>3、所测介质不同</p>
<p>涡街流量计可测量气体、液体和蒸汽，旋进旋涡流量计只可以测量气体。</p>
<p>&nbsp;</p>
<p>4、测量管径</p>
<p>涡街流量计测量管径范围大于旋进旋涡流量计管径。同等管径测量气体时流量范围不同，根据现场实际应用情况选择哪款流量计更适合。</p>
<p><a href="https://www.zhanfengdesign.com/2810/">旋进旋涡流量计与涡街流量计的区别</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>旋进旋涡流量计常见故障处理</title>
		<link>https://www.zhanfengdesign.com/1455/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Tue, 27 Apr 2021 09:26:40 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>旋进旋涡流量计主要组成部分是由内置式压力 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1455/">旋进旋涡流量计常见故障处理</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>旋进旋涡流量计主要组成部分是由内置式压力、温度、流量传感器和一个完全由电子元件组成的流量积算仪，该类型检测仪表能有效的剔除压力波动和管道震动所产生的干扰信号，提高流量计的抗干扰能力。</div>
<div></div>
<div><a href="https://www.zhanfengdesign.com/xjxwllj/">气体旋进旋涡流量计</a>的常见故障有</div>
<div>（1）用户不用气时，流量计还是不停运转，即工程技术人员常说的蹦字现象。针对这种故障处理方法是看周围是否有振动源干扰。如有消除干扰源就可解决蹦字问题；在某些情况下，适当的降低计量仪表的灵敏度也可解决该问题。</div>
<div></div>
<div>（2）用户用气时，流量计不走字。针对这种故障的处理方式是，首先看用户的用气量是否达到起步流量，如没有达到起步流量，应更换小表。如达到起步量还不走字，有可能前置放大器损坏，也有可能表头的主板损坏，后边几种情况请专业人员来维修。</div>
<div></div>
<div>（3）用户用气时，流量计量偏低，即我们所说的表走慢。出现故障的原因有三个：</div>
<div>其一，轴承磨损严重造成阻力增大，使涡轮转速变慢，造成表走慢；</div>
<div>其二，涡轮的叶片沾满了油污和炭黑，使叶轮重量增加，使转速减慢，造成表走慢；</div>
<div>其三，涡轮被打坏，造成表走慢。针对这种故障的处理方法是更换或维修、清洗仪表。</div>
<div></div>
<div>（4）用户用气时，流量计不计数。出现故障的原因有两种可能：</div>
<div>一是轴承被卡死；</div>
<div>二是流量计主板故障。</div>
<div>针对这种故障的处理方法是更换或维修流量计。</div>
<p><a href="https://www.zhanfengdesign.com/1455/">旋进旋涡流量计常见故障处理</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>旋进旋涡流量计外形尺寸</title>
		<link>https://www.zhanfengdesign.com/1454/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Tue, 27 Apr 2021 09:16:23 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>仪表外形尺寸及安装 1 旋进旋涡流量计外 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1454/">旋进旋涡流量计外形尺寸</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>仪表外形尺寸及安装</div>
<div>1 旋进旋涡流量计外形尺寸</div>
<div><a href="https://www.zhanfengdesign.com/xjxwllj/">智能旋进旋涡流量计</a>的外形尺寸见图 5，图中未注尺寸列于表 2 中，流量计采用法兰连接方式。法兰尺寸执行 GB/T9112～9113-2000 标准。</div>
<div><img decoding="async" style="width: 550px; height: 313px;" src="/uploads/allimg/210427/1-21042GGPb36.jpg" alt="旋进旋涡流量计外形图" /></div>
<div><img decoding="async" style="width: 550px; height: 432px;" src="/uploads/allimg/210427/1-21042GGT01Z.jpg" alt="旋进旋涡流量计外形尺寸表" /></div>
<div>注：以上数据仅供参考，具体以实物为准，如有技术升级，暂不另行通知</div>
<p><a href="https://www.zhanfengdesign.com/1454/">旋进旋涡流量计外形尺寸</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>旋进旋涡流量计结构与组成</title>
		<link>https://www.zhanfengdesign.com/1453/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Tue, 27 Apr 2021 07:40:55 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>旋进旋涡流量计可广泛应用于石油、化工、电 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1453/">旋进旋涡流量计结构与组成</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>旋进旋涡流量计可广泛应用于石油、化工、电力、冶金、城市供气等行业测量各种气体流量。当流体进入流量传感器时，导流叶片迫使流体产生剧烈的旋涡流。当流体进入扩散段时，旋涡流受到回流的作用，开始作二次旋转，形成陀螺式的涡流进动现象。该进动频率与流量大小成正比，不受流体物理性质和密度的影响，检测元件测得流体二次旋转进动频率就能在较宽的流量范围内获得良好的线性度。信号经前置放大器放大、滤波、整形转换为与流速成正比的脉冲信号，然后再与温度、压力等检测信号一起被送往微处理器进行积算处理，后在液晶显示屏上显示出测量结果（瞬时流量、累积流量及温度、压力数据）。</div>
<div><img decoding="async" style="width: 500px; height: 353px;" src="/uploads/allimg/210427/1-21042G54205623.jpg" alt="" /></div>
<div><a href="https://www.zhanfengdesign.com/xjxwllj/">旋进旋涡流量计</a>结构：</div>
