<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>热式气体质量流量计技术文章 - 金湖凯铭仪表</title>
	<atom:link href="https://www.zhanfengdesign.com/category/article/llyb-article/rsqtzlllj-article/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.zhanfengdesign.com/category/article/llyb-article/rsqtzlllj-article/</link>
	<description>流量&#124;液位&#124;温度&#124;压力</description>
	<lastBuildDate>Mon, 12 Oct 2026 06:59:11 +0000</lastBuildDate>
	<language>zh-Hans</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://www.zhanfengdesign.com/wp-content/uploads/2026/05/elementor/thumbs/微信图片_20250805143107_120_3-rmwn996852eavbnmbpepzofwfik8mes0k2lm3lqvvs.png</url>
	<title>热式气体质量流量计技术文章 - 金湖凯铭仪表</title>
	<link>https://www.zhanfengdesign.com/category/article/llyb-article/rsqtzlllj-article/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>dn100 热式气体质量流量计怎么选</title>
		<link>https://www.zhanfengdesign.com/9891/</link>
					<comments>https://www.zhanfengdesign.com/9891/#respond</comments>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Mon, 12 Oct 2026 06:58:19 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[流量仪表技术文章]]></category>
		<category><![CDATA[热式气体质量流量计技术文章]]></category>
		<category><![CDATA[流量仪表]]></category>
		<category><![CDATA[热式气体质量流量计]]></category>
		<guid isPermaLink="false">https://www.zhanfengdesign.com/?p=9891</guid>

					<description><![CDATA[<p>一、引言在压缩空气、氮气、天然气等气体计 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/9891/">dn100 热式气体质量流量计怎么选</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph"><strong>一、引言</strong><br>在压缩空气、氮气、天然气等气体计量中，热式气体质量流量计以直接测量质量流量、无需温压补偿、量程比宽、低压损的特点受到广泛应用。其中 <a href="https://www.zhanfengdesign.com/rsqtzlllj/">dn100 热式气体质量流量计</a>作为公称通径 100mm 的中小口径仪表，常用于车间供气支管、空压机出口、工艺气体管路等场景。很多工程人员在选型时，只关注口径与量程，忽略介质特性、安装条件、输出需求，导致仪表投用后计量偏差大、信号不稳定、维护频繁。本文围绕 dn100 热式气体质量流量计的选型方法，从测量原理、工况确认、量程核算、结构形式、安装条件、信号输出等角度展开讲解，为工程选型提供系统参考。</p>



<p class="wp-block-paragraph"><strong>二、明确测量原理与适用场景</strong><br>dn100 热式气体质量流量计基于热扩散原理，通过加热元件与测温元件检测气体流过热探头的热量损耗，换算质量流量。它直接输出质量流量，不受压力、温度波动影响，适合变工况、低流速、宽范围气体计量。选型前应先确认应用是否匹配：若测量介质为干燥洁净气体、流量范围宽、存在低负荷工况，热式仪表优势明显；若介质含尘含湿严重、组分剧烈变化，则需评估探头污染对测量稳定性的影响。</p>



<p class="wp-block-paragraph"><strong>三、确认工况参数与介质特性</strong><br><strong>3.1 介质种类与物性</strong><br>不同气体的导热系数、比热容、密度不同，直接影响热式流量计的测量灵敏度与量程。选型前需明确介质名称，按实际物性设定参数。介质组分变化、含水含尘会改变热扩散特性，投用前应依据实测物性数据进行标定或修正。</p>



<p class="wp-block-paragraph"><strong>3.2 温度与压力范围</strong><br>虽然质量流量不受温压波动影响，但工况温度变化会改变介质热物性，影响探头灵敏度与量程边界。选型需核对仪表耐温范围，确认覆盖现场最高、最低温度。压力主要影响介质密度与标况体积流量换算，需明确工作压力用于量程核算。</p>



<p class="wp-block-paragraph"><strong>3.3 流量范围与计量单位</strong><br>明确瞬时流量最大值、最小值及常用流量，确认计量单位是质量流量还是标况体积流量。日常稳定流量宜落在量程的 20%～80% 区间，最小流量应高于量程下限，最大持续流量低于量程上限，保障计量精度与使用寿命。</p>



<p class="wp-block-paragraph"><strong>四、选择合适的结构形式</strong><br>dn100 热式气体质量流量计有插入式与管段式两种结构。管段式仪表传感器与流道整体标定，精度较高，需断开管道串联安装，适合可停气安装、精度要求高的计量场合。插入式仪表探针直接插入管道，可带压开孔、在线维护，压损低，适合大口径、连续生产、强调不停气维护的工况。dn100 口径下，若现场可停气且精度要求高，宜选管段式；若为连续生产管道、强调维护便捷，插入式更为合适。</p>



<p class="wp-block-paragraph"><strong>五、评估安装条件与流场要求</strong><br>热式流量计对来流流场较为敏感。dn100 热式气体质量流量计上游需保证足够直管段，避免弯头、阀门、变径处安装引起的流场畸变影响探头热扩散信号稳定。上游存在异形管件时需加长直管段或加装整流器。安装位置应避开强振动、强电磁干扰区域，探头应伸入流场充分接触气流，插入式仪表需确认插入深度与安装角度。</p>



<p class="wp-block-paragraph"><strong>六、确认信号输出与自控对接</strong><br>结合自控系统接口要求，确认 dn100 热式气体质量流量计的输出方式。常见输出包括 4-20mA 模拟量、脉冲量及 RS485、Modbus 数字通讯。4-20mA 用于实时读取瞬时质量流量，适合工艺监控；数字通讯可同时读取瞬时流量、累积流量、介质温度等多组参数，便于数据采集与集中管理。贸易计量或需数据审计的场合，宜选配数字通讯与累积流量功能。</p>



<p class="wp-block-paragraph"><strong>七、关注材质、防爆与防护要求</strong><br>依据介质特性与工况环境，选择合适的探头材质与结构材质。腐蚀性气体需选用耐蚀材质；高温工况核对仪表耐温等级。易燃易爆气体计量场景，需确认 dn100 热式气体质量流量计防爆等级与现场危险区域、介质组别匹配，并选配合格防爆格兰与接线附件。户外安装选用适当防护等级，防止雨水、粉尘影响电气性能。</p>



<p class="wp-block-paragraph"><strong>八、总结</strong><br>dn100 热式气体质量流量计选型需综合介质物性、工况温度压力、流量范围、结构形式、安装流场、信号输出、材质与防爆要求系统评估。核心是明确计量单位、正确核算量程、匹配结构形式、保证安装流场、对接信号需求，并依据介质与防爆要求选配材质。完整收集现场工况参数进行核算，规范安装并正确设定物性参数，方能充分发挥仪表计量性能，保障长期稳定运行。</p>
<p><a href="https://www.zhanfengdesign.com/9891/">dn100 热式气体质量流量计怎么选</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.zhanfengdesign.com/9891/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>大口径烟气管道插入式耐高温热式气体质量流量计选用</title>
		<link>https://www.zhanfengdesign.com/9521/</link>
					<comments>https://www.zhanfengdesign.com/9521/#respond</comments>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Wed, 22 Jul 2026 08:07:06 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[热式气体质量流量计技术文章]]></category>
		<category><![CDATA[流量仪表]]></category>
		<category><![CDATA[热式气体质量流量计]]></category>
		<guid isPermaLink="false">https://www.zhanfengdesign.com/?p=9521</guid>

					<description><![CDATA[<p>工业锅炉、焚烧炉等设备的大口径烟气管道， [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/9521/">大口径烟气管道插入式耐高温热式气体质量流量计选用</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">工业锅炉、焚烧炉等设备的大口径烟气管道，具备管径大、介质温度高、含粉尘杂质多、流场复杂的特点，常规计量设备适配性较差。<a href="https://www.zhanfengdesign.com/rsqtzlllj/">热式气体质量流量计</a>可直接测量气体质量流量，无需温压补偿，是烟气工况监测的优选设备。</p>



