<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>温度仪表 |工业高精度防爆化工智能测温监测设备- 金湖凯铭仪表</title>
	<atom:link href="https://www.zhanfengdesign.com/wdj/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.zhanfengdesign.com/wdj/</link>
	<description>流量&#124;液位&#124;温度&#124;压力</description>
	<lastBuildDate>Wed, 14 Oct 2026 14:38:46 +0000</lastBuildDate>
	<language>zh-Hans</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://www.zhanfengdesign.com/wp-content/uploads/2026/05/elementor/thumbs/微信图片_20250805143107_120_3-rmwn996852eavbnmbpepzofwfik8mes0k2lm3lqvvs.png</url>
	<title>温度仪表 |工业高精度防爆化工智能测温监测设备- 金湖凯铭仪表</title>
	<link>https://www.zhanfengdesign.com/wdj/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>热电阻</title>
		<link>https://www.zhanfengdesign.com/rdz/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Fri, 08 May 2026 14:16:00 +0000</pubDate>
				<guid isPermaLink="false">https://www.zhanfengdesign.com/?post_type=product&#038;p=6998</guid>

					<description><![CDATA[<p>产品概述 工业用热电阻作为测量温度的传感 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/rdz/">热电阻</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="product-post" data-elementor-id="6998" class="elementor elementor-6998" data-elementor-post-type="product">
				<div class="elementor-element elementor-element-e599ef5 e-flex e-con-boxed e-con e-parent" data-id="e599ef5" data-element_type="container" data-e-type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-c0ac202 elementor-widget elementor-widget-heading" data-id="c0ac202" data-element_type="widget" data-e-type="widget" data-widget_type="heading.default">
					<h2 class="elementor-heading-title elementor-size-default">产品概述</h2>				</div>
				<div class="elementor-element elementor-element-0439d87 elementor-widget elementor-widget-text-editor" data-id="0439d87" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
									<p>工业用热电阻作为测量温度的传感器，通常和显示仪表、记录仪表和电子调节器配套使用。它可以直接测量各种生产过程中从-200°C至800°C范围内的液体、蒸汽和气体介质以及固体表面温度。<br />根据国家规定，我公司生产的符合IEC国际标准分度号的Pt100铂电阻和符合专业标准分度号的Cu50铜电阻两大类装配式、统一设计型。<br />产品执行标准：IEC751、IEC1515 JB/T8622-1997、 JB/T8623-1997</p>								</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-031541f e-flex e-con-boxed e-con e-parent" data-id="031541f" data-element_type="container" data-e-type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-0d65283 elementor-widget elementor-widget-heading" data-id="0d65283" data-element_type="widget" data-e-type="widget" data-widget_type="heading.default">
					<h2 class="elementor-heading-title elementor-size-default">技术指标</h2>				</div>
				<div class="elementor-element elementor-element-9568a92 elementor-widget elementor-widget-text-editor" data-id="9568a92" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
									<p>测温范围和准确度</p>								</div>
				<div class="elementor-element elementor-element-8edc75c elementor-widget elementor-widget-tablepress-table" data-id="8edc75c" data-element_type="widget" data-e-type="widget" data-widget_type="tablepress-table.default">
					
<table id="tablepress-82" class="tablepress tablepress-id-82 tbody-has-connected-cells">
<thead>
<tr class="row-1">
	<th class="column-1">类别</th><th class="column-2">测温范围℃</th><th class="column-3">分度号</th><th class="column-4">允许偏差△t℃</th>
</tr>
</thead>
<tbody class="row-striping row-hover">
<tr class="row-2">
	<td rowspan="2" class="column-1">WZP型铂电阻</td><td rowspan="2" class="column-2">-200~420</td><td rowspan="2" class="column-3">Pt100</td><td class="column-4">B级（-200~800℃）<br />
允差±（0.30+0.005|t|）</td>
</tr>
<tr class="row-3">
	<td class="column-4">A级（-200~650℃）<br />
允差±（0.15+0.002|t|）</td>
</tr>
<tr class="row-4">
	<td class="column-1">WZC型铜电阻</td><td class="column-2">-50~100</td><td class="column-3">Cu50</td><td class="column-4">-50~100℃<br />
允差±（0.30+6.0×10⁻³t）</td>
</tr>
</tbody>
</table>
				</div>
				<div class="elementor-element elementor-element-ba36db4 elementor-widget elementor-widget-text-editor" data-id="ba36db4" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
									<p>注:式中“t”为感温元件的实测温度绝对值。<br />感温元件100°C时的电阻值(R100)和它在0°C时的电阻R。比值:(R100/R0。)<br />分度号Pt100：A级 R0=100±0.06Ω，B级 R0=100±0.12Ω，R100/R0=1.3851±0.0012<br />分度号Cu50：R0=50±0.05Ω，R100/R0=1.428+0.002<br />响应时间<br />在温度出现阶跃变化时，输出变化至相当于该阶跃变化的5%，所需要的时间称为热响应时间，用T0.5表示。<br />公称压力<br />一般是指在该工作温度下保护管所能承受的外压(静态)而不破裂。允许公称压力不仅与保护管材料、直径、壁厚有关，还与其结构形式、安装方法、置入深度以及被测介质的流速和种类有关。<br />最小置入深度<br />一般不小于150mm(特殊产品例外)<br />自热影响<br />通过中的测量电流为5mA时，测得的电阻增量换算成温度值应不大于0.30°C。<br />绝缘电阻<br />常温绝缘电阻的试验电压可取直流10~100V任意值，环境温度为15~35°C范围内，相对湿度应不大于80%。常温绝缘电阻值应不小于100MΩ。</p>								</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-60952fa e-flex e-con-boxed e-con e-parent" data-id="60952fa" data-element_type="container" data-e-type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-cb0f55c elementor-widget elementor-widget-heading" data-id="cb0f55c" data-element_type="widget" data-e-type="widget" data-widget_type="heading.default">
					<h2 class="elementor-heading-title elementor-size-default">型号表示</h2>				</div>
				<div class="elementor-element elementor-element-cf13c83 elementor-widget elementor-widget-tablepress-table" data-id="cf13c83" data-element_type="widget" data-e-type="widget" data-widget_type="tablepress-table.default">
					
<table id="tablepress-83" class="tablepress tablepress-id-83 tbody-has-connected-cells">
<thead>
<tr class="row-1">
	<th class="column-1">W</th><th colspan="3" class="column-2">温度仪表</th>
</tr>
</thead>
<tbody class="row-striping row-hover">
<tr class="row-2">
	<td class="column-1">Z</td><td colspan="3" class="column-2">热电阻</td>
</tr>
<tr class="row-3">
	<td rowspan="2" class="column-1">▢</td><td rowspan="2" class="column-2">材料</td><td class="column-3">P</td><td class="column-4">铂电阻</td>
</tr>
<tr class="row-4">
	<td class="column-3">C</td><td class="column-4">铜电阻</td>
</tr>
<tr class="row-5">
	<td rowspan="5" class="column-1">▢</td><td rowspan="5" class="column-2">安装固定形式</td><td class="column-3">1</td><td class="column-4">无固定装置式</td>
</tr>
<tr class="row-6">
	<td class="column-3">2</td><td class="column-4">固定螺纹式</td>
</tr>
<tr class="row-7">
	<td class="column-3">3</td><td class="column-4">活动法兰式</td>
</tr>
<tr class="row-8">
	<td class="column-3">4</td><td class="column-4">固定法兰式</td>
</tr>
<tr class="row-9">
	<td class="column-3">5</td><td class="column-4">固定螺纹锥形保护管式</td>
</tr>
<tr class="row-10">
	<td rowspan="3" class="column-1">▢</td><td rowspan="3" class="column-2">接线盒形式</td><td class="column-3">2</td><td class="column-4">防溅式</td>
</tr>
<tr class="row-11">
	<td class="column-3">3</td><td class="column-4">防水式</td>
</tr>
<tr class="row-12">
	<td class="column-3">非统设</td><td class="column-4">插座式、小接线盒式等</td>
</tr>
<tr class="row-13">
	<td rowspan="3" class="column-1">▢</td><td rowspan="3" class="column-2">设计序号</td><td class="column-3">0</td><td class="column-4">Φ16mm保护管</td>
</tr>
<tr class="row-14">
	<td class="column-3">1</td><td class="column-4">Φ12mm保护管</td>
</tr>
<tr class="row-15">
	<td class="column-3">非统设</td><td class="column-4">各种规格保护管</td>
</tr>
</tbody>
</table>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-2f6cda6 e-flex e-con-boxed e-con e-parent" data-id="2f6cda6" data-element_type="container" data-e-type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-9761e8e elementor-widget elementor-widget-heading" data-id="9761e8e" data-element_type="widget" data-e-type="widget" data-widget_type="heading.default">
					<h2 class="elementor-heading-title elementor-size-default">接线盒结构</h2>				</div>
		<div class="elementor-element elementor-element-ce06d52 e-con-full e-flex e-con e-child" data-id="ce06d52" data-element_type="container" data-e-type="container">
		<div class="elementor-element elementor-element-437ba6c e-con-full e-flex e-con e-child" data-id="437ba6c" data-element_type="container" data-e-type="container">
				<div class="elementor-element elementor-element-e86b590 elementor-widget elementor-widget-image" data-id="e86b590" data-element_type="widget" data-e-type="widget" data-widget_type="image.default">
															<img fetchpriority="high" decoding="async" width="500" height="296" src="https://www.zhanfengdesign.com/wp-content/uploads/2026/05/rdzjxh-e1779153017235.webp" class="attachment-large size-large wp-image-7002" alt="接线盒外形尺寸" />															</div>
				</div>
		<div class="elementor-element elementor-element-71b6d6c e-con-full e-flex e-con e-child" data-id="71b6d6c" data-element_type="container" data-e-type="container">
				<div class="elementor-element elementor-element-40a18cc elementor-widget elementor-widget-image" data-id="40a18cc" data-element_type="widget" data-e-type="widget" data-widget_type="image.default">
															<img decoding="async" width="500" height="349" src="https://www.zhanfengdesign.com/wp-content/uploads/2026/05/rdzgwyj-e1779153029293.webp" class="attachment-large size-large wp-image-7003" alt="感温元件外形尺寸" />															</div>
				</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-eeece17 e-flex e-con-boxed e-con e-parent" data-id="eeece17" data-element_type="container" data-e-type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-d1e6d0e elementor-widget elementor-widget-heading" data-id="d1e6d0e" data-element_type="widget" data-e-type="widget" data-widget_type="heading.default">
					<h2 class="elementor-heading-title elementor-size-default">普通型</h2>				</div>
				<div class="elementor-element elementor-element-00f46ab elementor-widget elementor-widget-text-editor" data-id="00f46ab" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
									<p>固定螺纹式</p>								</div>
				<div class="elementor-element elementor-element-0efe038 elementor-widget elementor-widget-tablepress-table" data-id="0efe038" data-element_type="widget" data-e-type="widget" data-widget_type="tablepress-table.default">
					