<div>1、旋涡发生体</div>
<div>用铝合金制成，具有一定角度的螺旋叶片，它固定在壳体收缩段前部，强迫流体产生强烈的漩涡流。</div>
<div></div>
<div>2、壳体</div>
<div>本身带有法兰，并有一定形状的流体通道，根据不同的工作压力，壳体材料可采用铸铝合金或不锈钢。</div>
<div></div>
<div>3、智能流量计积算仪</div>
<div>由温度、压力检测模拟通道、流量检测数字通道以及微处理单元、液晶驱动电路和其它辅助电路组成，并配有外输信号接口。</div>
<div></div>
<div>4、温度传感器</div>
<div>以Pt100铂电阻为温度敏感元件，在一定温度范围内，其电阻值与温度成对应关系。</div>
<div></div>
<div>5、压力传感器</div>
<div>以压阻式扩散硅桥路为敏感元件，其桥臂电阻在外界压力作用下会发生预期变化，因此在一定激励电流作用下，其两个输出端的电位差与外界压力成正比。</div>
<div></div>
<div>6、压电晶体传感器</div>
<div>安装在靠近壳体扩张段的喉部，可检测出漩涡进动的频率信号。</div>
<div></div>
<div>7、消旋器</div>
<div>固定在壳体出口段，其作用是消除旋涡流，以减小对下游仪表性能的影响。</div>
<p><a href="https://www.zhanfengdesign.com/1453/">旋进旋涡流量计结构与组成</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>旋进旋涡流量计的日常维护</title>
		<link>https://www.zhanfengdesign.com/1452/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Tue, 27 Apr 2021 07:34:30 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>旋进旋涡流量计广泛应用于石油、化工、电力 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1452/">旋进旋涡流量计的日常维护</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>旋进旋涡流量计广泛应用于石油、化工、电力、冶金、城市供气等行业测量各种气体流量，是目前油田和城市天然气输配计量和贸易计量的产品。日常维护中应该注意的问题：</div>
<div></div>
<div>1.在冬天的用气高峰期，有时流量计可能会出现超出其计量范围的现象，此时流量计节流现象严重，前后静压差大，由理想气体状态方程可知，气体压力降低，温度也相应降低，此时易出现流量计后端结冰现象，造成管线堵塞。</div>
<div></div>
<div>2.加强<a href="https://www.zhanfengdesign.com/xjxwllj/">旋进旋涡流量计</a>的日常检测和维护。从位于210配气站的作为贸易计量的流量计A至位于我公司大山铺配气站的参比流量计B的管线长度约为0.8km（型号均为TDS-50B），管线为新投入使用管线。在正常情况下，两台流量计每天的误差在2.5%以内，但在一段时间内，两台流量计输差达到了7%。两台流量计的检定参数均在有效期内，且两台流量计的管线之间无分管及其他节流装置，影响压缩因子的相对密度、N2、CO2含量等参数也设置相同。经过分析后，发现流量计B压力显示（绝压）仅仅比其周围压力表（表压）高50kPa，初步断定是流量计压力传感器出现问题；把流量计B拆下吹扫后，恢复正常，由此认为可能是由于流量计B的压力传感器上被微尘或油污堵上，导致压力传感器失灵造成的。</div>
<div></div>
<div>3.定期检查智能旋进旋涡流量计的旋涡发生器。如果旋涡发生器磨损较大，可能导致流经流量计的天然气无法正常产生旋涡脉冲，进而导致计量结果比真实值偏小。因此，为避免天然气计量中发生此类问题，应在流量计前段加装过滤器，并有规律地对过滤器进行清洗。</div>
<div></div>
<div>4.注意内部维护。如果由于气质脏污或其它原因需要对仪表的测量腔体及其构件进行定期检查或清洗，那么有一点则必须特别注意：对于同规格的旋进旋涡流量计，其旋涡发生体、导流体等核心组件不能互换，否则，须重新标定仪表计量系数并对其配带的温度及压力传感器进行系统校正。</div>
<p><a href="https://www.zhanfengdesign.com/1452/">旋进旋涡流量计的日常维护</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>旋进旋涡流量计怎么使用</title>
		<link>https://www.zhanfengdesign.com/1414/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Mon, 22 Mar 2021 14:09:23 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>旋进旋涡流量传感器是目前广泛应用于石油、 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1414/">旋进旋涡流量计怎么使用</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>旋进旋涡流量传感器是目前广泛应用于石油、化工、电力、冶金、城市供气等行业各种气体流量测量的传感器，正确使用旋进旋涡流量传感器要遵循以下五点要求，这样才能保证测量的准确性。</div>
<div></div>
<div>一、仪表选型非常之重要</div>
<div>在已经选定了流量传感器种类的情况下，紧接着就是对流量传感器规格及其配套元件的选择至关重要。一句话，选好才能用好。为此，在选型过程中应把握住两条基本原则;即：一要保证使用精度，二要保证生产安全。要做到这一点，就必须落实三个选型参数，即近期和远期的最大、最小及常用瞬时流量、被测介质的设计压力、工作压力。</div>
<div></div>
<div>二、进行用前标校</div>
<div>一方面，考虑到目前对这类流量传感器的现场检定还存在这样那样的困难。另外，如果购置的意图又是准备将该这种流量传感器运用于比较重要的计量场合，比如大流量的贸易计量或计量纠纷比较突出的测量点，并且运用现场也不具备流量在线标校条件，那么在这种情况下，仅凭购买时由生产厂家提供的一纸出厂合格证明就轻易判定流量传感器全部性能合格，那就有些为时过早。因此，为了确保流量传感器在今后的工作过程中其测量结果的可靠与准确，就有必要在正式安装前将流量传感器送往具有这方面检定能力及资质的部门进行一次全流量范围内的系统检定。</div>
<div></div>
<div>三、搞好工艺安装</div>
<div>虽然该种流量传感器对工艺安装及使用环境没有太多的特殊要求，但任何一类流量测量仪表都有这样一种共性，即尽可能避免振动及高温环境随离流态干扰元件、保持流量传感器前后直管段内壁光滑平直、保证被测介质为洁净的单相流体等。</div>
<div></div>
<div>四、加强后期管理</div>