<p class="wp-block-paragraph">一、耐高温工况核心选型思路<br>烟气管道长期处于高温运行状态，瞬时温度波动幅度较大，选用设备需匹配现场实际高温区间，核心传感探头、探杆材质需具备优异的耐高温、抗热老化性能，可长期耐受烟气持续高温冲刷。同时需区分长期恒温与间歇高温工况，避免普通常温型传感元件长期高温工作出现零点漂移、元件老化失效问题，保障高温环境下计量稳定性，满足烟气排放监测、工况数据分析需求。</p>



<p class="wp-block-paragraph">二、大口径管道适配结构选用要点<br>大口径烟气管道管径尺寸大，采用传统管段式设备成本高、施工难度大，因此优先选用插入式结构。该结构无需切断管道、无需整体更换管路，可实现不停产开孔安装，大幅降低改造施工成本与停工损耗。选型时需根据管道直径匹配适配的探杆插入深度，保证传感探头处于管道中心有效流速区域，规避管壁低速流场干扰，确保采集的流量数据贴合管道整体烟气流通状态。</p>



<p class="wp-block-paragraph">三、粉尘烟气工况防护选型标准<br>工业烟气普遍含有粉煤灰、细微粉尘等杂质，长期附着会遮挡传感探头，影响热交换与信号采集。选用设备需配备防尘防护结构，探头采用防积尘设计，减少粉尘附着堆积；同时支持现场可拆卸清洗结构，运维人员可定期抽出探头清洁维护，无需整体拆除设备。杜绝粉尘包裹探头引发的计量偏低、数据跳变等故障，适配烟气长期恶劣介质工况。</p>



<p class="wp-block-paragraph">四、流场与量程适配选用原则<br>大口径烟气管道内部流场紊乱，弯头、变径、风机启停会造成流速波动不均。选型需优先宽量程设备，兼顾低流速待机工况与高流速满负荷排烟工况，消除测量盲区。同时设备需具备优异的流场抗干扰能力，对烟气紊流、流速分层等复杂工况适应性强，无需严格预留超长直管段，适配工业管道安装空间有限、管路布局复杂的现状。</p>



<p class="wp-block-paragraph">五、环境与电气安全选型要求<br>烟气管道多布置于户外厂房、炉顶高温区域，设备外壳需具备防尘、防水、抗高温老化的防护能力，耐受户外温差变化与恶劣环境侵蚀。电气模块需具备良好的抗电磁干扰性能，可抵御风机、变频器等周边设备的信号干扰，避免流量数据异常波动，保障长期连续稳定采集数据。</p>



<p class="wp-block-paragraph">六、运维与数据适配选用思路<br>选用支持标准通讯信号输出的设备，可无缝对接厂区环保监测系统与工控平台，实现烟气流量数据实时上传、存储与溯源。设备结构简洁，无需频繁校准维护，适配工业烟气24小时连续排放的运行模式，有效降低后期运维工作量，满足环保监测、设备工况核算的长期使用需求。</p>



<p class="wp-block-paragraph">选用总结<br>大口径高温烟气管道选型，需围绕耐高温性能、插入式适配结构、防尘防护、抗干扰能力四大核心维度综合考量，贴合烟气复杂恶劣工况。合理选型可有效规避高温、粉尘、流场紊乱带来的计量误差，保障热式气体质量流量计长期稳定、精准完成烟气流量监测工作。</p>
<p><a href="https://www.zhanfengdesign.com/9521/">大口径烟气管道插入式耐高温热式气体质量流量计选用</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.zhanfengdesign.com/9521/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>防爆管段式热式气体质量流量计天然气选配规范</title>
		<link>https://www.zhanfengdesign.com/9381/</link>
					<comments>https://www.zhanfengdesign.com/9381/#respond</comments>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Sun, 12 Jul 2026 02:51:56 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[热式气体质量流量计技术文章]]></category>
		<category><![CDATA[流量仪表]]></category>
		<category><![CDATA[热式气体质量流量计]]></category>
		<guid isPermaLink="false">https://www.zhanfengdesign.com/?p=9381</guid>

					<description><![CDATA[<p>天然气输送厂区、锅炉房、燃气调压站均属于 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/9381/">防爆管段式热式气体质量流量计天然气选配规范</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">天然气输送厂区、锅炉房、燃气调压站均属于易燃易爆危险工况，介质组分稳定但管网温压波动明显，常规体积式仪表必须配套温压补偿模块，增加设备故障点，不利于燃气能耗精准统计。热式质量流量检测设备可直接输出标准质量流量，无需额外补偿组件，适配中小口径燃气主管计量场景，<a href="https://www.zhanfengdesign.com/rsqtzlllj/">防爆管段式热式气体质量流量计</a>集成隔爆外壳、一体化测量管体，是工业天然气计量安全合规的核心配套仪表。</p>



<p class="wp-block-paragraph">一、天然气工况选配基础要求</p>



<ol class="wp-block-list">
<li>介质属性：天然气以甲烷为主，含有微量水汽、轻质杂质，供气压力0.1~1.6MPa，四季温度变化大，昼夜用气负荷差距明显；</li>



<li>安全标准：燃气区域电气仪表必须具备完整防爆资质，杜绝电路火花引发燃爆风险，符合安监与燃气管道验收规范；</li>



<li>计量需求：直接获取标况质量流量，用于车间能耗核算、锅炉燃气配比、厂区用气总量统计，数据需连续稳定、无大幅漂移；</li>



<li>安装条件：中小口径规整管道，具备充足直管段，管路洁净度较高，可停水停气短时间施工。</li>
</ol>



<p class="wp-block-paragraph">二、防爆等级与壳体选配硬性规范<br>天然气爆炸环境统一选用<strong>Ex d IIC T6</strong>隔爆整机，仪表检测腔体、转换显示仓独立密封隔离，油气无法渗入电路板内部。出线口配置防爆填料函，线缆缝隙完全封堵，防止可燃气体沿线路窜入机芯。<br>整机防护等级不低于IP65，抵御户外露天管廊雨水、粉尘侵蚀，冬季低温、夏季高温环境下内部电路不会凝露短路。禁止选用本安简易防爆型号作为燃气主管计量设备，安全裕度无法满足持续输气工况。</p>



<p class="wp-block-paragraph">三、管段本体与传感探头材质选配<br>管段本体选用304不锈钢一体成型结构，法兰标准匹配燃气管道通用PN16压力等级，焊缝严密无渗漏，耐天然气微量硫化物轻微腐蚀。<br>传感探头选用高稳定铂热电阻组件，表面做防油污涂层处理，不易吸附天然气中轻质胶质杂质；探头支撑件为316L不锈钢，抗气流冲击、不易变形，长期连续输送不会出现信号衰减，保障计量重复性。针对含微量粉尘的上游来气管路，仪表前端需配套精密燃气过滤器，减少杂质附着探头。</p>



<p class="wp-block-paragraph">四、测量性能参数选配标准</p>



<ol class="wp-block-list">
<li>量程比：优先选用100:1超宽量程机型，覆盖锅炉保温低流量、满负荷燃烧高流量全部工况，消除小流量测量盲区；</li>