<table id="tablepress-84" class="tablepress tablepress-id-84 tbody-has-connected-cells">
<thead>
<tr class="row-1">
	<th class="column-1">类别</th><th class="column-2">产品型号</th><th class="column-3">分度号</th><th class="column-4">测温范围℃</th><th class="column-5">保护管材质</th><th colspan="2" class="column-6">规格</th><th class="column-8">热响应时间<br />
t₀.₅S</th><td class="column-9"></td>
</tr>
</thead>
<tbody class="row-striping row-hover">
<tr class="row-2">
	<td class="column-1"></td><td class="column-2"></td><td class="column-3"></td><td class="column-4"></td><td class="column-5"></td><td class="column-6">总长L（mm）</td><td class="column-7">置深l（mm）</td><td class="column-8"></td><td class="column-9"></td>
</tr>
<tr class="row-3">
	<td rowspan="2" class="column-1">铜电阻<br />
（双股引出线）</td><td rowspan="2" class="column-2">WZC-200</td><td rowspan="2" class="column-3">Cu50（G）*</td><td rowspan="2" class="column-4">-50~100</td><td class="column-5">黄铜H62</td><td rowspan="2" class="column-6">500<br />
550<br />
600<br />
700<br />
900</td><td rowspan="2" class="column-7">100<br />
150<br />
200<br />
300<br />
400</td><td rowspan="2" class="column-8">＜240</td><td rowspan="5" class="column-9"><img decoding="async" src="https://www.jmsensor.com/wp-content/uploads/2026/04/rdz11-282x300.webp" alt="固定螺纹式热电阻" width="282" height="300" class="alignnone size-medium wp-image-10994" /></td>
</tr>
<tr class="row-4">
	<td class="column-5">不锈钢<br />
1CrI8Ni9Ti</td>
</tr>
<tr class="row-5">
	<td class="column-1">单支<br />
铂电阻</td><td class="column-2">WZP-260</td><td rowspan="2" class="column-3">Pt100（BA1，BA2）</td><td rowspan="2" class="column-4">0~100</td><td rowspan="2" class="column-5">不锈钢<br />
1CrI8Ni9Ti</td><td rowspan="2" class="column-6"></td><td rowspan="2" class="column-7">75<br />
100<br />
150<br />
170<br />
180<br />
200<br />
220<br />
270<br />
300<br />
400<br />
410<br />
420</td><td class="column-8">＜30</td>
</tr>
<tr class="row-6">
	<td class="column-1">双支<br />
铂电阻</td><td class="column-2">WZP²-260</td><td class="column-8">＜45</td>
</tr>
<tr class="row-7">
	<td class="column-1">表面<br />
铂电阻</td><td class="column-2">WZPM-267</td><td class="column-3">Pt100（BA1，BA2）</td><td class="column-4">-50~100</td><td class="column-5">不锈钢<br />
1CrI8Ni9Ti</td><td class="column-6">100<br />
150<br />
200<br />
250<br />
300<br />
350</td><td class="column-7"></td><td class="column-8">＜30</td>
</tr>
<tr class="row-8">
	<td colspan="9" class="column-1">注：<br />
1）打"*"分度号作特殊规格订货。<br />
2）WZC-200双股引出电缆作导线。<br />
3）WZPM-267采用引进元件WZPM-018，精度等级为：B级。</td>
</tr>
</tbody>
</table>
				</div>
				<div class="elementor-element elementor-element-d961b00 elementor-widget elementor-widget-text-editor" data-id="d961b00" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
									<p>固定螺纹式</p>								</div>
				<div class="elementor-element elementor-element-dbaa2df elementor-widget elementor-widget-tablepress-table" data-id="dbaa2df" data-element_type="widget" data-e-type="widget" data-widget_type="tablepress-table.default">
					
<table id="tablepress-85" class="tablepress tablepress-id-85 tbody-has-connected-cells">
<thead>
<tr class="row-1">
	<th class="column-1">类别</th><th class="column-2">产品型号</th><th class="column-3">分度号</th><th class="column-4">测温范围℃</th><th class="column-5">保护管材料</th><th colspan="2" class="column-6">规格</th><th class="column-8">热响应时间 t₀.₅S</th><td class="column-9"></td>
</tr>
</thead>
<tbody class="row-striping row-hover">
<tr class="row-2">
	<td class="column-1"></td><td class="column-2"></td><td class="column-3"></td><td class="column-4"></td><td class="column-5"></td><td class="column-6">总长L（mm）</td><td class="column-7">置深l（mm）</td><td class="column-8"></td><td class="column-9"></td>
</tr>
<tr class="row-3">
	<td class="column-1">单支铂电阻</td><td class="column-2">WZP-269</td><td rowspan="2" class="column-3">Pt100（BA1，BA2）*</td><td rowspan="2" class="column-4">-200~300</td><td rowspan="2" class="column-5">不锈钢<br />
1Cr18Ni9Ti</td><td rowspan="3" class="column-6">160<br />
185<br />
235<br />
285<br />
335</td><td rowspan="3" class="column-7">75<br />
100<br />
150<br />
200<br />
250</td><td class="column-8">＜30</td><td rowspan="6" class="column-9"><img loading="lazy" decoding="async" src="https://www.jmsensor.com/wp-content/uploads/2026/04/rdz22-159x300.webp" alt="固定螺纹式热电阻" width="159" height="300" class="alignnone size-medium wp-image-10997" /></td>
</tr>
<tr class="row-4">
	<td class="column-1">双支铂电阻</td><td class="column-2">WZP²-269</td><td class="column-8">＜45</td>
</tr>
<tr class="row-5">
	<td class="column-1">铜电阻</td><td class="column-2">WZC-269</td><td class="column-3">Cu50（G）*</td><td class="column-4">-50~100</td><td class="column-5">不锈钢<br />
1Cr18Ni9Ti</td><td class="column-8">＜120</td>
</tr>
<tr class="row-6">
	<td class="column-1">铂电阻</td><td class="column-2">WZP-270</td><td class="column-3">Pt100（BA1）*</td><td class="column-4">-200~420</td><td rowspan="2" class="column-5">不锈钢<br />
1Cr18Ni9Ti</td><td rowspan="2" class="column-6">95<br />
105<br />
130<br />
155<br />
205</td><td rowspan="2" class="column-7">40<br />
50<br />
75<br />
100<br />
150</td><td class="column-8">＜15</td>
</tr>
<tr class="row-7">
	<td class="column-1">铜电阻</td><td class="column-2">WZC-270</td><td class="column-3">Cu50（G）*</td><td class="column-4">-50~150</td><td class="column-8">＜45</td>
</tr>
<tr class="row-8">
	<td class="column-1">铂电阻</td><td class="column-2">WZP-280</td><td class="column-3">Pt100（BA1，BA2）*</td><td class="column-4">-200~300</td><td class="column-5">不锈钢<br />
1Cr18Ni9Ti</td><td class="column-6">175<br />
200<br />
250<br />
300<br />
350</td><td class="column-7">75<br />
100<br />
150<br />
200<br />
250</td><td class="column-8">＜30</td>
</tr>
<tr class="row-9">
	<td colspan="9" class="column-1">注：打”*“分度号作特殊规格订货。</td>
</tr>
<tr class="row-10">
	<td colspan="9" class="column-1">260、269型直径型号对照表</td>
</tr>
<tr class="row-11">
	<td class="column-1">产品型号</td><td colspan="8" class="column-2">直径Dmm</td>
</tr>
<tr class="row-12">
	<td class="column-1">WZP-269</td><td class="column-2">Φ12</td><td colspan="7" rowspan="5" class="column-3"><img loading="lazy" decoding="async" src="https://www.jmsensor.com/wp-content/uploads/2026/04/rdz33-300x288.webp" alt="固定螺纹式热电阻" width="300" height="288" class="alignnone size-medium wp-image-10998" /></td>
</tr>
<tr class="row-13">
	<td class="column-1">WZP²-269</td><td class="column-2">Φ12</td>
</tr>
<tr class="row-14">
	<td class="column-1">WZC-269</td><td class="column-2">Φ12</td>
</tr>
<tr class="row-15">
	<td class="column-1">WZP-260</td><td class="column-2">Φ10</td>
</tr>
<tr class="row-16">
	<td class="column-1">WZP²-260</td><td class="column-2">Φ10</td>
</tr>
</tbody>
</table>
				</div>
					</div>
				</div>
				</div>
		<p><a href="https://www.zhanfengdesign.com/rdz/">热电阻</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>双金属温度计</title>
		<link>https://www.zhanfengdesign.com/sjswdj/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Fri, 08 May 2026 02:25:38 +0000</pubDate>
				<guid isPermaLink="false">https://www.zhanfengdesign.com/?post_type=product&#038;p=6985</guid>