<div><a href="https://www.zhanfengdesign.com/xjxwllj/">旋进旋涡流量计</a>虽然具有多种自动处置功能和微功耗的特点，但投运之后仍需加强管理。比如，为了保证流量传感器长期工作的准确性、可靠性，就应定期进行系统标校、抄录表头数据、更换介质参数以及不定期查看电池状况、检查流量传感器系数及铅封等。</div>
<div></div>
<div>五、注意内部维护</div>
<div>如果由于气质脏污或其它原因需要对流量传感器的测量腔体及其构件进行定期检查或清洗，那么有一点则必须特别注意：对于同规格的旋进旋涡流量传感器，其旋涡发生体、导流体等核心组件不能互换，否则，须重新标定仪表计量系数并对其配带的温度及压力传感器进行系统校正。</div>
<div>流量传感器的选型、标校、工艺安装、后期管理和内部维护这五点要求如果把握得好的话，以后传感器使用就会减少很多的问题，这对于连续生产型厂家尤为重要。</div>
<p><a href="https://www.zhanfengdesign.com/1414/">旋进旋涡流量计怎么使用</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>旋进旋涡流量计特点</title>
		<link>https://www.zhanfengdesign.com/1405/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Thu, 18 Mar 2021 13:36:01 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>旋进旋涡流量计主要特点 1.无机械可动部 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1405/">旋进旋涡流量计特点</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>
	<strong>旋进旋涡流量计主要特点</strong>
	 </div>
<div>
	1.无机械可动部件，不易腐蚀，稳定可靠，寿命长，长期运行无须特殊维护；
	 </div>
<div>
	2.采用 16 位计算机芯片，集成度高，体积小，性能好，整机功能强；
	 </div>
<div>
	3.智能型流量计集流量探头、微处理器、压力、温度传感器于一体, 采取内置式组合,使结构更加紧凑，可直接测量流体的流量、压力和温度，并自动实时跟踪补偿和压缩因子修正；
	 </div>
<div>
	4.采用双探头检测技术及新型传感器处理技术、合理的安装方式，大大地提高信号强度，使传感器能准确地检测出信号，并抑制由管线振动引起的干扰；
	 </div>
<div>
	5.采用国内领先的智能抗震技术，有效的抑制了震动和压力波动造成的干扰信号；
	 </div>
<div>
	6.采用汉字点阵显示屏，显示位数多，读数直观方便，可直接显示工作状态下的体积流量、标准状态下的体积流量、总量，以及介质压力、温度等参数；
	 </div>
<div>
	7.转换器可输出频率脉冲、4～20mA 模拟信号，并具有 RS485 接口，可直接与计算机联网，传输距离可达 1.2km；
	 </div>
<div>
	8.多物理量参数报警输出，可由用户任选其中之一；
	 </div>
<div>
	9.压力、温度信号为传感器输入方式，互换性强；
	 </div>
<div>
	10.整机功耗低，可用内置电池供电，也可外接电源。</div>
<p><a href="https://www.zhanfengdesign.com/1405/">旋进旋涡流量计特点</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>旋进旋涡流量计安装要求</title>
		<link>https://www.zhanfengdesign.com/1404/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Thu, 18 Mar 2021 13:22:56 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>旋进旋涡流量计仪表外形尺寸及安装 4.1 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1404/">旋进旋涡流量计安装要求</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div><strong>旋进旋涡流量计仪表外形尺寸及安装</strong></div>
<div>4.1 流量计外形尺寸</div>
<div>流量计的外形尺寸见图 5，图中未注尺寸列于表 2 中，流量计采用法兰连接方式。法兰尺寸执行 GB/T9112～9113-2000 标准。</div>
<div><img decoding="async" style="width: 550px; height: 313px;" src="/uploads/allimg/210318/1-21031R12402192.jpg" alt="" /></div>
<div><img decoding="async" style="width: 550px; height: 432px;" src="/uploads/allimg/210318/1-21031R124143R.jpg" alt="" /></div>
<div>注：以上数据仅供参考，具体以实物为准，如有技术升级，暂不另行通知</div>
<div>4.2 流量计安装</div>
<div>4.2.1 流量计的安装</div>
<div>1.流量计安装时，严禁在其进出口法兰处直接进行电焊，以免烧坏流量计内部零件。</div>
<div>2.对于新安装或检修后的管道务必进行清扫，去除管道中的杂物后方能安装流量计。</div>
<div>3.流量计应安装在便于维修、无强电磁场干扰、无强烈机械振动以及热辐射影响的场所；</div>
<div>4.流量计不宜用在流量频繁中断和有强烈脉动流或压力脉动的场合；</div>
<div>5.流量计室外安装时，上部应有遮盖物，以防雨水浸入和烈日曝晒影响流量计使用寿命；</div>
<div>6.流量计可任意角度安装，流体的流向应与流量计上标识的流向一致；</div>
<div>7.在管道施工中，应考虑安装伸缩管或波纹管，以免对流量计造成严重的拉伸或断裂；</div>
<div>8.流量计应与管道同轴安装，并防止密封片和黄油进入管道内腔；</div>
<div>9.采用外电源时，流量计必须有可靠接地，不得与强电系统共用地线，在管道安装或检修时，不得把电焊系统的地线与流量计搭接。</div>
<div>10.为了不影响流体正常输送和便于维护，要求按图 6 所示安装旁通管道，并保证前≥3DN、 后≥1DN 的直管段；</div>
<div><img decoding="async" style="width: 550px; height: 282px;" src="/uploads/allimg/210318/1-21031R12433462.jpg" alt="" /></div>
<div>4.2.2 直管段要求</div>
<div>根据<a href="https://www.zhanfengdesign.com/xjxwllj/">旋进旋涡流量计</a>的工作原理和流量计对上、下游直管段要求，对各种上游阻力件，建议采用如图 7 所列的前后直管段长度，且保持直管段内壁光滑平直。</div>