<li>测量原理优势：直接测量气体质量流量，不受管网温度、压力波动干扰，无需加装独立温压积算仪，简化现场配套设备；</li>



<li>精度等级：厂区能耗统计选用1.0级，燃气分户、车间成本精细核算可升级0.5级高精度配置，满足长期数据对比需求；</li>



<li>介质适配：出厂标定适配甲烷组分天然气，若存在混掺氮气、二氧化碳工况，需提前校准组分修正系数，避免系统偏差。</li>
</ol>



<p class="wp-block-paragraph">五、结构与安装选配要点</p>



<ol class="wp-block-list">
<li>直管段要求：管段式仪表对流场均匀度要求高，上游≥10DN、下游≥5DN平直管道，远离调压阀、弯头、泵体等紊流部件；</li>



<li>安装姿态：水平管道居中安装，避免管底积水、管顶积气覆盖传感探头；高点管路配套自动排气阀，消除气泡干扰流量信号；</li>



<li>管路密封：法兰四氟耐油垫片均匀压紧，防止天然气渗漏，防爆仪表接线仓施工完成后务必锁紧密封端盖；</li>



<li>布线规范：使用防爆屏蔽电缆，单独接地，与大功率风机、变频器动力电缆分开敷设，降低电磁干扰导致的数据跳变。</li>
</ol>



<p class="wp-block-paragraph">六、信号输出与燃气自控配套<br>标配4-20mA模拟信号，实时上传瞬时质量流量至PLC、DCS系统；搭载RS485 Modbus通讯，支持多台仪表组网，集中采集全厂各支路燃气消耗数据。<br>机身防爆液晶就地显示瞬时流量、累积总量、介质温度，断电累积数据自动保存，方便运维人员现场抄表对账，无需依托中控后台查看。</p>



<p class="wp-block-paragraph">七、日常运维长效保障方案<br>仪表无机械转动部件，无磨损损耗，基础运维工作量低。每月检查过滤器压差、法兰有无渗漏；每半年查看探头积污情况，积尘轻微可在线吹扫清理；每年送至计量机构校准，维持仪表出厂精度。<br>长期停机检修时关闭前后截止阀，放空管段内天然气，避免介质长期滞留腐蚀传感组件，延长仪表稳定使用周期。</p>



<p class="wp-block-paragraph">八、选配总结<br>工业天然气中小口径管道计量选型，优先从隔爆安全、不锈钢一体管体、宽量程质量直测三大维度匹配设备。搭配前置过滤、规范直管段安装、防爆屏蔽布线，可彻底解决传统体积式仪表温压补偿繁琐、数据偏差大、防爆性能不足等问题，稳定完成厂区燃气能耗监测、成本核算工作，适配锅炉房、化工支线、燃气调压站各类天然气输送工况。</p>
<p><a href="https://www.zhanfengdesign.com/9381/">防爆管段式热式气体质量流量计天然气选配规范</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.zhanfengdesign.com/9381/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>热式气体质量流量计选型参考要素，气体介质与现场工况匹配梳理</title>
		<link>https://www.zhanfengdesign.com/9134/</link>
					<comments>https://www.zhanfengdesign.com/9134/#respond</comments>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Wed, 24 Jun 2026 09:17:45 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[热式气体质量流量计技术文章]]></category>
		<category><![CDATA[流量仪表]]></category>
		<category><![CDATA[热式气体质量流量计]]></category>
		<guid isPermaLink="false">https://www.zhanfengdesign.com/?p=9134</guid>

					<description><![CDATA[<p>一、气体介质相关选型要素 二、流量参数选 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/9134/">热式气体质量流量计选型参考要素，气体介质与现场工况匹配梳理</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">一、气体介质相关选型要素</p>



<ol class="wp-block-list">
<li>介质组分与测量基础特性<br><a href="https://www.zhanfengdesign.com/rsqtzlllj/">热式气体质量流量计</a>依靠气体热传导系数完成质量流量测算，不同组分气体导热参数存在差异，选型需明确介质组分。<br>1）单一洁净气体：空气、氮气、氩气、氧气等，可选用标准标定探头，设备出厂参数可直接适配；<br>2）多组分混合气体：沼气、烟气、混合工艺保护气，需提供各组分占比，用于主机内部参数标定设置；<br>3）易液化、高饱和蒸气压气体，工况温压变化易产生凝露，凝液附着传感探头会干扰热交换，需配套前置气液分离装置。</li>



<li>介质洁净程度<br>传感探头包含精密测温铂丝元件，粉尘、油雾、水汽附着会改变换热效率，引发测量偏移。<br>1）干燥无粉尘洁净工艺气体：选用常规裸探头结构，无需额外过滤配件；<br>2）含有微量粉尘、轻质油雾的烟气、沼气、窑炉助燃气：管路上游配套除尘过滤器，减少杂质附着探头；<br>3）高粉尘、大量油雾、高液滴混合气体，长期使用易造成探头失效，不建议选用该类仪表。</li>



<li>介质腐蚀属性<br>依据气体腐蚀成分匹配探头、探杆接触材质：<br>1）中性干燥气体（空气、氮气）：探杆选用 304 不锈钢；<br>2）含微量硫化物、弱腐蚀性工艺烟气、沼气：接触部件选用 316 不锈钢材质；<br>3）高酸性、强腐蚀工艺气体，会逐步腐蚀传感元件与探杆，难以长期稳定计量，可更换其他类型计量仪表。</li>
</ol>



<p class="wp-block-paragraph">二、流量参数选型要素</p>



<ol class="wp-block-list">
<li>量程匹配<br>1）统计管路日常最小、最大工况流量，常规工作流量建议处于仪表量程中段区间，测量状态更平稳；<br>2）核对仪表测量下限，管路长期流量低于下限会出现信号微弱、数据丢失；<br>3）微小微量气体管线，选用小量程专用热式探头；大流量通风、热风管道，匹配大量程插入式结构；<br>4）存在短时流量波动冲击工况，选型预留合理量程余量，避免长期满量程运行。</li>



<li>标准状态换算说明<br>热式流量计输出数值多为标况质量流量，选型时统一确认标况基准温度、压力，匹配工艺统计核算标准。</li>
</ol>



<p class="wp-block-paragraph">三、管道与安装结构选型要素</p>



<ol class="wp-block-list">
<li>管道口径适配两种主体结构<br>1）管段式热式流量计：适配 DN15~DN100 中小口径工艺气体管线，出厂完成标定，流场稳定，重复性较好；新建管线、允许断管安装场景优先选用；<br>2）插入式热式流量计：适配 DN80 及以上中大口径风管、烟道、燃气主管，无需整管切割，可在线开孔安装，适合老旧管路改造项目。</li>



<li>管道材质、直管段条件<br>1）金属、塑料管道均可适配插入式探头，管壁材质对测量影响较小；<br>2）管路弯头、风机、阀门密集，直管段长度不足：可选用多平均测点插入探头，或配套管道整流器优化气流分布；管路规整、直管段充足场景，标准单测点探头即可满足使用。</li>
</ol>



<p class="wp-block-paragraph">四、温度、压力工况匹配</p>



<ol class="wp-block-list">
<li>介质温度<br>1）常温工艺气体：标准型探头适配；<br>2）中高温烟气、热风管道：选用耐高温探杆与传感组件，核对探头长期耐温参数，避免高温损坏铂丝元件；<br>3）低温室外气体管线，做好管路与探头保温，防止水汽冷凝附着传感部件。</li>



<li>管路压力<br>热式流量计适配常压、低压微负压风道场景；高压密闭工艺气体管线，需选用对应耐压等级管段式本体与密封组件，匹配系统工作压力。</li>
</ol>



<p class="wp-block-paragraph">五、现场使用环境选型要素</p>



<ol class="wp-block-list">
<li>防爆环境区分<br>1）普通通风厂房、无易燃易爆介质：标准通用型主机；<br>2）燃气、化工、锂电池车间等防爆区域：选用对应防爆等级变送与探头组件。</li>