					<description><![CDATA[<p>产品概要 双金属温度计是一种测量中低温度 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/sjswdj/">双金属温度计</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="product-post" data-elementor-id="6985" class="elementor elementor-6985" data-elementor-post-type="product">
				<div class="elementor-element elementor-element-59e8261 e-flex e-con-boxed e-con e-parent" data-id="59e8261" data-element_type="container" data-e-type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-011ca39 elementor-widget elementor-widget-heading" data-id="011ca39" data-element_type="widget" data-e-type="widget" data-widget_type="heading.default">
					<h2 class="elementor-heading-title elementor-size-default">产品概要</h2>				</div>
				<div class="elementor-element elementor-element-cb1457a elementor-widget elementor-widget-text-editor" data-id="cb1457a" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
									<p>双金属温度计是一种测量中低温度的现场检测仪表。可以直接测量各种生产过程中的-80°C~+500°C范围内液体、蒸汽和气体介质温度。现场显示温度，直观方便。安全可靠，使用寿命长。多种结构形式，可满足不同要求。双金属温度计是基于绕制成环性弯曲状的双金属片组成。一端受热膨胀时，带动指针旋转，工作仪表便显示出热电势所应的温度值。</p>								</div>
		<div class="elementor-element elementor-element-f1c5e32 e-con-full e-flex e-con e-child" data-id="f1c5e32" data-element_type="container" data-e-type="container">
		<div class="elementor-element elementor-element-ea5b8af e-con-full e-flex e-con e-child" data-id="ea5b8af" data-element_type="container" data-e-type="container">
				<div class="elementor-element elementor-element-8160691 elementor-widget elementor-widget-image" data-id="8160691" data-element_type="widget" data-e-type="widget" data-widget_type="image.default">
															<img loading="lazy" decoding="async" width="500" height="500" src="https://www.zhanfengdesign.com/wp-content/uploads/2026/05/jxwdbsq-1-e1779153281846.webp" class="attachment-large size-large wp-image-6992" alt="径向型" />															</div>
				<div class="elementor-element elementor-element-138ae10 elementor-widget elementor-widget-heading" data-id="138ae10" data-element_type="widget" data-e-type="widget" data-widget_type="heading.default">
					<h3 class="elementor-heading-title elementor-size-default">径向型双金属温度计</h3>				</div>
				</div>
		<div class="elementor-element elementor-element-066f9cd e-con-full e-flex e-con e-child" data-id="066f9cd" data-element_type="container" data-e-type="container">
				<div class="elementor-element elementor-element-48976f4 elementor-widget elementor-widget-image" data-id="48976f4" data-element_type="widget" data-e-type="widget" data-widget_type="image.default">
															<img loading="lazy" decoding="async" width="500" height="500" src="https://www.zhanfengdesign.com/wp-content/uploads/2026/05/zxswdj2-e1779153170111.webp" class="attachment-large size-large wp-image-6989" alt="轴向型" />															</div>
				<div class="elementor-element elementor-element-50bcf5c elementor-widget elementor-widget-heading" data-id="50bcf5c" data-element_type="widget" data-e-type="widget" data-widget_type="heading.default">
					<h3 class="elementor-heading-title elementor-size-default">轴向型双金属温度计</h3>				</div>
				</div>
		<div class="elementor-element elementor-element-355670a e-con-full e-flex e-con e-child" data-id="355670a" data-element_type="container" data-e-type="container">
				<div class="elementor-element elementor-element-0cdfee3 elementor-widget elementor-widget-image" data-id="0cdfee3" data-element_type="widget" data-e-type="widget" data-widget_type="image.default">
															<img loading="lazy" decoding="async" width="500" height="500" src="https://www.zhanfengdesign.com/wp-content/uploads/2026/05/sjswdj2-1-e1779153300718.webp" class="attachment-large size-large wp-image-6993" alt="万向型" />															</div>
				<div class="elementor-element elementor-element-f9ad77c elementor-widget elementor-widget-heading" data-id="f9ad77c" data-element_type="widget" data-e-type="widget" data-widget_type="heading.default">
					<h3 class="elementor-heading-title elementor-size-default">万向型双金属温度计</h3>				</div>
				</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-a0657b7 e-flex e-con-boxed e-con e-parent" data-id="a0657b7" data-element_type="container" data-e-type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-efcd2c6 elementor-widget elementor-widget-heading" data-id="efcd2c6" data-element_type="widget" data-e-type="widget" data-widget_type="heading.default">
					<h2 class="elementor-heading-title elementor-size-default">技术参数</h2>				</div>
				<div class="elementor-element elementor-element-13f2214 elementor-widget elementor-widget-text-editor" data-id="13f2214" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
									<p>产品执行标准JB/T8803-1998 GB38369-83<br />标度盘公称直径：60,100,150<br />精度等级：(1.0)，1.5<br />热响应时间：≤40s<br />防护等级：IP55<br />角度调整误差<br />角度调整误差应不超过其量程的1.0%<br />回差<br />温度计回差应不大于基本误差限的绝对值<br />重复性<br />温度计重复性极限范围值应不大于基本误差限绝对值的1/2<br />测温范围</p>								</div>
				<div class="elementor-element elementor-element-5489acb elementor-widget elementor-widget-tablepress-table" data-id="5489acb" data-element_type="widget" data-e-type="widget" data-widget_type="tablepress-table.default">
					
<table id="tablepress-78" class="tablepress tablepress-id-78">
<thead>
<tr class="row-1">
	<th class="column-1">测温范围℃</th><th colspan="2" class="column-2">适应范围</th>
</tr>
</thead>
<tbody class="row-striping row-hover">
<tr class="row-2">
	<td class="column-1">-80~+40℃</td><td class="column-2">工业，商业</td><td class="column-3">实验室，小型</td>
</tr>
<tr class="row-3">
	<td class="column-1">-40~+80℃</td><td class="column-2">✔</td><td class="column-3">✔</td>
</tr>
<tr class="row-4">
	<td class="column-1">0~50℃</td><td class="column-2">✔</td><td class="column-3">✔</td>
</tr>
<tr class="row-5">
	<td class="column-1">0~100℃</td><td class="column-2">✔</td><td class="column-3">✔</td>
</tr>
<tr class="row-6">
	<td class="column-1">0~150℃</td><td class="column-2">✔</td><td class="column-3">✔</td>
</tr>
<tr class="row-7">
	<td class="column-1">0~200℃</td><td class="column-2">✔</td><td class="column-3">✔</td>
</tr>
<tr class="row-8">
	<td class="column-1">0~300℃</td><td class="column-2">✔</td><td class="column-3">✔</td>
</tr>
<tr class="row-9">
	<td class="column-1">0~400℃</td><td class="column-2">✔</td><td class="column-3">-</td>
</tr>
<tr class="row-10">
	<td class="column-1">0~500℃</td><td class="column-2">✔</td><td class="column-3">-</td>
</tr>
</tbody>
</table>
				</div>
				<div class="elementor-element elementor-element-d51f809 elementor-widget elementor-widget-tablepress-table" data-id="d51f809" data-element_type="widget" data-e-type="widget" data-widget_type="tablepress-table.default">
					
<table id="tablepress-79" class="tablepress tablepress-id-79 tbody-has-connected-cells">
<thead>
<tr class="row-1">
	<th colspan="3" class="column-1">正常工作大气条件</th>
</tr>
</thead>
<tbody class="row-striping row-hover">
<tr class="row-2">
	<td class="column-1">工作场所</td><td class="column-2">温度℃</td><td class="column-3">相对湿度%RH</td>
</tr>
<tr class="row-3">
	<td class="column-1">掩蔽场所</td><td class="column-2">-25~+25℃</td><td class="column-3">5~100</td>
</tr>
<tr class="row-4">
	<td class="column-1">户外场所</td><td class="column-2">-40~+85℃</td><td class="column-3">5~100</td>
</tr>
<tr class="row-5">
	<td colspan="3" class="column-1">测量端形式</td>
</tr>
<tr class="row-6">
	<td colspan="3" class="column-1"><img loading="lazy" decoding="async" src="https://www.jmsensor.com/wp-content/uploads/2026/04/sjscld1-300x75.webp" alt="测量端形式" width="300" height="75" class="alignnone size-medium wp-image-10970" /></td>
</tr>
</tbody>
</table>
				</div>
				<div class="elementor-element elementor-element-4954f01 elementor-widget elementor-widget-tablepress-table" data-id="4954f01" data-element_type="widget" data-e-type="widget" data-widget_type="tablepress-table.default">
					
<table id="tablepress-80" class="tablepress tablepress-id-80 tbody-has-connected-cells">
<thead>
<tr class="row-1">
	<th colspan="7" class="column-1">外形尺寸</th>
</tr>
</thead>
<tbody class="row-striping row-hover">
<tr class="row-2">
	<td class="column-1">形式</td><td class="column-2">A</td><td class="column-3">B</td><td class="column-4">C</td><td class="column-5">E</td><td class="column-6">L</td><td class="column-7">D</td>
</tr>
<tr class="row-3">
	<td rowspan="3" class="column-1">轴向型</td><td class="column-2">65</td><td class="column-3">23</td><td class="column-4">73</td><td class="column-5">-</td><td rowspan="10" class="column-6">75<br />
100<br />
150<br />
200<br />
300<br />
400<br />
500<br />
750<br />
1000</td><td rowspan="10" class="column-7">Φ6<br />
Φ8<br />
Φ10</td>
</tr>
<tr class="row-4">
	<td class="column-2">105</td><td class="column-3">23</td><td class="column-4">73</td><td class="column-5">-</td>
</tr>
<tr class="row-5">
	<td class="column-2">155</td><td class="column-3">23</td><td class="column-4">73</td><td class="column-5">-</td>
</tr>
<tr class="row-6">
	<td rowspan="3" class="column-1">径向型</td><td class="column-2">65</td><td class="column-3">50</td><td class="column-4">110</td><td class="column-5">34</td>
</tr>
<tr class="row-7">
	<td class="column-2">105</td><td class="column-3">50</td><td class="column-4">110</td><td class="column-5">34</td>
</tr>
<tr class="row-8">
	<td class="column-2">155</td><td class="column-3">50</td><td class="column-4">110</td><td class="column-5">34</td>
</tr>
<tr class="row-9">
	<td rowspan="2" class="column-1">135°向型</td><td class="column-2">105</td><td class="column-3">23</td><td class="column-4">85</td><td class="column-5">-</td>
</tr>
<tr class="row-10">
	<td class="column-2">155</td><td class="column-3">23</td><td class="column-4">85</td><td class="column-5">-</td>
</tr>
<tr class="row-11">
	<td rowspan="2" class="column-1">万向型</td><td class="column-2">105</td><td class="column-3">23</td><td class="column-4">178</td><td class="column-5">120</td>
</tr>
<tr class="row-12">
	<td class="column-2">155</td><td class="column-3">23</td><td class="column-4">178</td><td class="column-5">120</td>
</tr>
</tbody>
</table>
				</div>
				<div class="elementor-element elementor-element-c492b21 elementor-widget elementor-widget-tablepress-table" data-id="c492b21" data-element_type="widget" data-e-type="widget" data-widget_type="tablepress-table.default">
					