<div><img decoding="async" style="width: 550px; height: 495px;" src="/uploads/allimg/210318/1-21031R1244E62.jpg" alt="" /></div>
<div>4.2.3 安装注意事项</div>
<div>1.传感器按流向标志可在垂直、水平或任意倾斜位置上安装；</div>
<div>2.当管线较长或距离振动源较近时，应在流量计的上、下游安装支撑，以消除管线振动的影响；</div>
<div>3.传感器的安装地点应有足够的空间，以便于流量计的检查和维修，并应满足流量计的环境要求；</div>
<div>4.应避免外界强磁场的干扰；</div>
<div>5.在室外安装使用时，应有遮盖物，避免烈日曝晒与雨水浸蚀，影响仪表使用寿命；</div>
<div>6.管线试压时，应注意智能型流量计所配置压力传感器的压力测量范围,以免过压损坏压力传感器；</div>
<div>7.应注意安装应力的影响，安装流量计上游和下游管道应同轴，否则会产生剪切应力。安装流量计的位置应考虑密封垫片的厚度，或在下游安装一个弹性伸缩节；</div>
<div>8.安装流量计之前应先清除管道中的焊渣等杂物；</div>
<div>9.投入运行时，应缓慢开启流量计上、下游阀门，以免瞬间气流过急而冲坏起旋器；</div>
<div>10.当流量计需要有信号远传时，应严格按“工作电源”要求接入外电源（8～24）VDC，严禁在信号输出口直接接入 220VAC 或 380VAC 电源；</div>
<div>11.用户不得自行更改防爆系统的接线方式和任意拧动各个输出引线接头；</div>
<div>12.流量计运行时，不允许随意打开后盖改动仪表参数，否则影响流量计的正常工作；</div>
<div>13.定时检查流量计法兰处的泄漏情况。</div>
<div>4.2.4 内置电池的使用及更换</div>
<div>1.电池电量显示</div>
<div>当电池显示仅剩一格时，要求用户在一个月内更换电池；只显示电池外形符号时，则电池电量已耗尽，必须立即更换电池。</div>
<div>2.电池的更换方法</div>
<div>打开智能流量积算仪的后盖，松开电池盖板上的三颗螺钉，拔下电池插座，取出电池，换好新电池后重新安装。</div>
<div>4.2.5 防爆场所安装要求</div>
<div>1.流量计应有可靠的接地，防爆接地不应与强电系统的保护接地共用；</div>
<div>2.现场测试电源时，不允许使用交流电源接地；</div>
<div>3.在任何情况下，用户不得自行更改防爆电路、元器件和防爆型式；</div>
<div>4.必须先切断外接电源再打开转换器盖子。</div>
<p><a href="https://www.zhanfengdesign.com/1404/">旋进旋涡流量计安装要求</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>旋进旋涡流量计选型指南</title>
		<link>https://www.zhanfengdesign.com/1398/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Mon, 15 Mar 2021 12:36:22 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>旋进旋涡流量计技术性能及选型指南 3.1 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1398/">旋进旋涡流量计选型指南</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div><a href="https://www.zhanfengdesign.com/xjxwllj/">旋进旋涡流量计</a>技术性能及选型指南</div>
<div>3.1 执行标准</div>
<div>JJG198-1994《速度式流量计》计量检定规程</div>
<div>3.2 精准度等级</div>
<div>在规定的流量范围内和工作条件下流量计的精确度等级为 1.0 级和 1.5 级。</div>
<div>3.3 流量计参数</div>
<div><img decoding="async" style="width: 550px; height: 371px;" src="/uploads/allimg/210315/1-210315203J02V.jpg" alt="" /></div>
<div>注：准确度：为温度、压力修正后的系统精度</div>
<div>3.4 标准状态条件</div>
<div>P=101.325KPa，T=293.15K</div>
<div>3.5 使用环境条件</div>
<div>环境温度：-30℃～+65℃</div>
<div>相对湿度：5%～95%</div>
<div>介质温度：-20℃～+80℃</div>
<div>大气压力：86KPa～106KPa</div>
<div>3.6 工作电源及信号输出</div>
<div>3.6.1 工作电源</div>
<div>A．外电源：＋24VDC±15%，纹波＜5％，适用于 4～20mA 输出、脉冲输出、报警输出、RS-485 等；</div>
<div>B．内电源：1 组 3.6V 锂电池（ER26500），当电压低于 3.0V 时，出现欠压指示。</div>
<div>3.6.2 整机功耗</div>
<div>A．外电源：&lt;2W;</div>
<div>B．内电源：平均功耗 1mW，可连续使用两年以上。</div>
<div>3.6.3 脉冲输出方式</div>
<div>工况脉冲信号，直接将流量传感器检测的工况脉冲信号经光耦隔离放大输出，高电平≥20V，低电平≤1V；</div>
<div>定标脉冲信号，与 IC 卡阀门控制器配套，高电平幅度≥2.8V，低电平幅度≤0.2V，单位脉冲代表体积量可设定范围：0.001m3~100m3。单选择该值时必须注意：定标脉冲信号频率应≤1000Hz。</div>
<div>定标脉冲信号，经光耦隔离放大输出，高电平≥20V，低电平≤1V。</div>
<div>3.6.4 RS-485 通信（光电隔离），可实现以下功能：</div>
<div>A．采用 RS-485 接口，可直接与上位机或二次表联网，远传显示介质的温度、压力和经温度、压力补偿后的标准体积流量和标准体积总量；</div>
<div>B．由 RS-485 接口与 HW-Ⅰ数据采集器配套，可组成电话网络通信系统，一台数据采集器可带 15 台流量计；</div>
<div>C．由 RS-485 接口与 HW-Ⅱ数据采集器配套，可组成宽带网络通信系统，由 INTERNET 传输数据，一台数据采集器可带 8 台流量计。</div>
<div>3.6.5 4～20mA 标准电流信号（光电隔离）</div>
<div>与标准体积流量成正比，4mA 对应 0 m3/h， 20 mA 对应最大标准体积流量（该值可在一级菜单中进行设置），制式：两线制或三线制，流量计可根据所插电流模块自动识别，并正确输出。</div>
<div>3.6.6 控制信号输出</div>
<div>A.下限报警信号（LP）：光电隔离，高低电平报警，报警电平可设定，工作电压＋12V~+24V，最大负载电流 50mA；</div>
<div>B.上限报警信号（UP）：光电隔离，高低电平报警，报警电平可设定，工作电压＋12V~+24V，最大负载电流 50mA；</div>