<li>户外与室内环境<br>1）室内厂房：常规防护等级主机即可；<br>2）露天烟道、室外架空管线：选用高防护等级表头，搭配防雨防晒保护箱体。</li>



<li>电磁干扰环境<br>周边存在变频器、大功率风机电机的工况，选用带双层屏蔽线缆的配套组件，降低电磁信号干扰。</li>
</ol>



<p class="wp-block-paragraph">六、供电与信号输出配置<br>1.现场具备 24V 直流供电线路：选用外供电智能远传主机；<br>2.野外无供电风道、独立监测点位：选用电池供电一体式表头；<br>3.仅现场查看流量数值：搭配就地液晶显示模块；<br>4.对接二次仪表、PLC 控制系统：支持脉冲、4-20mA 电流输出；<br>5.中控远程集中数据采集：选用带 RS485 Modbus 通讯输出型号。</p>



<p class="wp-block-paragraph">七、配套辅件匹配梳理<br>1.过滤装置：含粉尘、油雾气体配套前置过滤器，保护传感探头；<br>2.气液分离器：易凝露介质管路配套分离设备，去除液态水滴；<br>3.整流器：直管段不足管道，优化气流，减少测量波动；<br>4.安装底座：插入式配套专用球阀底座，可带压插拔维护探头，无需停机泄压。</p>