<table id="tablepress-81" class="tablepress tablepress-id-81 tbody-has-connected-cells">
<thead>
<tr class="row-1">
	<th colspan="7" class="column-1">安装固定形式</th>
</tr>
</thead>
<tbody class="row-striping row-hover">
<tr class="row-2">
	<td colspan="7" class="column-1">可动外螺纹管接头</td>
</tr>
<tr class="row-3">
	<td class="column-1">M</td><td class="column-2">H</td><td class="column-3">SW</td><td rowspan="7" class="column-4">Φ6<br />
Φ8<br />
Φ10</td><td colspan="3" rowspan="8" class="column-5"><img loading="lazy" decoding="async" src="https://www.jmsensor.com/wp-content/uploads/2026/04/wss1-300x141.webp" alt="可动外螺纹管接头" width="300" height="141" class="alignnone size-medium wp-image-10975" /></td>
</tr>
<tr class="row-4">
	<td class="column-1">M16×1.5</td><td class="column-2">12</td><td class="column-3">18</td>
</tr>
<tr class="row-5">
	<td class="column-1">M20×1.5</td><td class="column-2">16</td><td class="column-3">22</td>
</tr>
<tr class="row-6">
	<td class="column-1">M27×2</td><td class="column-2">20</td><td class="column-3">30</td>
</tr>
<tr class="row-7">
	<td class="column-1">NPT1/4</td><td class="column-2">15</td><td class="column-3">18</td>
</tr>
<tr class="row-8">
	<td class="column-1">NPT1/2</td><td class="column-2">19</td><td class="column-3">22</td>
</tr>
<tr class="row-9">
	<td class="column-1">NPT3/4</td><td class="column-2">25</td><td class="column-3">30</td>
</tr>
<tr class="row-10">
	<td colspan="4" class="column-1">可动内螺纹管接头</td>
</tr>
<tr class="row-11">
	<td class="column-1">M</td><td class="column-2">H</td><td class="column-3">SW</td><td rowspan="7" class="column-4">Φ6<br />
Φ8<br />
Φ10</td><td colspan="3" rowspan="8" class="column-5"><img loading="lazy" decoding="async" src="https://www.jmsensor.com/wp-content/uploads/2026/04/wss2-300x173.webp" alt="可动内螺纹管接头" width="300" height="173" class="alignnone size-medium wp-image-10976" /></td>
</tr>
<tr class="row-12">
	<td class="column-1">M16×1.5</td><td class="column-2">12</td><td class="column-3">18</td>
</tr>
<tr class="row-13">
	<td class="column-1">M20×1.5</td><td class="column-2">16</td><td class="column-3">22</td>
</tr>
<tr class="row-14">
	<td class="column-1">M27×2</td><td class="column-2">20</td><td class="column-3">30</td>
</tr>
<tr class="row-15">
	<td class="column-1">NPT1/4</td><td class="column-2">15</td><td class="column-3">18</td>
</tr>
<tr class="row-16">
	<td class="column-1">NPT1/2</td><td class="column-2">19</td><td class="column-3">22</td>
</tr>
<tr class="row-17">
	<td class="column-1">NPT3/4</td><td class="column-2">25</td><td class="column-3">30</td>
</tr>
<tr class="row-18">
	<td colspan="4" class="column-1">固定螺纹接头</td>
</tr>
<tr class="row-19">
	<td class="column-1">M</td><td class="column-2">H</td><td class="column-3">SW</td><td rowspan="7" class="column-4">Φ6<br />
Φ8<br />
Φ10</td><td colspan="3" rowspan="8" class="column-5"><img loading="lazy" decoding="async" src="https://www.jmsensor.com/wp-content/uploads/2026/04/wss3-300x145.webp" alt="固定螺纹接头" width="300" height="145" class="alignnone size-medium wp-image-10977" /></td>
</tr>
<tr class="row-20">
	<td class="column-1">M16×1.5</td><td class="column-2">12</td><td class="column-3">18</td>
</tr>
<tr class="row-21">
	<td class="column-1">M20×1.5</td><td class="column-2">16</td><td class="column-3">22</td>
</tr>
<tr class="row-22">
	<td class="column-1">M27×2</td><td class="column-2">20</td><td class="column-3">30</td>
</tr>
<tr class="row-23">
	<td class="column-1">NPT1/4</td><td class="column-2">15</td><td class="column-3">18</td>
</tr>
<tr class="row-24">
	<td class="column-1">NPT1/2</td><td class="column-2">19</td><td class="column-3">22</td>
</tr>
<tr class="row-25">
	<td class="column-1">NPT3/4</td><td class="column-2">25</td><td class="column-3">30</td>
</tr>
<tr class="row-26">
	<td colspan="4" class="column-1">卡套螺纹接头</td>
</tr>
<tr class="row-27">
	<td class="column-1">M</td><td class="column-2">H</td><td class="column-3">SW</td><td class="column-4">d</td><td colspan="3" rowspan="5" class="column-5"><img loading="lazy" decoding="async" src="https://www.jmsensor.com/wp-content/uploads/2026/04/wss4-300x191.webp" alt="卡套螺纹接头" width="300" height="191" class="alignnone size-medium wp-image-10978" /></td>
</tr>
<tr class="row-28">
	<td class="column-1">M12×1.5</td><td class="column-2">15</td><td class="column-3">19</td><td class="column-4">Φ6</td>
</tr>
<tr class="row-29">
	<td class="column-1">M16×1.5</td><td class="column-2">15</td><td class="column-3">22</td><td rowspan="2" class="column-4">Φ8<br />
Φ10</td>
</tr>
<tr class="row-30">
	<td class="column-1">M20×1.5</td><td class="column-2">16</td><td class="column-3">24</td>
</tr>
<tr class="row-31">
	<td colspan="4" class="column-1">卡套法兰接头</td>
</tr>
<tr class="row-32">
	<td class="column-1">D</td><td class="column-2">D₀</td><td class="column-3">D₁</td><td class="column-4">SW</td><td class="column-5">d₀</td><td class="column-6">d</td><td rowspan="2" class="column-7"><img loading="lazy" decoding="async" src="https://www.jmsensor.com/wp-content/uploads/2026/04/wss5-300x208.webp" alt="卡套法兰接头" width="300" height="208" class="alignnone size-medium wp-image-10979" /></td>
</tr>
<tr class="row-33">
	<td class="column-1">Φ60</td><td class="column-2">Φ42</td><td class="column-3">Φ24</td><td class="column-4">Φ22</td><td class="column-5">Φ9</td><td class="column-6">Φ8<br />
Φ10</td>
</tr>
<tr class="row-34">
	<td colspan="7" class="column-1">固定法兰</td>
</tr>
<tr class="row-35">
	<td class="column-1">D</td><td class="column-2">D₀</td><td class="column-3">D₁</td><td class="column-4">H</td><td class="column-5">d₀</td><td class="column-6">d</td><td rowspan="2" class="column-7"><img loading="lazy" decoding="async" src="https://www.jmsensor.com/wp-content/uploads/2026/04/wss6-300x195.webp" alt="固定法兰" width="300" height="195" class="alignnone size-medium wp-image-10980" /></td>
</tr>
<tr class="row-36">
	<td class="column-1">Φ105</td><td class="column-2">Φ75</td><td class="column-3">Φ55</td><td class="column-4">Φ16</td><td class="column-5">Φ14</td><td class="column-6">Φ8<br />
Φ10</td>
</tr>
<tr class="row-37">
	<td colspan="7" class="column-1">注：可提供ANSI，JB，HG等标准法兰</td>
</tr>
</tbody>
</table>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-36d21e4 e-flex e-con-boxed e-con e-parent" data-id="36d21e4" data-element_type="container" data-e-type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-97799d7 elementor-widget elementor-widget-heading" data-id="97799d7" data-element_type="widget" data-e-type="widget" data-widget_type="heading.default">
					<h2 class="elementor-heading-title elementor-size-default">选型</h2>				</div>
				<div class="elementor-element elementor-element-4e5a2ad elementor-widget elementor-widget-tablepress-table" data-id="4e5a2ad" data-element_type="widget" data-e-type="widget" data-widget_type="tablepress-table.default">
					