<div>C.关阀报警输出（BC 端，IC 卡控制器用）：逻辑门电路输出，正常输出低电平，幅度≤0.2V；报警输出高电平，幅度≥2.8V,负载电阻≥100kΩ；</div>
<div>D.电池欠压报警输出（BL 端，IC 卡控制器用）：逻辑门电路输出，正常输出低电平，幅 度≤0.2V；报警输出高电平，幅度≥2.8V,负载电阻≥100kΩ；</div>
<div>3.7 现场显示功能</div>
<div>A.积算仪显示面板上实时显示工况（或标况）下的温度、压力、瞬时流量、累计流量；</div>
<div>B.报警功能：流量上下限、温度上下限、压力上下限报警，报警方式：字符闪烁。</div>
<div>3.8 防爆型式与等级</div>
<div>隔爆型：其防爆标志为 ExdIIBT4、ExdIICT4-T6(不含乙炔）；</div>
<div>本安型：其防爆标志为 ExiaIICT4</div>
<div>3.9 防护等级</div>
<div>IP65</div>
<div>3.10 压力损失</div>
<div>流量计实际压力损失计算公式如下：</div>
<div><img decoding="async" style="width: 337px; height: 50px;" src="/uploads/allimg/210315/1-210315203P4O6.jpg" alt="" /></div>
<div>式中：</div>
<div>ΔP1&#8211;流量计实际压力损失（KPa）；</div>
<div>ρ&#8211;被测介质密度(kg/m3);</div>
<div>ΔP&#8211;介质为干空气时流量计的压力损失（KPa）。其特性曲线见图 4</div>
<div><img decoding="async" style="width: 550px; height: 483px;" src="/uploads/allimg/210315/1-210315203Q9101.jpg" alt="" /></div>
<div>3.11 电器接口</div>
<div>内螺纹 M20*1.5</div>
<div>3.12 选型指南</div>
<div>3.12.1 选型条件</div>
<div>用户订货时应根据管道公称压力、最高工作压力、工作温度、流量范围、环境条件等选择合适的流量计型号和规格。</div>
<div>3.12.2 合理选型</div>
<div>A、用户提供的被测流量为工况流量时，可直接依据表 2 选取相应通径的流量计；</div>
<div>B、用户提供的被测流量为标况流量时，应将标况流量换算为工况流量，选取相应通径的流量计。</div>
<div>换算公式：</div>
<div><img decoding="async" style="width: 435px; height: 392px;" src="/uploads/allimg/210315/1-210315203S2a1.jpg" alt="" /></div>
<p><a href="https://www.zhanfengdesign.com/1398/">旋进旋涡流量计选型指南</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>旋进旋涡流量计说明书</title>
		<link>https://www.zhanfengdesign.com/1397/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Mon, 15 Mar 2021 12:29:20 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>一、产品特点、用途和适用范围 很高兴您购 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1397/">旋进旋涡流量计说明书</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>一、产品特点、用途和适用范围</div>
<div>很高兴您购买本款<a href="https://www.zhanfengdesign.com/xjxwllj/">智能旋进旋涡流量计</a>，该流量计是我公司通过多年实践和学习国外先进技术开发研制的具有领先水平的新型气体流量仪表。该流量计可集流量、温度、压力检测功能于一体，并能进行温度、压力、压缩因子自动补偿，并且具有较强的抗震动和抗干扰能力，高精度和高重复性,是石油、化工、电力、冶金等行业用于气体计量的理想仪表。</div>
<div></div>
<div>1.1 产品主要特点</div>
<div>1.无机械可动部件，不易腐蚀，稳定可靠，寿命长，长期运行无须特殊维护；</div>
<div>2.采用 16 位计算机芯片，集成度高，体积小，性能好，整机功能强；</div>
<div>3.智能型流量计集流量探头、微处理器、压力、温度传感器于一体, 采取内置式组合,使结构更加紧凑，可直接测量流体的流量、压力和温度，并自动实时跟踪补偿和压缩因子修正；</div>
<div>4.采用双探头检测技术及新型传感器处理技术、合理的安装方式，大大地提高信号强度，使传感器能准确地检测出信号，并抑制由管线振动引起的干扰；</div>
<div>5.采用国内领先的智能抗震技术，有效的抑制了震动和压力波动造成的干扰信号；</div>
<div>6.采用汉字点阵显示屏，显示位数多，读数直观方便，可直接显示工作状态下的体积流量、标准状态下的体积流量、总量，以及介质压力、温度等参数；</div>
<div>7.转换器可输出频率脉冲、4～20mA 模拟信号，并具有 RS485 接口，可直接与计算机联网，传输距离可达 1.2km；</div>
<div>8.多物理量参数报警输出，可由用户任选其中之一；</div>
<div>9.压力、温度信号为传感器输入方式，互换性强；</div>
<div>10.整机功耗低，可用内置电池供电，也可外接电源。</div>
<div></div>
<div>1.2 主要用途</div>
<div>智能旋进旋涡流量计可广泛应用于石油、化工、电力、冶金、城市供气等行业测量各种气体流量，是目前油田和城市天然气输配计量和贸易计量的首选产品。</div>
<div></div>
<div>二、结构与工作原理</div>
<div>2.1 流量计结构</div>
<div>旋进旋涡流量计结构紧凑，主要由壳体、旋涡发生体、传感器（温度、压力、流量）、整流器和积算仪构成。</div>
<div><img decoding="async" style="width: 550px; height: 250px;" src="/uploads/allimg/210315/1-210315202954E7.jpg" alt="" /></div>
<div>1.旋涡发生体：用铝合金制成，具有一定角度的螺旋叶片，它固定在壳体收缩段前部，强迫流体产生强烈的旋涡流。</div>
<div>⒉壳体：本身带有法兰，并有一定形状的流体通道，根据不同的工作压力，壳体材料可采用铸铝合金或不锈钢。</div>
<div>⒊智能流量计积算仪：由温度、压力检测模拟通道、流量检测数字通道以及微处理单元、液晶驱动电路和其它辅助电路组成，并配有外输信号接口。</div>
<div>4.温度传感器：以 Pt100/pt1000 铂电阻为温度敏感元件，在一定温度范围内，其电阻值与温度成对应关系。</div>
<div>5.压力传感器：以压阻式扩散硅桥路为敏感元件，其桥臂电阻在外界压力作用下会发生预期变化，因此在一定激励电流作用下，其两个输出端的电位差与外界压力成正比。</div>