<p class="wp-block-paragraph">八、工况适配汇总<br>适配场景<br>干燥洁净单一 / 混合低压气体、车间压缩空气能耗监测、氮气 / 氩气保护气计量、污水曝气风管、锅炉热风烟道、锂电池工艺保护气、大口径通风管道、微小微量气体管线。<br>不适配场景<br>高粉尘高油雾烟气、大量液态凝液混合气体、强腐蚀工艺气体、长期极小流量低于仪表测量下限、高压密闭超量程管线。</p>
<p><a href="https://www.zhanfengdesign.com/9134/">热式气体质量流量计选型参考要素，气体介质与现场工况匹配梳理</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.zhanfengdesign.com/9134/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>影响热式气体质量流量计精度的原因分析</title>
		<link>https://www.zhanfengdesign.com/2963/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Thu, 11 Jan 2024 09:04:59 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[热式气体质量流量计技术文章]]></category>
		<category><![CDATA[流量仪表]]></category>
		<category><![CDATA[热式气体质量流量计]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>热式气体质量流量计是应用范围比较广泛的流 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/2963/">影响热式气体质量流量计精度的原因分析</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p>热式气体质量流量计是应用范围比较广泛的流量计，许多用户在选择热式气体质量流量计的时候比较关心其精度，实际应用中什么样因素以及问题影响其精度呢。<a href="https://www.zhanfengdesign.com/rsqtzlllj/">热式气体质量流量计</a>在实际应用中精度及影响精度的因素主要有以下几个方面。在正常的使用条件下,仪表测量结果的准确程度叫仪表的准确度. 习惯上称为精度。热式气体质量流量计的精度为：±1%读数 + ±0.5%满量程</p>
<p>&nbsp;</p>
<p>一：直管段的影响</p>
<p>直管段不足时，对测量精度有影响，不同的流阻影响的大小不同，提供流阻信息和直管段长度，可计算出偏差大小。</p>
<p>&nbsp;</p>
<p>二： 水、水汽</p>
<p>所测介质中含有水或水汽，如果在探头上结有水滴，将会造成测量值偏大。偏差大小是不可计算的。</p>
<p>&nbsp;</p>
<p>三： 插入深度的影响</p>
<p>在标定时，传感器的探头在管道的中心线上，如果实际安装时偏离中心线，将会造成测量值有偏差。偏差大小是不可计算的。</p>
<p>&nbsp;</p>
<p>四： 组份变化</p>
<p>当所测介质组份发生变化时，将会造成测量值有偏差。提供变化后的组份，可计算出偏差大小。</p>
<p>&nbsp;</p>
<p>五： 解决措施</p>
<p>对介质中含有水或水汽的测量，建议采用在水平管道的下半圆斜向上45 度角开孔的安装方式。</p>
<p>&nbsp;</p>
<p>总结</p>
<p>针对以上几个方面的因素，我们可以看出热式在使用过程中，工况环境对产品的影响比较大，还有就是有合理的安装方式，这样才能使得热式气体质量流量计保持其很高精度。</p>
<p><a href="https://www.zhanfengdesign.com/2963/">影响热式气体质量流量计精度的原因分析</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>热式气体质量流量计参数</title>
		<link>https://www.zhanfengdesign.com/2962/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Thu, 11 Jan 2024 09:00:41 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[热式气体质量流量计技术文章]]></category>
		<category><![CDATA[流量仪表]]></category>
		<category><![CDATA[热式气体质量流量计]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>热式气体质量流量计是利用热扩散原理测量气 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/2962/">热式气体质量流量计参数</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p>热式气体质量流量计是利用热扩散原理测量气体流量的仪表。传感器由两个基准级热电阻(RTD)组成。一个是速度传感器RH，一个是测量气体温度变化的温度传感器RMG。当这两个RTD置于被测气体中时，其中传感器RH被加热，另一个传感器RMG用于感应被测气体温度。随着气体流速的增加，气流带走更多热量，传感器RH的温度下降。</p>
<p><a href="https://www.zhanfengdesign.com/rsqtzlllj/">热式气体质量流量计</a>是基于热扩散原理而设计的，该仪表采用恒温差法对气体进行准确测量。具有体积小、数字化程度高、安装方便、测量准确等优点。</p>
<p>&nbsp;</p>
<p>热式气体质量流量计特点：</p>
<p>1.安装方便，维修简单双向检测，防振动；</p>
<p>2.多至8点流量测量；</p>
<p>3.输出模拟量的校正多点非线性曲线修正；</p>
<p>4.宽量程比100：1；</p>
<p>5.流量与温度同时检测，切换显示；</p>
<p>6.大口径小流量测量，可做泄露检测；</p>
<p>7.采用专有技术“双平衡结构”封装传感器；</p>
<p>8.专有高湿、高温算法，介质温度可达500℃；</p>
<p>9.直接质量流量检测，无需温度压力补偿。</p>
<p>&nbsp;</p>
<p>热式气体质量流量计技术参数：</p>
<p>适用介质：与不锈钢相兼容的一切气体；</p>
<p>测量范围：0.05 &#8211; 120m/s；</p>
<p>工作温度：-40℃ &#8211; 510℃；</p>
<p>环境温度：-40℃ &#8211; 85℃湿度小于90%RH；</p>
<p>压 降：</p>
<p>对于直径大于或等于3英寸的管道可以忽略不计电源要求：</p>
<p>18 &#8211; 30VDC最大600mA</p>
<p>180 &#8211; 230VAC最大2.5W</p>
<p>100VAC最大3.15W。</p>
<p>输出信号：与质量流量成比例的线形4-20mA与温度成比例的线形4-20mA；</p>
<p>精 度：1%的读数±0.5%的满量程；</p>
<p>重 复 性：±0.2%F.S；</p>
<p>耐 压：4.2MPa；</p>
<p>响应时间：≤850ms；</p>
<p>外壳材料：压铸铝，A2/A4可选；</p>
<p>探头材料：316L，钽，钛等可选；</p>
<p>球 阀：316L；</p>
<p>紧压接头：316L/304；</p>
<p>法 兰：316L/304；</p>
<p>报警输出：继电器常开触点容量220AC/3A或24VDC（只针对流量值的报警输出）、可以温度输出；</p>
<p>显 示：宽屏LCD显示，参数及变量可通过面板上按键设定（带密码保护）；</p>
<p>防护等级：IP65。</p>
<p><a href="https://www.zhanfengdesign.com/2962/">热式气体质量流量计参数</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>热式气体质量流量计适用场合</title>
		<link>https://www.zhanfengdesign.com/2945/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Fri, 15 Dec 2023 09:01:08 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[热式气体质量流量计技术文章]]></category>
		<category><![CDATA[流量仪表]]></category>
		<category><![CDATA[热式气体质量流量计]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>热式气体质量流量计是一种常用的流量测量仪 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/2945/">热式气体质量流量计适用场合</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p>热式气体质量流量计是一种常用的流量测量仪器，主要针对于液体、气体、蒸汽等介质进行测量，具有测量精确度高、灵敏性好、可靠性高等优点。<a href="https://www.zhanfengdesign.com/rsqtzlllj/">热式气体质量流量计</a>可以应用于哪些领域中呢?</p>
<p>&nbsp;</p>
<p>下面小编就来具体介绍一下，希望可以帮助到大家。</p>
<p>&nbsp;</p>
<p>热式气体质量流量计的应用场合</p>
<p>&nbsp;</p>
<p>1、公用工程&#8212;电﹑气﹑ 水处理的监控</p>
<p>管道的气体;通用系统;沼气;煤气;天然气;液化气;锅炉预热空气</p>
<p>&nbsp;</p>
<p>2、石油与天然气工业</p>
<p>能量交换;填井气回收; 燃气计量;气体质量分析;泄漏气测试;天然气测量;火炬气的监控</p>
<p>&nbsp;</p>
<p>3、电力行业</p>
<p>燃料系统中气体分配过程中的气体测量;锅炉及辅助系统中各种气体的测量;燃气炉中气体测量;氢气测量;电厂高炉的一次风、二次风的测量</p>
<p>&nbsp;</p>
<p>4、化学行业</p>
<p>烟气循环监测;采样系统中气体流量计量;引风机的气体流量计量;化肥厂氨气测量 ;电池工厂各种气体流量测量</p>
<p>&nbsp;</p>
<p>5、冶金行业</p>
<p>钢铁厂加气测量;炼铁厂高炉煤气的测量;焦化厂焦炉煤气的测量;轧钢厂加热炉燃气(高炉煤气、焦化煤气、天然气等)的测量控制;热处理淬火炉等的氢、氧、氮等气体的控制</p>
<p>&nbsp;</p>
<p>6、纸浆与造纸行业</p>
<p>废水处理系统中气体的测量;烟道流量监控;锅炉回收二次/三次空气;锅炉的燃气和空气送风测量</p>
<p>&nbsp;</p>
<p>7、食品及医药行业</p>
<p>加工操作中新鲜空气的加入;啤酒厂中的二氧化碳处理;瓶子消毒器中的热空气的流量;热氧化过程中气体流量测量;通风系统;锅炉进气﹑废气﹑过程控制</p>
<p>&nbsp;</p>
<p>8、环保</p>
<p>沼气利用过程中的气体测量;氯气处理过程中氯气气体测量;污水处理过程中曝气池的气体测量;烟筒烟道排气监测SO2和NOX的排量</p>
<p>&nbsp;</p>
<p>9、其他行业</p>
<p>工厂压缩空气测量;煤粉燃烧过程粉/气配比控制燃料;水泥工业竖式磨粉机排放热气流量控制。</p>
<p><a href="https://www.zhanfengdesign.com/2945/">热式气体质量流量计适用场合</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>热式气体质量流量计的维护</title>
		<link>https://www.zhanfengdesign.com/2944/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Fri, 15 Dec 2023 08:58:25 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[热式气体质量流量计技术文章]]></category>