<table id="tablepress-77" class="tablepress tablepress-id-77 tbody-has-connected-cells">
<thead>
<tr class="row-1">
	<th class="column-1">W</th><th colspan="3" class="column-2">温度仪表</th>
</tr>
</thead>
<tbody class="row-striping row-hover">
<tr class="row-2">
	<td class="column-1">S</td><td colspan="3" class="column-2">金属膨胀式</td>
</tr>
<tr class="row-3">
	<td class="column-1">S</td><td colspan="3" class="column-2">双金属片</td>
</tr>
<tr class="row-4">
	<td class="column-1">▢</td><td colspan="3" class="column-2">X带电接点</td>
</tr>
<tr class="row-5">
	<td rowspan="3" class="column-1">▢</td><td rowspan="3" class="column-2">表壳公称直径</td><td class="column-3">3）</td><td class="column-4">Φ60</td>
</tr>
<tr class="row-6">
	<td class="column-3">4）</td><td class="column-4">Φ100</td>
</tr>
<tr class="row-7">
	<td class="column-3">5）</td><td class="column-4">Φ150</td>
</tr>
<tr class="row-8">
	<td rowspan="7" class="column-1">▢</td><td rowspan="7" class="column-2">结构形式</td><td class="column-3">0）</td><td class="column-4">轴向（直型）</td>
</tr>
<tr class="row-9">
	<td class="column-3">1）</td><td class="column-4">径向（角型）</td>
</tr>
<tr class="row-10">
	<td class="column-3">2）</td><td class="column-4">135°向（钝角型）</td>
</tr>
<tr class="row-11">
	<td class="column-3">5）</td><td class="column-4">热套式角型（抽芯式）</td>
</tr>
<tr class="row-12">
	<td class="column-3">6）</td><td class="column-4">热套式直型（抽芯式）</td>
</tr>
<tr class="row-13">
	<td class="column-3">7）</td><td class="column-4">热套式万向型（抽芯式）</td>
</tr>
<tr class="row-14">
	<td class="column-3">8）</td><td class="column-4">万向（可调角型）</td>
</tr>
<tr class="row-15">
	<td rowspan="7" class="column-1">▢</td><td rowspan="7" class="column-2">安装方式</td><td class="column-3">0）</td><td class="column-4">无固定装置</td>
</tr>
<tr class="row-16">
	<td class="column-3">1）</td><td class="column-4">可动外螺纹</td>
</tr>
<tr class="row-17">
	<td class="column-3">2）</td><td class="column-4">可动内螺纹</td>
</tr>
<tr class="row-18">
	<td class="column-3">3）</td><td class="column-4">固定螺纹</td>
</tr>
<tr class="row-19">
	<td class="column-3">4）</td><td class="column-4">固定法兰</td>
</tr>
<tr class="row-20">
	<td class="column-3">5）</td><td class="column-4">卡套螺纹</td>
</tr>
<tr class="row-21">
	<td class="column-3">6）</td><td class="column-4">卡套法兰</td>
</tr>
<tr class="row-22">
	<td rowspan="3" class="column-1">▢</td><td rowspan="3" class="column-2">防护形式</td><td class="column-3">无（未标注）</td><td class="column-4">普通型</td>
</tr>
<tr class="row-23">
	<td class="column-3">N</td><td class="column-4">耐震型（充油式）</td>
</tr>
<tr class="row-24">
	<td class="column-3">F</td><td class="column-4">防腐性</td>
</tr>
</tbody>
</table>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-eefe9a4 e-flex e-con-boxed e-con e-parent" data-id="eefe9a4" data-element_type="container" data-e-type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-3b9ba5d elementor-widget elementor-widget-heading" data-id="3b9ba5d" data-element_type="widget" data-e-type="widget" data-widget_type="heading.default">
					<h2 class="elementor-heading-title elementor-size-default">型号规格及测量范围</h2>				</div>
				<div class="elementor-element elementor-element-b350808 elementor-widget elementor-widget-tablepress-table" data-id="b350808" data-element_type="widget" data-e-type="widget" data-widget_type="tablepress-table.default">
					
<table id="tablepress-76" class="tablepress tablepress-id-76 tbody-has-connected-cells">
<thead>
<tr class="row-1">
	<th colspan="3" class="column-1">型号</th><th class="column-4">外壳公称直径D</th><th class="column-5">测温范围℃</th><th class="column-6">分格值℃</th><th class="column-7">插入长度L</th><th class="column-8">保护管直径d</th><th class="column-9">安装螺纹T</th>
</tr>
</thead>
<tbody class="row-striping row-hover">
<tr class="row-2">
	<td rowspan="4" class="column-1">轴向直型</td><td rowspan="2" class="column-2">外螺纹节头</td><td rowspan="2" class="column-3">WSS301<br />
401<br />
501</td><td class="column-4">67</td><td rowspan="3" class="column-5">-10~+40℃</td><td rowspan="3" class="column-6">1</td><td class="column-7">75</td><td class="column-8">6</td><td class="column-9">M16×1.5，G1/2"</td>
</tr>
<tr class="row-3">
	<td class="column-4">107<br />
157</td><td rowspan="2" class="column-7">100</td><td class="column-8">10</td><td class="column-9">M27×2，G3/4"</td>
</tr>
<tr class="row-4">
	<td rowspan="2" class="column-2">内螺纹节头</td><td rowspan="2" class="column-3">WSS302<br />
402<br />
502</td><td class="column-4">67</td><td class="column-8">6</td><td class="column-9">M16×1.5，G1/2"</td>
</tr>
<tr class="row-5">
	<td class="column-4">107<br />
157</td><td rowspan="3" class="column-5">-80~+40℃</td><td rowspan="3" class="column-6">2</td><td rowspan="2" class="column-7">150</td><td class="column-8">10</td><td class="column-9">M27×2，G3/4"</td>
</tr>
<tr class="row-6">
	<td rowspan="4" class="column-1">径向角型</td><td rowspan="2" class="column-2">外螺纹节头</td><td rowspan="2" class="column-3">WSS311<br />
411<br />
511</td><td class="column-4">67</td><td class="column-8">6</td><td class="column-9">M16×1.5，G1/2"</td>
</tr>
<tr class="row-7">
	<td class="column-4">107<br />
157</td><td rowspan="2" class="column-7">200</td><td class="column-8">10</td><td class="column-9">M27×2，G3/4"</td>
</tr>
<tr class="row-8">
	<td rowspan="2" class="column-2">内螺纹节头</td><td rowspan="2" class="column-3">WSS312<br />
412<br />
512</td><td class="column-4">67</td><td rowspan="3" class="column-5">0~+50℃</td><td rowspan="3" class="column-6">1</td><td class="column-8">6</td><td class="column-9">M16×1.5，G1/2"</td>
</tr>
<tr class="row-9">
	<td class="column-4">107<br />
157</td><td rowspan="2" class="column-7">250</td><td rowspan="9" class="column-8">10</td><td rowspan="21" class="column-9">M27×2，G3/4"</td>
</tr>
<tr class="row-10">
	<td rowspan="2" class="column-1">万向型</td><td class="column-2">外螺纹节头</td><td class="column-3">WSS481<br />
581</td><td class="column-4">107<br />
157</td>
</tr>
<tr class="row-11">
	<td class="column-2">内螺纹节头</td><td class="column-3">WSS482<br />
582</td><td class="column-4">107<br />
157</td><td rowspan="3" class="column-5">0~+100℃</td><td rowspan="3" class="column-6">2</td><td rowspan="2" class="column-7">300</td>
</tr>
<tr class="row-12">
	<td rowspan="2" class="column-1">热套式直型</td><td class="column-2">外螺纹节头</td><td class="column-3">WSS451<br />
551</td><td class="column-4">107<br />
157</td>
</tr>
<tr class="row-13">
	<td class="column-2">内螺纹节头</td><td class="column-3">WSS452<br />
552</td><td class="column-4">107<br />
157</td><td rowspan="2" class="column-7">400</td>
</tr>
<tr class="row-14">
	<td rowspan="2" class="column-1">热套式角型</td><td class="column-2">外螺纹节头</td><td class="column-3">WSS461<br />
561</td><td class="column-4">107<br />
157</td><td rowspan="3" class="column-5">0~+150℃</td><td rowspan="3" class="column-6">2</td>
</tr>
<tr class="row-15">
	<td class="column-2">内螺纹节头</td><td class="column-3">WSS462<br />
562</td><td class="column-4">107<br />
157</td><td class="column-7">500</td>
</tr>
<tr class="row-16">
	<td rowspan="2" class="column-1">热套式万向型</td><td class="column-2">外螺纹节头</td><td class="column-3">WSS471<br />
571</td><td class="column-4">107<br />
157</td><td class="column-7">750</td>
</tr>
<tr class="row-17">
	<td class="column-2">内螺纹节头</td><td class="column-3">WSS472<br />
572</td><td class="column-4">107<br />
157</td><td rowspan="3" class="column-5">0~+200℃</td><td rowspan="3" class="column-6">5</td><td class="column-7">1000</td>
</tr>
<tr class="row-18">
	<td rowspan="2" class="column-1">电接点直型</td><td class="column-2">外螺纹节头</td><td class="column-3">WSSX401</td><td rowspan="12" class="column-4">107</td><td rowspan="3" class="column-7">1250</td><td rowspan="12" class="column-8">12</td>
</tr>
<tr class="row-19">
	<td class="column-2">内螺纹节头</td><td class="column-3">WSSX402</td>
</tr>
<tr class="row-20">
	<td rowspan="2" class="column-1">电接点角型</td><td class="column-2">外螺纹节头</td><td class="column-3">WSSX411</td><td rowspan="3" class="column-5">0~+300℃</td><td rowspan="3" class="column-6">5</td>
</tr>
<tr class="row-21">
	<td class="column-2">内螺纹节头</td><td class="column-3">WSSX412</td><td rowspan="3" class="column-7">1500</td>
</tr>
<tr class="row-22">
	<td rowspan="2" class="column-1">电接点万向型</td><td class="column-2">外螺纹节头</td><td class="column-3">WSSX481</td>
</tr>
<tr class="row-23">
	<td class="column-2">内螺纹节头</td><td class="column-3">WSSX482</td><td rowspan="3" class="column-5">0~+400℃</td><td rowspan="3" class="column-6">10</td>
</tr>
<tr class="row-24">
	<td rowspan="2" class="column-1">热套式角型电接点</td><td class="column-2">外螺纹节头</td><td class="column-3">WSSX451</td><td rowspan="3" class="column-7">1750</td>
</tr>
<tr class="row-25">
	<td class="column-2">内螺纹节头</td><td class="column-3">WSSX452</td>
</tr>
<tr class="row-26">
	<td rowspan="2" class="column-1">热套式直型电接点</td><td class="column-2">外螺纹节头</td><td class="column-3">WSSX461</td><td rowspan="4" class="column-5">0~+500℃</td><td rowspan="4" class="column-6">10</td>
</tr>
<tr class="row-27">
	<td class="column-2">内螺纹节头</td><td class="column-3">WSSX462</td><td rowspan="3" class="column-7">2000</td>
</tr>
<tr class="row-28">
	<td rowspan="2" class="column-1">热套式万向型电接点</td><td class="column-2">外螺纹节头</td><td class="column-3">WSSX471</td>
</tr>
<tr class="row-29">
	<td class="column-2">内螺纹节头</td><td class="column-3">WSSX472</td>
</tr>
</tbody>
</table>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-a8f27b3 e-flex e-con-boxed e-con e-parent" data-id="a8f27b3" data-element_type="container" data-e-type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-717a87b elementor-widget elementor-widget-heading" data-id="717a87b" data-element_type="widget" data-e-type="widget" data-widget_type="heading.default">
					<h2 class="elementor-heading-title elementor-size-default">使用与维修</h2>				</div>
				<div class="elementor-element elementor-element-bdac767 elementor-widget elementor-widget-text-editor" data-id="bdac767" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
									<p>1、为保证温度计的正确性，尾管浸人被测介质的深度视尾管长度不同应在75以上。<br />2、读数时视线应与标度盘垂直。<br />3、温度计在正常使用后(一般不超过一年)应按工业双金属温度计有关检定规程进行定期检定。<br />4、热套式温度计使用过程中遇到损坏需要更换时，只需逆时针松动螺母1，然后旋出表芯2，保护套3留在设备中，将新的表芯装入，勿使双金属螺管与保护套底部接触，旋紧螺母1即可。<br />5、温度计在运输、保管、安装、使用过程中应避免碰撞尾管，切勿使其弯曲变形。</p>								</div>
					</div>
				</div>
				</div>
		<p><a href="https://www.zhanfengdesign.com/sjswdj/">双金属温度计</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>温度变送器</title>
		<link>https://www.zhanfengdesign.com/wdbsq/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Fri, 08 May 2026 01:42:50 +0000</pubDate>
				<guid isPermaLink="false">https://www.zhanfengdesign.com/?post_type=product&#038;p=6965</guid>