<div>6.流量传感器：安装在靠近壳体扩张段的喉部，可检测出旋涡进动的频率信号。</div>
<div>7.整流器：固定在壳体出口段，其作用是消除旋涡流，以减小对下游仪表性能的影响。</div>
<div></div>
<div>2.2 工作原理</div>
<div>流量传感器的流通剖面类似文丘利管的型式（如图 2）。在入口侧安放一组螺旋型导流叶片，当流体进入流量传感器时，导流叶片迫使流体产生剧烈的旋涡流。当流体进入扩散段时，旋涡流受到回流的作用，开始作二次旋转，形成陀螺式的涡流进动现象。该进动频率与流量大小成正比，不受流体物理性质和密度的影响，检测元件测得流体二次旋转进动频率就能在较宽的流量范围内获得良好的线性度。信号经前置放大器放大、滤波、整形转换为与流速成正比的脉冲信号，然后再与温度、压力等检测信号一起被送往微处理器进行积算处理，最后在液晶显示屏上显示出测量结果(瞬时流量、累积流量及温度、压力数据)。积算仪原理框图如图 3 所示。</div>
<div><img decoding="async" style="width: 550px; height: 201px;" src="/uploads/allimg/210315/1-21031520300DY.jpg" alt="" /></div>
<div>2.3 流量积算仪工作原理</div>
<div>流量积算仪由温度和压力检测模拟通道、流量传感器通道以及微处理器单元组成，并配有外输出信号接口，输出各种信号。流量计中的微处理器按照气态方程进行温压补偿，并动进行压缩因子修正，气态方程如下：</div>
<div><img decoding="async" style="width: 474px; height: 56px;" src="/uploads/allimg/210315/1-21031520301Q59.jpg" alt="" /></div>
<div>QN——标况下的体积流量(Nm3/h)；</div>
<div>QV——工况下的体积流量(m3/h)；</div>
<div>Pa——当地大气压力（KPa）；</div>
<div>P ——流量计取压孔测量的表压（KPa）；</div>
<div>PN——标准状态下的大气压力（101.325 KPa）；</div>
<div>TN——标准状态下的绝对温度（293.15K）；</div>
<div>T ——被测流体的绝对温度（K）；</div>
<div>ZN——气体在标况下的压缩系数；</div>
<div>Z ——气体在工况下的压缩系数；</div>
<div>注：当用钟罩或负压标定时取 ZN/Z=1，对天然气(ZN/Z)1/2=FZ为超压缩因子。按中国石油天然气总公司的标准 SY／T6143－1996 中的公式计算。</div>
<div><img decoding="async" style="width: 550px; height: 371px;" src="/uploads/allimg/210315/1-210315203029120.jpg" alt="" /></div>
<div></div>
<div>三、技术性能及选型指南</div>
<div>3.1 执行标准</div>
<div>JJG198-1994《速度式流量计》计量检定规程</div>
<div>3.2 精准度等级</div>
<div>在规定的流量范围内和工作条件下流量计的精确度等级为 1.0 级和 1.5 级。</div>
<div>3.3 流量计参数</div>
<div><img decoding="async" style="width: 550px; height: 371px;" src="/uploads/allimg/210315/1-210315203040P7.jpg" alt="" /></div>
<div>注：准确度：为温度、压力修正后的系统精度</div>
<div>3.4 标准状态条件</div>
<div>P=101.325KPa，T=293.15K</div>
<div>3.5 使用环境条件</div>
<div>环境温度：-30℃～+65℃</div>
<div>相对湿度：5%～95%</div>
<div>介质温度：-20℃～+80℃</div>
<div>大气压力：86KPa～106KPa</div>
<div>3.6 工作电源及信号输出</div>
<div>3.6.1 工作电源</div>
<div>A．外电源：＋24VDC±15%，纹波＜5％，适用于 4～20mA 输出、脉冲输出、报警输出、RS-485 等；</div>
<div>B．内电源：1 组 3.6V 锂电池（ER26500），当电压低于 3.0V 时，出现欠压指示。</div>
<div>3.6.2 整机功耗</div>
<div>A．外电源：&lt;2W;</div>
<div>B．内电源：平均功耗 1mW，可连续使用两年以上。</div>
<div>3.6.3 脉冲输出方式</div>
<div>工况脉冲信号，直接将流量传感器检测的工况脉冲信号经光耦隔离放大输出，高电平≥20V，低电平≤1V；</div>
<div>定标脉冲信号，与 IC 卡阀门控制器配套，高电平幅度≥2.8V，低电平幅度≤0.2V，单位脉冲代表体积量可设定范围：0.001m3~100m3。单选择该值时必须注意：定标脉冲信号频率应≤1000Hz。</div>
<div>定标脉冲信号，经光耦隔离放大输出，高电平≥20V，低电平≤1V。</div>
<div>3.6.4 RS-485 通信（光电隔离），可实现以下功能：</div>
<div>A．采用 RS-485 接口，可直接与上位机或二次表联网，远传显示介质的温度、压力和经温度、压力补偿后的标准体积流量和标准体积总量；</div>
<div>B．由 RS-485 接口与 HW-Ⅰ数据采集器配套，可组成电话网络通信系统，一台数据采集器可带 15 台流量计；</div>
<div>C．由 RS-485 接口与 HW-Ⅱ数据采集器配套，可组成宽带网络通信系统，由 INTERNET 传输数据，一台数据采集器可带 8 台流量计。</div>
<div>3.6.5 4～20mA 标准电流信号（光电隔离）</div>
<div>与标准体积流量成正比，4mA 对应 0 m3/h， 20 mA 对应最大标准体积流量（该值可在一级菜单中进行设置），制式：两线制或三线制，流量计可根据所插电流模块自动识别，并正确输出。</div>
<div>3.6.6 控制信号输出</div>
<div>A.下限报警信号（LP）：光电隔离，高低电平报警，报警电平可设定，工作电压＋12V~+24V，最大负载电流 50mA；</div>
<div>B.上限报警信号（UP）：光电隔离，高低电平报警，报警电平可设定，工作电压＋12V~+24V，最大负载电流 50mA；</div>
<div>C.关阀报警输出（BC 端，IC 卡控制器用）：逻辑门电路输出，正常输出低电平，幅度≤0.2V；报警输出高电平，幅度≥2.8V,负载电阻≥100kΩ；</div>
<div>D.电池欠压报警输出（BL 端，IC 卡控制器用）：逻辑门电路输出，正常输出低电平，幅 度≤0.2V；报警输出高电平，幅度≥2.8V,负载电阻≥100kΩ；</div>
<div>3.7 现场显示功能</div>
<div>A.积算仪显示面板上实时显示工况（或标况）下的温度、压力、瞬时流量、累计流量；</div>
<div>B.报警功能：流量上下限、温度上下限、压力上下限报警，报警方式：字符闪烁。</div>
<div>3.8 防爆型式与等级</div>
<div>隔爆型：其防爆标志为 ExdIIBT4、ExdIICT4-T6(不含乙炔）；</div>