		<category><![CDATA[流量仪表]]></category>
		<category><![CDATA[热式气体质量流量计]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>热式气体质量流量计在进行实际维护的过程中 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/2944/">热式气体质量流量计的维护</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p>热式气体质量流量计在进行实际维护的过程中将会有各种不同的维护工作，关于<a href="https://www.zhanfengdesign.com/rsqtzlllj/">热式气体质量流量计</a>如何来有效做好维护工作，这是大多数的人非常想了解的一件事。正确使用流量计方面用户都知道，如何做到细致入微的维护很多用户就犯难了，今天针对热式气体质量流量计的维护工作做出以下几点分析：</p>
<p>&nbsp;</p>
<p>1、定期对系统进行标校 ，抄录表头数据，以及更换参数</p>
<p>&nbsp;</p>
<p>2、对于电池的使用情况和仪表参数的准确，定期安排专人检查和检测</p>
<p>&nbsp;</p>
<p>3、定期检查零件的磨损情况，做好清洁工作，紧固松动部位，延长流量计的使用寿命</p>
<p>&nbsp;</p>
<p>4、如果流量计出现结垢现象，一定要清洗掉，保证流量计的精度！</p>
<p>&nbsp;</p>
<p>5、不定期的检查维护和铅封！</p>
<p>&nbsp;</p>
<p>在空气质量监测中，热式气体质量流量计是一种重要的设备，其选择和维护非常重要。选择型号时应考虑测量范围、测量精度、环境要求和维护要求，确保所选设备能满足实际需要。保养时要注意清洁、校准和更换零件等确保设备的稳定性和可靠性。</p>
<p><a href="https://www.zhanfengdesign.com/2944/">热式气体质量流量计的维护</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>热式气体质量流量计不适用哪些工况</title>
		<link>https://www.zhanfengdesign.com/2911/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Mon, 23 Oct 2023 09:03:47 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[热式气体质量流量计技术文章]]></category>
		<category><![CDATA[流量仪表]]></category>
		<category><![CDATA[热式气体质量流量计]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>热式气体质量流量计是一种高端的气体测量仪 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/2911/">热式气体质量流量计不适用哪些工况</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p>热式气体质量流量计是一种高端的气体测量仪表，其优点众多，量程比宽，大口径时可制成球阀插入式，便于后续的拆装一检修，供电方式多样，24v或220v均可，底面管道就地表头显示，高空管道分体表头显示，但是并不是所有场合都适用<a href="https://www.zhanfengdesign.com/rsqtzlllj/">热式气体质量流量计</a>的。</p>
<p>&nbsp;</p>
<p>第一:介质温度，热式气体质量流量计基于热扩散原理设计而成，流量计的探针是根据被测介质温度来决定探针加热温度的，一般探针加热温度比介质温度高50度。由此可以看出，流量计在正常测量时要求被测介质温度较为恒定，此时加热电流与介质流量成比例关系；</p>
<p>&nbsp;</p>
<p>第二：介质成分，热式气体质量质量计几乎可以测量所有的单一气体介质，但是在实际测量中有不少混合气体需要测量，此时选用热式气体质量流量计时，就对混合气体成分有要求。所有气体流量仪表标定时均用空来作为被测介质，单一介质时可查遍得出标准的转换系数。然而混合气体需根据现场时间被测介质成分百分比来折算转换系数，但是当测量时介质成分发生变化，则会增大流量计的测量误差；</p>
<p>&nbsp;</p>
<p>第三，压力；热式气体质量流量计不建议在高压工况环境下使用。热式测量的最重要的一点就介质的携热量，当现场的压力过高时，单位体积内介质的携热量很大，在压缩系数与反应速率的双重影响下，使得流量计的测量值将会小于实际使用时，因此建议热式气体质量流量计在4mpa以内使用。</p>
<p>&nbsp;</p>
<p>第四，高温；测量高温介质意味着传感器的耐温更高，同时测量高温介质时整机电路耗电功率增大，现阶段热式气体质量流量计可耐高温至400度，可满足绝大多数现场需求，但是与孔板等差压式流量计相比，耐高温上还有有所不如。</p>
<p><a href="https://www.zhanfengdesign.com/2911/">热式气体质量流量计不适用哪些工况</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>热式气体质量流量计的特点有哪些</title>
		<link>https://www.zhanfengdesign.com/2910/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Mon, 23 Oct 2023 08:59:59 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[热式气体质量流量计技术文章]]></category>
		<category><![CDATA[流量仪表]]></category>
		<category><![CDATA[热式气体质量流量计]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>热式气体质量流量计采用热扩散原理，热扩散 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/2910/">热式气体质量流量计的特点有哪些</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p>热式气体质量流量计采用热扩散原理，热扩散技术是一种在苛刻条件下性能优良、可靠性高的技术。<a href="https://www.zhanfengdesign.com/rsqtzlllj/">热式气体质量流量计</a>有两个温度传感器被置于介质中时，其中一个传感器被加热到环境温度以上的的温度，另一个温度传感器用于感应介质温度。介质流速增加，介质带走的热量增多，两个温度传感器的温度差将随介质的流速变化而变化，根据温度差与介质流速的比例关系，可得出流体的流量Q。热式气体质量流量计目前绝大部分用于测量气体，只有少量热式气体质量流量计用于测量微小液体流量。</p>
<p>&nbsp;</p>
<p>热式气体质量流量计的特点：</p>
<p>1、无可动部件，密封面减少，大大降低泄漏率，便于安装和日常维护;</p>
<p>2、测量范围宽，测量范围可达20:1(液体)或30:1(气体);</p>
<p>3、计量准确、精度高，法兰式可达0.2%(液体)或0.5%(气体);</p>
<p>4、灵敏度极高，能测量超小流量，其可测量低流速为0.08m/s，电磁流量计0.5m/s;</p>
<p>5、重复性好，一般为0.05~0.08%,具有可选小信号切除，非线性修正，滤波时间可选择;</p>
<p>6、压力损失小，小口径仅为标准孔板的1/2△P左右;DN100口径以上压力损失开始大幅度减少;</p>
<p>7、标定方便，除可采用标准装置检定外，还可采用干式标定方法，即采用砝码挂重法，单键操作即可完成标定;</p>
<p>8、可根据实际需要更换阻流件而改变流量范围，在线可拆装插入式结构可实现不停产，不断流维修或更换;</p>
<p>9、低功耗电池现场显示，能在线直读示值，显示屏可同时读取瞬时流量累积流量及百分比棒图，并可切换显示补偿温度及补偿压力示值;</p>
<p>10、抗干扰、抗杂质能力特强，多种输出形式，能远传各种参数，使用无需拌热。</p>
<p>11、测量气体无需温度压力补偿，可直接显示标况体积流量。</p>
<p><a href="https://www.zhanfengdesign.com/2910/">热式气体质量流量计的特点有哪些</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>热式气体质量流量计用途有哪些</title>
		<link>https://www.zhanfengdesign.com/2875/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Thu, 31 Aug 2023 10:19:11 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[热式气体质量流量计技术文章]]></category>
		<category><![CDATA[流量仪表]]></category>
		<category><![CDATA[热式气体质量流量计]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>热式气体质量流量计采用稳定性极高的传感器 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/2875/">热式气体质量流量计用途有哪些</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p>热式气体质量流量计采用稳定性极高的传感器，在线不断流装卸，维护方便。<a href="https://www.zhanfengdesign.com/rsqtzlllj/">热式气体质量流量计</a>适用行业：化学行业：烟气循环检测；采样系统中气体流量计量；引风机的气体流量计量；化肥厂氨气测量；电池工厂各种气体流量测量。食品及医药行业：加工操作中新鲜空气的加入；啤酒厂中的二氧化碳处理；瓶子消毒器中的热空气的流量；热氧化过程中气体流量测量；通风系统；锅炉进气、废弃、过程控制。石油与天然气工业：能量交换；填井气回收；燃气计量；气体质量分析；泄露气测试；天然气测量；火炬气的监控。其他行业：工厂压缩空气测量；煤粉燃烧过程粉/气配比控制燃料；水泥工业竖式磨粉机排放热气流量控制。</p>
<p>&nbsp;</p>
<p>热式气体质量流量计的适用场合：</p>
<p>1、热式气体质量流量计在公用工程&#8212;电﹑气﹑ 水处理的监控</p>
<p>管道的气体；通用系统；沼气；煤气；天然气；液化气；锅炉预热空气</p>
<p>&nbsp;</p>
<p>2、热式气体质量流量计在石油与天然气工业的应用</p>
<p>能量交换;填井气回收; 燃气计量；气体质量分析;泄漏气测试；天然气测量；火炬气的监控</p>
<p>&nbsp;</p>
<p>3、热式气体质量流量计在电力行业的应用</p>
<p>燃料系统中气体分配过程中的气体测量；锅炉及辅助系统中各种气体的测量；燃气炉中气体测量；氢气测量；电厂高炉的一次风、二次风的测量</p>
<p>&nbsp;</p>
<p>4、热式气体质量流量计在化学行业行业</p>
<p>烟气循环监测；采样系统中气体流量计量；引风机的气体流量计量；化肥厂氨气测量；电池工厂各种气体流量测量</p>
<p>&nbsp;</p>
<p>5、热式气体质量流量计在冶金行业应用</p>
<p>钢铁厂加气测量；炼铁厂高炉煤气的测量；焦化厂焦炉煤气的测量；轧钢厂加热炉燃气(高炉煤气、焦化煤气、天然气等)的测量控制；热处理淬火炉等的氢、氧、氮等气体的控制</p>
<p>&nbsp;</p>
<p>6、热式气体质量流量计在纸浆与造纸行业的应用</p>
<p>废水处理系统中气体的测量；烟道流量监控；锅炉回收二次/三次空气；锅炉的燃气和空气送风测量</p>
<p>&nbsp;</p>
<p>7、热式气体质量流量计在食品及医药行业的应用</p>
<p>加工操作中新鲜空气的加入；啤酒厂中的二氧化碳处理；瓶子消毒器中的热空气的流量；热氧化过程中气体流量测量；通风系统；锅炉进气﹑废气﹑过程控制</p>
<p>&nbsp;</p>
<p>8、热式气体质量流量计在环保行业的应用</p>