					<description><![CDATA[<p>产品概述 SBWR热电偶温度变送器、SB [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/wdbsq/">温度变送器</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="product-post" data-elementor-id="6965" class="elementor elementor-6965" data-elementor-post-type="product">
				<div class="elementor-element elementor-element-00c939d e-flex e-con-boxed e-con e-parent" data-id="00c939d" data-element_type="container" data-e-type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-6e21f88 elementor-widget elementor-widget-heading" data-id="6e21f88" data-element_type="widget" data-e-type="widget" data-widget_type="heading.default">
					<h2 class="elementor-heading-title elementor-size-default">产品概述</h2>				</div>
				<div class="elementor-element elementor-element-5abd4de elementor-widget elementor-widget-text-editor" data-id="5abd4de" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
									<p>SBWR热电偶温度变送器、SBWZ热电阻温度变送器是DDZ-S系列仪表中的现场安装式温度变送单元。它采用二线传送方式（两根导线作为电源输入，信号输出的公用传输线）。将热电偶、热电阻信号变换成与输入电信号或被测温度成线性的4~20mA的输出信号，变送器可以安装于热电偶、热电阻的接线盒内与之形成一体化结构。它作为新一代测温仪表可广泛应用于冶金、石油化工、电力、轻工、纺织、食品、国防以及科研等工业部门。</p>								</div>
		<div class="elementor-element elementor-element-08ec82e e-con-full e-flex e-con e-child" data-id="08ec82e" data-element_type="container" data-e-type="container">
		<div class="elementor-element elementor-element-2e832d3 e-con-full e-flex e-con e-child" data-id="2e832d3" data-element_type="container" data-e-type="container">
				<div class="elementor-element elementor-element-8f40aaf elementor-widget elementor-widget-image" data-id="8f40aaf" data-element_type="widget" data-e-type="widget" data-widget_type="image.default">
															<img loading="lazy" decoding="async" width="500" height="500" src="https://www.zhanfengdesign.com/wp-content/uploads/2026/05/wdbsq-2-e1779153707342.webp" class="attachment-large size-large wp-image-6971" alt="液晶显示型" />															</div>
				<div class="elementor-element elementor-element-a70ca12 elementor-widget elementor-widget-heading" data-id="a70ca12" data-element_type="widget" data-e-type="widget" data-widget_type="heading.default">
					<h3 class="elementor-heading-title elementor-size-default">液晶显示型</h3>				</div>
				</div>
		<div class="elementor-element elementor-element-0a80c24 e-con-full e-flex e-con e-child" data-id="0a80c24" data-element_type="container" data-e-type="container">
				<div class="elementor-element elementor-element-3e6d863 elementor-widget elementor-widget-image" data-id="3e6d863" data-element_type="widget" data-e-type="widget" data-widget_type="image.default">
															<img loading="lazy" decoding="async" width="500" height="500" src="https://www.zhanfengdesign.com/wp-content/uploads/2026/05/hsmwdbsq-1-e1779153718574.webp" class="attachment-large size-large wp-image-6972" alt="精巧型" />															</div>
				<div class="elementor-element elementor-element-f47b7b8 elementor-widget elementor-widget-heading" data-id="f47b7b8" data-element_type="widget" data-e-type="widget" data-widget_type="heading.default">
					<h3 class="elementor-heading-title elementor-size-default">精巧型</h3>				</div>
				</div>
		<div class="elementor-element elementor-element-048c0b6 e-con-full e-flex e-con e-child" data-id="048c0b6" data-element_type="container" data-e-type="container">
				<div class="elementor-element elementor-element-e74bc42 elementor-widget elementor-widget-image" data-id="e74bc42" data-element_type="widget" data-e-type="widget" data-widget_type="image.default">
															<img loading="lazy" decoding="async" width="500" height="500" src="https://www.zhanfengdesign.com/wp-content/uploads/2026/05/rdz-1-e1779153770908.webp" class="attachment-large size-large wp-image-6973" alt="耦合型" />															</div>
				<div class="elementor-element elementor-element-9cf2a56 elementor-widget elementor-widget-heading" data-id="9cf2a56" data-element_type="widget" data-e-type="widget" data-widget_type="heading.default">
					<h3 class="elementor-heading-title elementor-size-default">耦合型</h3>				</div>
				</div>
		<div class="elementor-element elementor-element-d58a264 e-con-full e-flex e-con e-child" data-id="d58a264" data-element_type="container" data-e-type="container">
				<div class="elementor-element elementor-element-50c8ca5 elementor-widget elementor-widget-image" data-id="50c8ca5" data-element_type="widget" data-e-type="widget" data-widget_type="image.default">
															<img loading="lazy" decoding="async" width="500" height="500" src="https://www.zhanfengdesign.com/wp-content/uploads/2026/05/ycwdbsq-1-e1779153801181.webp" class="attachment-large size-large wp-image-6974" alt="4G远传型" />															</div>
				<div class="elementor-element elementor-element-7730420 elementor-widget elementor-widget-heading" data-id="7730420" data-element_type="widget" data-e-type="widget" data-widget_type="heading.default">
					<h3 class="elementor-heading-title elementor-size-default">4G远传型</h3>				</div>
				</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-a0b49bd e-flex e-con-boxed e-con e-parent" data-id="a0b49bd" data-element_type="container" data-e-type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-6177ac3 elementor-widget elementor-widget-heading" data-id="6177ac3" data-element_type="widget" data-e-type="widget" data-widget_type="heading.default">
					<h2 class="elementor-heading-title elementor-size-default">温度变送器特点</h2>				</div>
				<div class="elementor-element elementor-element-c92dc1e elementor-widget elementor-widget-text-editor" data-id="c92dc1e" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
									<p>1、采用环氧树脂密封结构，因此抗震、耐温，适合在恶劣现场环境中安装使用。<br />2、现场安装于热电阻、热电偶的接线盒内，直接输出4~20mA，这样既省去较贵的补偿导线费用，又提高了信号长距离传送过程中的抗干扰能力。<br />3、精度高、功耗低、使用环境温度范围宽、工作稳定可靠。<br />4、量程可调，并具有线性化较正功能，热电偶变送器具有冷端自动补偿功能。<br />应用面广，既可与热电偶、热电阻形成一体化现场安装结构，也可作为功能模块安装入检测设备中。</p>								</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-372bc3e e-flex e-con-boxed e-con e-parent" data-id="372bc3e" data-element_type="container" data-e-type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-3523bcb elementor-widget elementor-widget-heading" data-id="3523bcb" data-element_type="widget" data-e-type="widget" data-widget_type="heading.default">
					<h2 class="elementor-heading-title elementor-size-default">主要技术指标</h2>				</div>
				<div class="elementor-element elementor-element-9ba3145 elementor-widget elementor-widget-text-editor" data-id="9ba3145" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
									<p>1、输入：热电阻Pt100、Cu50、Cu100，热电偶K、E、S、B、T、J、N<br />2、输出：在量程范围内输出4~20mA直流信号可与热电阻温度计的输出电阻信号成线性，可与热电阻温度计的输入温度信号成线性；可与热电偶输入的毫伏信号成线性，也可与热电偶温度计的输入温度信号成线性。<br />3、基本误差：±0.2%、±0.5%<br />4、传送方式：二线制<br />5、变送器工作电源电压最低12V，最高35V，额定工作电压24V。<br />6、负载：极限负载电阻按下式计算，RL（max）=50×（Vmm-12）(即24V时负载电阻可在0~600Ω范围内选用)额定负载250Ω。<br />注：量程可调式变送器，改变量程时零点与满度需反复调试；电偶型变送器在调试前须预热30分钟。<br />7、环境温度影响≤0.05%1℃<br />8、正常工作环境：<br />a、环境温度-25℃~+80℃<br />b、相对湿度5%~95%<br />c、机械振动f≤55Hz振幅&lt;0.15mm。</p>								</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-ff5ea78 e-flex e-con-boxed e-con e-parent" data-id="ff5ea78" data-element_type="container" data-e-type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-43af054 elementor-widget elementor-widget-heading" data-id="43af054" data-element_type="widget" data-e-type="widget" data-widget_type="heading.default">
					<h2 class="elementor-heading-title elementor-size-default">型号、类别</h2>				</div>
				<div class="elementor-element elementor-element-d42b885 elementor-widget elementor-widget-tablepress-table" data-id="d42b885" data-element_type="widget" data-e-type="widget" data-widget_type="tablepress-table.default">
					