<div>本安型：其防爆标志为 ExiaIICT4</div>
<div>3.9 防护等级</div>
<div>IP65</div>
<div>3.10 压力损失</div>
<div>流量计实际压力损失计算公式如下：</div>
<div><img decoding="async" style="width: 337px; height: 50px;" src="/uploads/allimg/210315/1-210315203055C1.jpg" alt="" /></div>
<div>式中：</div>
<div>ΔP1&#8211;流量计实际压力损失（KPa）；</div>
<div>ρ&#8211;被测介质密度(kg/m3);</div>
<div>ΔP&#8211;介质为干空气时流量计的压力损失（KPa）。其特性曲线见图 4</div>
<div><img decoding="async" style="width: 550px; height: 483px;" src="/uploads/allimg/210315/1-21031520310N29.jpg" alt="" /></div>
<div>3.11 电器接口</div>
<div>内螺纹 M20*1.5</div>
<div>3.12 选型指南</div>
<div>3.12.1 选型条件</div>
<div>用户订货时应根据管道公称压力、最高工作压力、工作温度、流量范围、环境条件等选择合适的流量计型号和规格。</div>
<div>3.12.2 合理选型</div>
<div>A、用户提供的被测流量为工况流量时，可直接依据表 2 选取相应通径的流量计；</div>
<div>B、用户提供的被测流量为标况流量时，应将标况流量换算为工况流量，选取相应通径的流量计。</div>
<div>换算公式：</div>
<div><img decoding="async" style="width: 435px; height: 392px;" src="/uploads/allimg/210315/1-210315203119128.jpg" alt="" /></div>
<div></div>
<div>四、仪表外形尺寸及安装</div>
<div>4.1 流量计外形尺寸</div>
<div>流量计的外形尺寸见图 5，图中未注尺寸列于表 2 中，流量计采用法兰连接方式。法兰尺寸执行 GB/T9112～9113-2000 标准。</div>
<div><img decoding="async" style="width: 550px; height: 313px;" src="/uploads/allimg/210315/1-210315203130922.jpg" alt="" /></div>
<div><img decoding="async" style="width: 550px; height: 432px;" src="/uploads/allimg/210315/1-210315203142151.jpg" alt="" /></div>
<div>注：以上数据仅供参考，具体以实物为准，如有技术升级，暂不另行通知</div>
<div>4.2 流量计安装</div>
<div>4.2.1 流量计的安装</div>
<div>1.流量计安装时，严禁在其进出口法兰处直接进行电焊，以免烧坏流量计内部零件。</div>
<div>2.对于新安装或检修后的管道务必进行清扫，去除管道中的杂物后方能安装流量计。</div>
<div>3.流量计应安装在便于维修、无强电磁场干扰、无强烈机械振动以及热辐射影响的场所；</div>
<div>4.流量计不宜用在流量频繁中断和有强烈脉动流或压力脉动的场合；</div>
<div>5.流量计室外安装时，上部应有遮盖物，以防雨水浸入和烈日曝晒影响流量计使用寿命；</div>
<div>6.流量计可任意角度安装，流体的流向应与流量计上标识的流向一致；</div>
<div>7.在管道施工中，应考虑安装伸缩管或波纹管，以免对流量计造成严重的拉伸或断裂；</div>
<div>8.流量计应与管道同轴安装，并防止密封片和黄油进入管道内腔；</div>
<div>9.采用外电源时，流量计必须有可靠接地，不得与强电系统共用地线，在管道安装或检修时，不得把电焊系统的地线与流量计搭接。</div>
<div>10.为了不影响流体正常输送和便于维护，要求按图 6 所示安装旁通管道，并保证前≥3DN、 后≥1DN 的直管段；</div>
<div><img decoding="async" style="width: 550px; height: 282px;" src="/uploads/allimg/210315/1-21031520315E02.jpg" alt="" /></div>
<div>4.2.2 直管段要求</div>
<div>根据旋进旋涡流量计的工作原理和流量计对上、下游直管段要求，对各种上游阻力件，建议采用如图 7 所列的前后直管段长度，且保持直管段内壁光滑平直。</div>
<div><img decoding="async" style="width: 550px; height: 495px;" src="/uploads/allimg/210315/1-21031520320c40.jpg" alt="" /></div>
<div>4.2.3 安装注意事项</div>
<div>1.传感器按流向标志可在垂直、水平或任意倾斜位置上安装；</div>
<div>2.当管线较长或距离振动源较近时，应在流量计的上、下游安装支撑，以消除管线振动的影响；</div>
<div>3.传感器的安装地点应有足够的空间，以便于流量计的检查和维修，并应满足流量计的环境要求；</div>
<div>4.应避免外界强磁场的干扰；</div>
<div>5.在室外安装使用时，应有遮盖物，避免烈日曝晒与雨水浸蚀，影响仪表使用寿命；</div>
<div>6.管线试压时，应注意智能型流量计所配置压力传感器的压力测量范围,以免过压损坏压力传感器；</div>
<div>7.应注意安装应力的影响，安装流量计上游和下游管道应同轴，否则会产生剪切应力。安装流量计的位置应考虑密封垫片的厚度，或在下游安装一个弹性伸缩节；</div>
<div>8.安装流量计之前应先清除管道中的焊渣等杂物；</div>
<div>9.投入运行时，应缓慢开启流量计上、下游阀门，以免瞬间气流过急而冲坏起旋器；</div>
<div>10.当流量计需要有信号远传时，应严格按“工作电源”要求接入外电源（8～24）VDC，严禁在信号输出口直接接入 220VAC 或 380VAC 电源；</div>
<div>11.用户不得自行更改防爆系统的接线方式和任意拧动各个输出引线接头；</div>
<div>12.流量计运行时，不允许随意打开后盖改动仪表参数，否则影响流量计的正常工作；</div>
<div>13.定时检查流量计法兰处的泄漏情况。</div>
<div>4.2.4 内置电池的使用及更换</div>
<div>1.电池电量显示</div>
<div>当电池显示仅剩一格时，要求用户在一个月内更换电池；只显示电池外形符号时，则电池电量已耗尽，必须立即更换电池。</div>
<div>2.电池的更换方法</div>
<div>打开智能流量积算仪的后盖，松开电池盖板上的三颗螺钉，拔下电池插座，取出电池，换好新电池后重新安装。</div>
<div>4.2.5 防爆场所安装要求</div>
<div>1.流量计应有可靠的接地，防爆接地不应与强电系统的保护接地共用；</div>