<p>沼气利用过程中的气体测量；氯气处理过程中氯气气体测量；污水处理过程中曝气池的气体测量；烟筒烟道排气监测SO2和NOX的排量</p>
<p>&nbsp;</p>
<p>9、热式气体质量流量计在其他行业的应用</p>
<p>工厂压缩空气测量；煤粉燃烧过程粉/气配比控制燃料；水泥工业竖式磨粉机排放热气流量控。</p>
<p><a href="https://www.zhanfengdesign.com/2875/">热式气体质量流量计用途有哪些</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>热式气体质量流量计具有哪些优缺点</title>
		<link>https://www.zhanfengdesign.com/2874/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Thu, 31 Aug 2023 10:18:16 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[热式气体质量流量计技术文章]]></category>
		<category><![CDATA[流量仪表]]></category>
		<category><![CDATA[热式气体质量流量计]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>热式气体质量流量计有什么优点呢？热式气体 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/2874/">热式气体质量流量计具有哪些优缺点</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p>热式气体质量流量计有什么优点呢？热式气体质量流量计又有哪些缺点和不足之处呢？</p>
<p>&nbsp;</p>
<p><a href="https://www.zhanfengdesign.com/rsqtzlllj/">热式气体质量流量计</a>有什么优势？</p>
<p>真正的质量流量计，对气体流量测量无需温度和压力补偿，测量方便、准确。可得到气体的质量流量或者标准体积流量。</p>
<p>宽量程比，可测量流速高至100Nm/s底至0.5Nm/s的气体，可以用于气体检漏。抗震性能好使用寿命长。传感器无活动部件和压力传感部件，不受震动对测量精度的影响。</p>
<p>安装维修简便。在现场条件允许的情况下，可以实现不停产安装和维护。（需要特殊定制）</p>
<p>数字化设计。整体数字化电路测量，测量准确、维修方便。采用RS-485通讯，或HART通讯，可以实现工厂自动化、集成化。</p>
<p>&nbsp;</p>
<p>热式气体质量流量计有什么缺点？</p>
<p>1、热式质量流量计响应慢。</p>
<p>2、被测量气体组分变化较大的场所，因cp值和热导率变化，测量值会有较大变化而产生误差。</p>
<p>3、对小流量而言，仪表会给被测气体带来相当热量。</p>
<p>4、对于热分布式热式气体质量流量计，被测气体若在管壁沉积垢层影响测量值，必须定期清洗;对细管型仪表更有易堵塞的缺点，一般情况下不能使用。</p>
<p>5、对脉动流在使用上将受到限制。</p>
<p>6、液体用热式质量流量计对于粘性液体在使用上亦受到限制。</p>
<p><a href="https://www.zhanfengdesign.com/2874/">热式气体质量流量计具有哪些优缺点</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>热式气体质量流量计故障处理</title>
		<link>https://www.zhanfengdesign.com/1458/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Tue, 27 Apr 2021 09:52:03 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[热式气体质量流量计技术文章]]></category>
		<category><![CDATA[流量仪表]]></category>
		<category><![CDATA[热式气体质量流量计]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>热式气体质量流量计在使用过程中会出现无显 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1458/">热式气体质量流量计故障处理</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div><a href="https://www.zhanfengdesign.com/rsqtzlllj/">热式气体质量流量计</a>在使用过程中会出现无显示、流速低、流速异常、4-20mA输出异常、报警输出异常、RS-485输出异常等故障，当遇到这些故障要如何处理呢？流量计厂家技术人员下面为大家一一介绍。</div>
<div></div>
<div>一、无显示</div>
<div>1.没有送电——打开电源</div>
<div>2.仪表内部开关电源损坏——接通220VAC，电源指示灯不亮，说明开关电源损坏</div>
<div>3.DC24V电源接反——检测电源极性</div>
<div>4.显示屏插偏了——重新插屏</div>
<div>5.显示屏损坏——检查电源指示灯，指示灯亮，说明显示屏损坏</div>
<div></div>
<div>二、流速异常，流量波动大</div>
<div>1.流速参数设置有误——检查流速参数设置</div>
<div>2.流体性质是脉动轮流——调整滤波系数</div>
<div>3.传感器脏了——清洁传感器</div>
<div>4.传感器损坏——返回供应商</div>
<div></div>
<div>三、流速低</div>
<div>1.探头方向接反——正确安装探头方向</div>
<div>2.传感器脏了——清洁传感器</div>
<div>3.传感器损坏——返回供应商</div>
<div>4.流量参数设置有误——检查参数设置</div>
<div></div>
<div>四、4-20mA输出异常</div>
<div>1.量程设置有错误——正确设置</div>
<div>2.转换器故障——返回供应商</div>
<div>3.接线未成环路——检查接线</div>
<div></div>
<div>五、RS-485输出异常</div>
<div>1.波特率和站号设置有问题——正确输入</div>
<div>2.极性接反——改变极性</div>
<div>3.连接线损坏——检查连接线路</div>
<div></div>
<div>六、报警输出异常</div>
<div>1.参数设置有误——正确设置报警参数</div>
<div>2.未配置报警输出功能——联系供应商</div>
<div>3.继电器损坏—返厂检修</div>
<p><a href="https://www.zhanfengdesign.com/1458/">热式气体质量流量计故障处理</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>热式气体质量流量计接线图</title>
		<link>https://www.zhanfengdesign.com/1457/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Tue, 27 Apr 2021 09:39:16 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[热式气体质量流量计技术文章]]></category>
		<category><![CDATA[流量仪表]]></category>
		<category><![CDATA[热式气体质量流量计]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>热式气体质量流量计接线 1 传感器接线端 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1457/">热式气体质量流量计接线图</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>
	热式气体质量流量计接线</div>
<div>
	<strong>1 传感器接线端子说明</strong></div>
<div>
	<img decoding="async" alt="" src="/uploads/allimg/210427/1-21042GJ0055S.jpg" style="width: 212px; height: 112px;" />
	 </div>
<div>
	2 输出接线端子说明及接线方法：</div>
<div>
	<strong>(1)电源的接法 </strong></div>
<div>
	a.交流电源供电的接法</div>
<div>
	<img decoding="async" alt="" src="/uploads/allimg/210427/1-21042GJ01CN.jpg" style="width: 550px; height: 191px;" /></div>
<div>
	<strong>b.直流 24V 供电的接法:</strong></div>
<div>
	<img decoding="async" alt="" src="/uploads/allimg/210427/1-21042GJ029520.jpg" style="width: 550px; height: 188px;" /></div>
<div>
	<strong>(2)四线制 4-20mA 电流输出和 HART 手操器的接法:</strong></div>
<div>
	<img decoding="async" alt="" src="/uploads/allimg/210427/1-21042GJ041N5.jpg" style="width: 550px; height: 246px;" /></div>
<div>
	<strong>(3)RS-485 通讯的接法</strong></div>
<div>
	<img decoding="async" alt="" src="/uploads/allimg/210427/1-21042GJ054537.jpg" style="width: 550px; height: 175px;" /></div>
<div>
	<strong>(4)脉冲输出的接法</strong></div>
<div>
	<img decoding="async" alt="" src="/uploads/allimg/210427/1-21042GJ10K54.jpg" style="width: 550px; height: 204px;" /></div>
<div>
	<strong>(5)报警输出的接法:</strong></div>
<div>
	<img decoding="async" alt="" src="/uploads/allimg/210427/1-21042GJ120a4.jpg" style="width: 550px; height: 195px;" /></div>
<p><a href="https://www.zhanfengdesign.com/1457/">热式气体质量流量计接线图</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>热式气体质量流量计的结构图</title>
		<link>https://www.zhanfengdesign.com/1456/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Tue, 27 Apr 2021 09:34:27 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[热式气体质量流量计技术文章]]></category>
		<category><![CDATA[流量仪表]]></category>
		<category><![CDATA[热式气体质量流量计]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>附录 1 结构尺寸图 附录 2 满管式流 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1456/">热式气体质量流量计的结构图</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>