<table id="tablepress-74" class="tablepress tablepress-id-74">
<thead>
<tr class="row-1">
	<th class="column-1">型号</th><th class="column-2">传感器分度号</th><th class="column-3">最大量程规定</th><th class="column-4">规定最小量程范围（上限下限之差）</th>
</tr>
</thead>
<tbody class="row-striping row-hover">
<tr class="row-2">
	<td class="column-1">SBWR-2160</td><td class="column-2">E</td><td class="column-3">0~800℃</td><td class="column-4">300℃</td>
</tr>
<tr class="row-3">
	<td class="column-1">SBWR-2260</td><td class="column-2">K</td><td class="column-3">0~1300℃</td><td class="column-4">400℃</td>
</tr>
<tr class="row-4">
	<td class="column-1">SBWR-2360</td><td class="column-2">S</td><td class="column-3">0~1600℃</td><td class="column-4">600℃</td>
</tr>
<tr class="row-5">
	<td class="column-1">SBWR-2460</td><td class="column-2">B</td><td class="column-3">0~1800℃</td><td class="column-4">800℃</td>
</tr>
<tr class="row-6">
	<td class="column-1">SBWR-2560</td><td class="column-2">T</td><td class="column-3">0~400℃</td><td class="column-4">200℃</td>
</tr>
<tr class="row-7">
	<td class="column-1">SBWR-2660</td><td class="column-2">J</td><td class="column-3">0~1200℃</td><td class="column-4">300℃</td>
</tr>
<tr class="row-8">
	<td class="column-1">SBWR-2760</td><td class="column-2">N</td><td class="column-3">0~1200℃</td><td class="column-4">400℃</td>
</tr>
<tr class="row-9">
	<td class="column-1">SBWR-4160</td><td class="column-2">E</td><td class="column-3">0~800℃</td><td class="column-4">300℃</td>
</tr>
<tr class="row-10">
	<td class="column-1">SBWR-4260</td><td class="column-2">K</td><td class="column-3">0~1300℃</td><td class="column-4">400℃</td>
</tr>
<tr class="row-11">
	<td class="column-1">SBWR-4360</td><td class="column-2">S</td><td class="column-3">0~1600℃</td><td class="column-4">600℃</td>
</tr>
<tr class="row-12">
	<td class="column-1">SBWR-4460</td><td class="column-2">B</td><td class="column-3">0~1800℃</td><td class="column-4">800℃</td>
</tr>
<tr class="row-13">
	<td class="column-1">SBWR-4560</td><td class="column-2">T</td><td class="column-3">0~400℃</td><td class="column-4">200℃</td>
</tr>
<tr class="row-14">
	<td class="column-1">SBWR-4660</td><td class="column-2">J</td><td class="column-3">0~1200℃</td><td class="column-4">300℃</td>
</tr>
<tr class="row-15">
	<td class="column-1">SBWR-4760</td><td class="column-2">N</td><td class="column-3">0~1200℃</td><td class="column-4">400℃</td>
</tr>
<tr class="row-16">
	<td class="column-1">SBWR-2160</td><td class="column-2">Cu50</td><td class="column-3">-50~150℃</td><td class="column-4">50℃</td>
</tr>
<tr class="row-17">
	<td class="column-1">SBWR-2260</td><td class="column-2">Cu100</td><td class="column-3">-50~150℃</td><td class="column-4">50℃</td>
</tr>
<tr class="row-18">
	<td class="column-1">SBWR-2460</td><td class="column-2">Pt100</td><td class="column-3">0~600℃</td><td class="column-4">50℃</td>
</tr>
<tr class="row-19">
	<td class="column-1">SBWR-2460</td><td class="column-2">Pt100</td><td class="column-3">-100~200℃</td><td class="column-4">50℃</td>
</tr>
<tr class="row-20">
	<td class="column-1">SBWR-4460</td><td class="column-2">Pt100</td><td class="column-3">-200~600℃</td><td class="column-4">50℃</td>
</tr>
</tbody>
</table>
				</div>
				<div class="elementor-element elementor-element-fb018b8 elementor-widget elementor-widget-tablepress-table" data-id="fb018b8" data-element_type="widget" data-e-type="widget" data-widget_type="tablepress-table.default">
					