<div>2.现场测试电源时，不允许使用交流电源接地；</div>
<div>3.在任何情况下，用户不得自行更改防爆电路、元器件和防爆型式；</div>
<div>4.必须先切断外接电源再打开转换器盖子。</div>
<div></div>
<div>五、常见故障</div>
<div><img decoding="async" style="width: 550px; height: 494px;" src="/uploads/allimg/210315/1-21031520322RR.jpg" alt="" /></div>
<div></div>
<div>六、包装、运输及贮存</div>
<div>6.1 包装</div>
<div>流量计应装入牢固的木箱内（中、小口径流量计有泡沫保护时可装在纸箱内），不应在箱内自由窜动，搬运时应小心轻放。</div>
<div>6.2 运输</div>
<div>流量计运输贮存条件应符合 GB/T 9329-1999《仪器仪表运输贮存基本环境条件及试验方法》要求</div>
<div>6.3 贮存</div>
<div>流量计的贮存应符合以下条件：</div>
<div>1.防雨防潮</div>
<div>2.不受机械振动或冲击</div>
<div>3.温度范围：5℃～40℃</div>
<div>4.相对湿度：不大于 90%</div>
<div>5.环境不含腐蚀性气体</div>
<p><a href="https://www.zhanfengdesign.com/1397/">旋进旋涡流量计说明书</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>旋进旋涡流量计结构原理</title>
		<link>https://www.zhanfengdesign.com/1396/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Mon, 15 Mar 2021 12:25:21 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计技术文章]]></category>
		<category><![CDATA[旋进旋涡流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>旋进旋涡流量计结构与工作原理 2.1 流 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1396/">旋进旋涡流量计结构原理</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div><strong>旋进旋涡流量计结构与工作原理</strong></div>
<div>2.1 流量计结构</div>
<div><a href="https://www.zhanfengdesign.com/xjxwllj/">旋进旋涡流量计</a>结构紧凑，主要由壳体、旋涡发生体、传感器（温度、压力、流量）、整流器和积算仪构成。</div>
<div><img decoding="async" style="width: 550px; height: 250px;" src="/uploads/allimg/210315/1-210315202J34K.jpg" alt="" /></div>
<div>1.旋涡发生体：用铝合金制成，具有一定角度的螺旋叶片，它固定在壳体收缩段前部，强迫流体产生强烈的旋涡流。</div>
<div>⒉壳体：本身带有法兰，并有一定形状的流体通道，根据不同的工作压力，壳体材料可采用铸铝合金或不锈钢。</div>
<div>⒊智能流量计积算仪：由温度、压力检测模拟通道、流量检测数字通道以及微处理单元、液晶驱动电路和其它辅助电路组成，并配有外输信号接口。</div>
<div>4.温度传感器：以 Pt100/pt1000 铂电阻为温度敏感元件，在一定温度范围内，其电阻值与温度成对应关系。</div>
<div>5.压力传感器：以压阻式扩散硅桥路为敏感元件，其桥臂电阻在外界压力作用下会发生预期变化，因此在一定激励电流作用下，其两个输出端的电位差与外界压力成正比。</div>
<div>6.流量传感器：安装在靠近壳体扩张段的喉部，可检测出旋涡进动的频率信号。</div>
<div>7.整流器：固定在壳体出口段，其作用是消除旋涡流，以减小对下游仪表性能的影响。</div>
<div></div>
<div>2.2 工作原理</div>
<div>流量传感器的流通剖面类似文丘利管的型式（如图 2）。在入口侧安放一组螺旋型导流叶片，当流体进入流量传感器时，导流叶片迫使流体产生剧烈的旋涡流。当流体进入扩散段时，旋涡流受到回流的作用，开始作二次旋转，形成陀螺式的涡流进动现象。该进动频率与流量大小成正比，不受流体物理性质和密度的影响，检测元件测得流体二次旋转进动频率就能在较宽的流量范围内获得良好的线性度。信号经前置放大器放大、滤波、整形转换为与流速成正比的脉冲信号，然后再与温度、压力等检测信号一起被送往微处理器进行积算处理，最后在液晶显示屏上显示出测量结果(瞬时流量、累积流量及温度、压力数据)。积算仪原理框图如图 3 所示。</div>
<div><img decoding="async" style="width: 550px; height: 201px;" src="/uploads/allimg/210315/1-210315202P2133.jpg" alt="" /></div>
<div>2.3 流量积算仪工作原理</div>
<div>流量积算仪由温度和压力检测模拟通道、流量传感器通道以及微处理器单元组成，并配有外输出信号接口，输出各种信号。流量计中的微处理器按照气态方程进行温压补偿，并动进行压缩因子修正，气态方程如下：</div>
<div><img decoding="async" style="width: 474px; height: 56px;" src="/uploads/allimg/210315/1-210315202Q3403.jpg" alt="" /></div>
<div>QN——标况下的体积流量(Nm3/h)；</div>
<div>QV——工况下的体积流量(m3/h)；</div>
<div>Pa——当地大气压力（KPa）；</div>
<div>P ——流量计取压孔测量的表压（KPa）；</div>
<div>PN——标准状态下的大气压力（101.325 KPa）；</div>
<div>TN——标准状态下的绝对温度（293.15K）；</div>
<div>T ——被测流体的绝对温度（K）；</div>
<div>ZN——气体在标况下的压缩系数；</div>
<div>Z ——气体在工况下的压缩系数；</div>
<div>注：当用钟罩或负压标定时取 ZN/Z=1，对天然气(ZN/Z)1/2=FZ为超压缩因子。按中国石油天然气总公司的标准 SY／T6143－1996 中的公式计算。</div>
<div><img decoding="async" style="width: 550px; height: 371px;" src="/uploads/allimg/210315/1-210315202R4622.jpg" alt="" /></div>
<p><a href="https://www.zhanfengdesign.com/1396/">旋进旋涡流量计结构原理</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