<table id="tablepress-75" class="tablepress tablepress-id-75 tbody-has-connected-cells">
<thead>
<tr class="row-1">
	<th class="column-1">S</th><th colspan="3" class="column-2">表示DDZ-S系列电动单元组合仪表</th>
</tr>
</thead>
<tbody class="row-striping row-hover">
<tr class="row-2">
	<td class="column-1">B</td><td colspan="3" class="column-2">变送单元</td>
</tr>
<tr class="row-3">
	<td class="column-1">W</td><td colspan="3" class="column-2">温度</td>
</tr>
<tr class="row-4">
	<td rowspan="2" class="column-1">▢</td><td class="column-2">Z</td><td colspan="2" class="column-3">热电阻</td>
</tr>
<tr class="row-5">
	<td class="column-2">R</td><td colspan="2" class="column-3">热电偶</td>
</tr>
<tr class="row-6">
	<td rowspan="2" class="column-1">▢</td><td class="column-2">2</td><td colspan="2" class="column-3">输出与对应温度呈线性</td>
</tr>
<tr class="row-7">
	<td class="column-2">4</td><td colspan="2" class="column-3">输出与对应输入电信号呈线性</td>
</tr>
<tr class="row-8">
	<td rowspan="10" class="column-1">▢</td><td rowspan="7" class="column-2">热电偶</td><td class="column-3">1</td><td class="column-4">E</td>
</tr>
<tr class="row-9">
	<td class="column-3">2</td><td class="column-4">K</td>
</tr>
<tr class="row-10">
	<td class="column-3">3</td><td class="column-4">S</td>
</tr>
<tr class="row-11">
	<td class="column-3">4</td><td class="column-4">B</td>
</tr>
<tr class="row-12">
	<td class="column-3">5</td><td class="column-4">T</td>
</tr>
<tr class="row-13">
	<td class="column-3">6</td><td class="column-4">J</td>
</tr>
<tr class="row-14">
	<td class="column-3">7</td><td class="column-4">N</td>
</tr>
<tr class="row-15">
	<td rowspan="3" class="column-2">热电阻</td><td class="column-3">1</td><td class="column-4">Cu50</td>
</tr>
<tr class="row-16">
	<td class="column-3">2</td><td class="column-4">Cu100</td>
</tr>
<tr class="row-17">
	<td class="column-3">4</td><td class="column-4">Pt100</td>
</tr>
<tr class="row-18">
	<td rowspan="2" class="column-1">▢</td><td class="column-2">6</td><td colspan="2" class="column-3">一体化安装</td>
</tr>
<tr class="row-19">
	<td class="column-2">8</td><td colspan="2" class="column-3">隔离安装</td>
</tr>
<tr class="row-20">
	<td rowspan="2" class="column-1">▢</td><td class="column-2">0</td><td colspan="2" class="column-3">普通型</td>
</tr>
<tr class="row-21">
	<td class="column-2">1</td><td colspan="2" class="column-3">隔离型</td>
</tr>
<tr class="row-22">
	<td rowspan="4" class="column-1">▢</td><td class="column-2">A</td><td colspan="2" class="column-3">带指针表头</td>
</tr>
<tr class="row-23">
	<td class="column-2">B</td><td colspan="2" class="column-3">带液晶显示</td>
</tr>
<tr class="row-24">
	<td class="column-2">C</td><td colspan="2" class="column-3">挂壁安装</td>
</tr>
<tr class="row-25">
	<td class="column-2">D</td><td colspan="2" class="column-3">导轨安装</td>
</tr>
</tbody>
</table>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-aaca702 e-flex e-con-boxed e-con e-parent" data-id="aaca702" data-element_type="container" data-e-type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-f70f14d elementor-widget elementor-widget-heading" data-id="f70f14d" data-element_type="widget" data-e-type="widget" data-widget_type="heading.default">
					<h2 class="elementor-heading-title elementor-size-default">接线方式</h2>				</div>
				<div class="elementor-element elementor-element-2dfb824 elementor-widget elementor-widget-text-editor" data-id="2dfb824" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
									<p>热电阻三线制变送器安装接线图</p>								</div>
				<div class="elementor-element elementor-element-0d50b23 elementor-widget elementor-widget-image" data-id="0d50b23" data-element_type="widget" data-e-type="widget" data-widget_type="image.default">
															<img loading="lazy" decoding="async" width="600" height="220" src="https://www.zhanfengdesign.com/wp-content/uploads/2026/05/rdzjx-e1779153829973.webp" class="attachment-large size-large wp-image-6976" alt="三线制变送器安装接线图" />															</div>
				<div class="elementor-element elementor-element-9e3127d elementor-widget elementor-widget-text-editor" data-id="9e3127d" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
									<p>热电偶变送器安装接线图</p>								</div>
				<div class="elementor-element elementor-element-a0e08f2 elementor-widget elementor-widget-image" data-id="a0e08f2" data-element_type="widget" data-e-type="widget" data-widget_type="image.default">
															<img loading="lazy" decoding="async" width="600" height="214" src="https://www.zhanfengdesign.com/wp-content/uploads/2026/05/rdojx-e1779153841901.webp" class="attachment-large size-large wp-image-6977" alt="变送器安装接线图" />															</div>
				<div class="elementor-element elementor-element-f3e5207 elementor-widget elementor-widget-text-editor" data-id="f3e5207" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
									<p>导轨式电偶变送器安装接线图</p>								</div>
				<div class="elementor-element elementor-element-746341c elementor-widget elementor-widget-image" data-id="746341c" data-element_type="widget" data-e-type="widget" data-widget_type="image.default">
															<img loading="lazy" decoding="async" width="600" height="249" src="https://www.zhanfengdesign.com/wp-content/uploads/2026/05/dgsdojx-e1779153851719.webp" class="attachment-large size-large wp-image-6978" alt="导轨式电偶变送器安装接线图" />															</div>
				<div class="elementor-element elementor-element-a981b1a elementor-widget elementor-widget-text-editor" data-id="a981b1a" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
									<p>导轨式电阻变送器安装接线图</p>								</div>
				<div class="elementor-element elementor-element-088ad51 elementor-widget elementor-widget-image" data-id="088ad51" data-element_type="widget" data-e-type="widget" data-widget_type="image.default">
															<img loading="lazy" decoding="async" width="600" height="235" src="https://www.zhanfengdesign.com/wp-content/uploads/2026/05/dgsdzjx-e1779153863922.webp" class="attachment-large size-large wp-image-6979" alt="导轨式电阻变送器安装接线图" />															</div>
				<div class="elementor-element elementor-element-48236c8 elementor-widget elementor-widget-text-editor" data-id="48236c8" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
									<p>一体化液晶显示变送器接线图</p>								</div>
				<div class="elementor-element elementor-element-1724b38 elementor-widget elementor-widget-image" data-id="1724b38" data-element_type="widget" data-e-type="widget" data-widget_type="image.default">
															<img loading="lazy" decoding="async" width="600" height="254" src="https://www.zhanfengdesign.com/wp-content/uploads/2026/05/ythyjxsjx-e1779153875107.webp" class="attachment-large size-large wp-image-6980" alt="一体化液晶显示变送器接线图" />															</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-d38ea09 e-flex e-con-boxed e-con e-parent" data-id="d38ea09" data-element_type="container" data-e-type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-3a09078 elementor-widget elementor-widget-heading" data-id="3a09078" data-element_type="widget" data-e-type="widget" data-widget_type="heading.default">
					<h2 class="elementor-heading-title elementor-size-default">信号隔离器</h2>				</div>
				<div class="elementor-element elementor-element-499db6a elementor-widget elementor-widget-text-editor" data-id="499db6a" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
									<p>1、SBWZ/R系列信号隔离器主要与DCS、PLC等工业测控系统配合使用，用来完善和补充系统模拟I/O插件功能，增加系统适用性和现场环境下的可靠性。本产品按国际电磁兼容性标准设计，采用国际上同行业公认的调制式变压器隔离技术，完成输入、输出、电源的相互隔离。在模块内部电路设计上，以低功耗，低温漂技术为基础，采用高品质元器件，使产品能够长期稳定工作，同时产品设有输入保护、干扰抑制、隔离等功能。<br />2、技术参数<br />测量精度：±0.5F·S%或±0.2F·S%<br />输入信号：各种直流线性信号<br />输出信号：一进一出或一进两出<br />工作电源：DC24V<br />工作环境：0~50℃，相对温度≤85%，无腐蚀气体，无强烈震动场合。<br />输入阻抗：230Ω+输出负载电阻<br />输出负载电阻：50~500Ω<br />隔 离：输入、输出、电源间相互隔离<br />绝缘电阻：电源、输入、输出端子间≥100MΩ<br />绝缘强度：电源、输入、输出端子间1000VDC/分钟</p>								</div>
				<div class="elementor-element elementor-element-2432905 elementor-widget elementor-widget-heading" data-id="2432905" data-element_type="widget" data-e-type="widget" data-widget_type="heading.default">
					<h2 class="elementor-heading-title elementor-size-default">热电偶变送器校验步骤</h2>				</div>
				<div class="elementor-element elementor-element-7d26a9b elementor-widget elementor-widget-text-editor" data-id="7d26a9b" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
									<p>1、校验时，在输入端接入电位差计，输出信号为电动势，在输出端接上24VDC稳压电源并串接上标准电流表。<br />2、调零：反接信号输入线，使电位差计输出校验现场室温对应电动势，调整电位器Z，使电流表读数为4mA。<br />3、调满：正接信号输入线，使电位差计输出满量程对应电动势，调整电位器S，使电流表读数为20mA。（该电动势为满度电动势减去室温对应电动势后的值）<br />例： 在检验现场室温为7℃，输入信号为K，量程为0~1000℃的变送器标定，通过查表得知7℃对应电动势为0.277mV，1000℃对应电动势为41.269mV，反接后，电位差计输出0.277mV，调整电位器Z，使电流表读数为4mA；正接线后电位差计输出读数为40.992mV（41.269mV~0.277mV），调整电位器S，使电流表读数为20mA。</p>								</div>
				<div class="elementor-element elementor-element-e13fc61 elementor-widget elementor-widget-heading" data-id="e13fc61" data-element_type="widget" data-e-type="widget" data-widget_type="heading.default">
					<h2 class="elementor-heading-title elementor-size-default">热电阻变送器校验步骤</h2>				</div>
				<div class="elementor-element elementor-element-a56295d elementor-widget elementor-widget-text-editor" data-id="a56295d" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
									<p>1、标定时，按以上典型接线图接线，在输入端接入标准电阻箱（如ZX-25a），在输出端接上24VDC稳压电源并串接上标准电流表。<br />2、改变信号源发生器（电阻箱），使之等于量程的下限值，调整电位器Z，使电流表的读数为4 mA，改变信号源，使之等于量程的上限值，调整电位器S，使电流表的读数为20 mA即可。<br />例： 输入型号为Pt100量程为0~100℃的变送器。正确接线后，电阻箱输出100Ω，调整电位器Z，使电流表读数为4 mA；电阻箱输出读数为138.50Ω(即热电阻在100℃时对应的电阻值)，调整电位器S，使电流表的读数为20 mA。</p>								</div>
				<div class="elementor-element elementor-element-e14bb45 elementor-widget elementor-widget-heading" data-id="e14bb45" data-element_type="widget" data-e-type="widget" data-widget_type="heading.default">
					<h2 class="elementor-heading-title elementor-size-default">安装注意事项</h2>				</div>
				<div class="elementor-element elementor-element-91eda6c elementor-widget elementor-widget-text-editor" data-id="91eda6c" data-element_type="widget" data-e-type="widget" data-widget_type="text-editor.default">
									<p>安装核心是选对测点、插深到位、密封牢固、屏蔽接地、远离干扰，直接决定测量精度与寿命。<br />一、安装前准备<br />核对型号：确认量程、分度号（Pt100/K 型）、输出（4-20mA）、防爆 / 防护等级（IP65/IP68）与现场匹配。<br />外观检查：探头无弯曲 / 划痕、接线盒完好、螺纹 / 法兰无损伤、防爆面无锈蚀。<br />工艺条件：管道吹扫干净、无焊渣 / 杂物；高压 / 高温工况确认耐压等级，≥10MPa 需加保护套管。<br />二、测点位置选择（关键）<br />优先直管段：选上游≥10D、下游≥5D直管段，避开弯头、阀门、三通、泵口等流态不稳处。<br />代表性区域：测管道中心线（流速最高、温度最均匀）；避免死角、管壁、沉积区。<br />远离干扰：距电机、变频器、变压器等 **≥30cm**；避开直射热源 / 冷源、振动源。<br />环境适配：环境温度 &#8211; 20~+85℃、湿度≤85% RH；户外加防雨防晒罩，电气接口朝下防进水。<br />三、机械安装与固定<br />1）插入深度（核心精度项）<br />管道：插入至管径 1/3~1/2，确保感温元件在中心；DN≥50mm≥150mm，DN&lt;50mm 斜插 45°。<br />容器：插入介质 **≥50mm**，不碰罐壁 / 底板。<br />液体：垂直安装防气泡；倾斜≤30°、探头朝下。<br />气体：水平安装，防冷凝液积在探头。<br />2）安装方式与密封<br />螺纹（G1/2/NPT1/2）：缠3~5 圈生料带（不堵探头），扭矩 20~30N・m；只拧底部螺帽，不转表头（防内部线断）。<br />法兰：密封垫匹配介质 / 压力，螺栓对称均匀拧紧，做气密性试验。<br />管夹式（外壁测温）：管壁清洁平整、贴合紧密；适用于 DN≤50、导热好的管道。<br />振动场合：加减震支架、防松螺母，定期检查紧固。<br />四、电气接线与接地（防干扰）<br />电源：DC 24V±10%，严禁反接；单独供电，不与强电共用回路。<br />信号线：用屏蔽双绞线，与动力电缆分开敷设（间距≥30cm）；屏蔽层单端接地（控制室侧），不形成地环路。<br />热电阻（Pt100）：三线制，线阻≤1Ω、三线电阻平衡；热电偶：正负极不可接反。<br />接地：外壳可靠接地，接地电阻 **≤4Ω**；防爆区严格按本安 / 隔爆规范，用防爆电缆与密封接头。<br />五、防爆与特殊工况<br />防爆区：选Ex d/ia IIC T6等匹配等级；密封到位、电缆引入防爆密封接头，多余接口用防爆堵头封死。<br />高温（&gt;200℃）：垂直安装防套管变形；加散热片，降低表头温度。<br />腐蚀介质：选 316L / 哈氏合金探头，防腐密封，定期检查腐蚀。<br />六、投运与维护<br />投运前：复查接线、绝缘电阻≥20MΩ、无泄漏；通电预热 15~30min，零点 / 量程校准。<br />日常维护：定期检查紧固、密封、接线；探头结垢 / 腐蚀及时清洗或更换；避免化学品擦敏感部件。<br />七、常见禁忌（避坑）<br />❌ 装在弯头 / 阀门后、管道死角、管壁处。<br />❌ 插入过浅（未到中心）或过深（碰管壁 / 堵塞）。<br />❌ 与强电同槽、屏蔽层两端接地、电源反接。<br />❌ 旋转表头紧固、生料带过多堵探头。<br />❌ 普通型用于防爆区、户外无防护。</p>								</div>