	附录 1 结构尺寸图</div>
<div>
	<img decoding="async" alt="" src="/uploads/allimg/210427/1-21042GI44X11.jpg" style="width: 550px; height: 392px;" /></div>
<div>
	<img decoding="async" alt="" src="/uploads/allimg/210427/1-21042GI504315.jpg" style="width: 487px; height: 340px;" /></div>
<div>
	附录 2 满管式流量计数据表</div>
<div>
	管段式传感器管段尺寸表（法兰连接）</div>
<div>
	<img decoding="async" alt="" src="/uploads/allimg/210427/1-21042GI51Q95.jpg" style="width: 550px; height: 549px;" /></div>
<div>
	1. 法兰采用国标 GB/T9119-2000 标准。并依照 GB/T9119-2000 标准加工生产。</div>
<div>
	2. 对于 DN25～DN80 可以采用管螺纹连接，但要与仪表提供商达成技术协商一致后方可执行。</div>
<div>
	3. 表中只给出了最高 1.0Mpa 额定压力数据，高于额定压力的可以定做，但要与仪表提供商达成技术协商一致后方可执行。</div>
<div>
	4. 当公称通径 DN600 以上仪表有多种设计方案，在选购是客户可以与仪表提供商进行技术沟通，我们可以按照您的要求设计生产，如果客户没有任何要求我们再满足您基本要求的前提下，就按照我们设计生产。</div>
<div>
	附录 4 部分气体物理参数</div>
<div>
	<img decoding="async" alt="" src="/uploads/allimg/210427/1-21042GI5391b.jpg" style="width: 550px; height: 716px;" /></div>
<div>
	①表示 15.6℃ 压力 101.325kpa</div>
<p><a href="https://www.zhanfengdesign.com/1456/">热式气体质量流量计的结构图</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>热式气体质量流量计调试</title>
		<link>https://www.zhanfengdesign.com/1415/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Mon, 22 Mar 2021 14:11:09 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[热式气体质量流量计技术文章]]></category>
		<category><![CDATA[流量仪表]]></category>
		<category><![CDATA[热式气体质量流量计]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>热式气体质量流量计调试与运行 仪表通过按 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1415/">热式气体质量流量计调试</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div><a href="https://www.zhanfengdesign.com/rsqtzlllj/">热式气体质量流量计</a>调试与运行</div>
<div>仪表通过按键进行参数设置，一般在安装时要使用按键手动设置一些参数。仪表有三个按键，从左到右顺序为 F1、F2 和 F3 键。通常 F1 为移位键，F2 为确认和换项键，F3 为修改和返回键。如有按键特殊功能，按键功能有所不同,使用时请参看液晶屏界面下方的按键功能说明。仪表运行时，可通过 F3 键手动切换到主界面 2/主界面 3，主界面 2 显示内容除瞬时流量更改显示为工况流量外，其余与主界面 1 内容基本相同，主界面 3 同时显示工况和瞬时的流量。</div>
<div>5.1 启动</div>
<div>仪表上电时进行自检，如果自检异常，将显示自检错误界面（自检界面说明参照自检菜单），大约 1～2 秒后跳转到主界面。否则将直接跳转到主界面。主界面启动后如下图所示：</div>
<div><img decoding="async" style="width: 471px; height: 316px;" src="/uploads/allimg/210322/1-210322222T0321.jpg" alt="" /></div>
<div>标签 1：仪表运行状态实时显示，如果正常显示“OK”，故障显示“ERR”</div>
<div>标签 2：报警通道 1 标识，显示 AL1 表示通道 1 报警。</div>
<div>标签 3：报警通道 2 标识，显示 AL2 表示通道 2 报警。</div>
<div>标签 4：仪表电流输出溢出标志，如果电流输出溢出显示“mA”。</div>
<div>标签 5：为了方便显示和读取，累积流量超过 10000000 时仪表累积显示数据要乘以 1000 后才是真正累积值。</div>
<div>标签 6：仪表通讯状态信息显示，前三位表示表号;第四位表示奇偶校验位,0:无校验;1:奇校验;2:偶校验;第五位表示波特率,0:1200;1:2400;2:4800;3:9600。</div>
<div>标签 7：瞬时流量值显示，显示最大值为 9999999。</div>
<div>标签 8：累积流量显示，显示数值最大为 8 位。</div>
<div>标签 9：当前标流速显示(标米/秒)。</div>
<div>标签 10：当前测量介质温度显示(℃)。</div>
<div>5.2 主菜单</div>
<div><img decoding="async" style="width: 329px; height: 195px;" src="/uploads/allimg/210322/1-210322222U6455.jpg" alt="" /></div>
<div>在主界面下，按 F2 键，进入主菜单界面。可通过 F1 移位键选择相应的菜单项按 F2 键进入。各菜单项操作可参看以下各部分说明，简单说明如下：</div>
<div>自检：仪表运行状态检查。</div>
<div>显示：瞬时、累积、温度显示单位的更改。</div>
<div>清零：累积流量清零。</div>
<div>设置：仪表运行参数设置。</div>
<div>校准：对零点电压、电流输出、流速表和流量系数参数设置。</div>
<div>密码：修改设置、清零和校准选项的密码。</div>
<div>5.3 自检</div>
<div><img decoding="async" style="width: 326px; height: 194px;" src="/uploads/allimg/210322/1-210322222ZV10.jpg" alt="" /></div>
<div>如果仪表运行错误，可通过进入该选项，查询具体的仪表运行错误，打钩为正常，打叉为错误。另仪表启动时执行自检，如果有错误将显示此界面。在仪表运行时，也可进入该选项查询仪表运行状态。当前测量介质温度显示(℃)。</div>
<div>5.4 清零</div>
<div><img decoding="async" style="width: 326px; height: 193px;" src="/uploads/allimg/210322/1-210322222919540.jpg" alt="" /></div>
<div>流量累积值清零，为了防止非法清空流量累积值或误操作，进入清零选项须输入密码。在密码检查界面，通过移位修改键输入正确密码，按下 F2 确认键，即进入清零界面，显示数值为当前累积流量值。在清零界面，为了防止误操作，采用双手操作同时按下 F1 和 F3 键进行清零操作，清零成功屏幕显示00000000.0000，按 F2 键进入下一界面。</div>
<div><img decoding="async" style="width: 325px; height: 191px;" src="/uploads/allimg/210322/1-210322222931205.jpg" alt="" /></div>
<div>运行时间清零，运行时间以分钟为单位，记录仪表的开机运行时间，最多 8位数字（清零操作同累积流量清零）。</div>
<div>5.6 设置</div>
<div>设置选项设置仪表工作所需的一些参数，为了防止人为误操作，进入此选项需要检查密码。输入正确密码后，即进入设置界面</div>
<div><img decoding="async" style="width: 321px; height: 162px;" src="/uploads/allimg/210322/1-2103222229425U.jpg" alt="" /></div>
<div>设置界面 1：语言选择,对设置界面的显示语言进行设置，有英语和中文可选。</div>
<div><img decoding="async" style="width: 318px; height: 165px;" src="/uploads/allimg/210322/1-210322222953a4.jpg" alt="" /></div>
<div>设置界面 2：等效管道内径，设置仪表所测管道的内径，单位毫米。</div>
<div><img decoding="async" style="width: 322px; height: 188px;" src="/uploads/allimg/210322/1-210322223005124.jpg" alt="" /></div>
<div>设置界面 3：流量下限切除，当流量低于此值时，计算流量为零。</div>
<div><img decoding="async" style="width: 323px; height: 169px;" src="/uploads/allimg/210322/1-210322223016351.jpg" alt="" /></div>
<div>设置界面 4：滤波系数，当现场流量显示波动过大影响读数时，可以加大本系数，稳定读数。输入范围为 0-32，0 为无滤波。</div>
<div><img decoding="async" style="width: 323px; height: 192px;" src="/uploads/allimg/210322/1-21032222302G37.jpg" alt="" /></div>
<div>设置界面 5：介质标况密度,用于标况体积与质量的相互转换。</div>
<div><img decoding="async" style="width: 323px; height: 187px;" src="/uploads/allimg/210322/1-210322223039427.jpg" alt="" /></div>
<div>设置界面 6：介质的转换系数，可通过更改介质编号来进行转换系数的设置，转换系数当前显示为参考数值,如有修改必要可以重新输入。当更改介质编号时，其下方显示当前选择的介质，与其对应转换系数为参考值，介质编号输入范围 0-60。</div>
<div><img decoding="async" style="width: 320px; height: 186px;" src="/uploads/allimg/210322/1-210322223049593.jpg" alt="" /></div>
<div>设置界面 7：流量量程,设置仪表的最大量程，对应电流输出 20mA 时的值。</div>
<div><img decoding="async" style="width: 324px; height: 189px;" src="/uploads/allimg/210322/1-210322223100T9.jpg" alt="" /></div>
<div>设置界面 8： 485 通讯相关设置，设置通讯时表地址和通讯模式。</div>
<div><img decoding="async" style="width: 325px; height: 190px;" src="/uploads/allimg/210322/1-2103222231154R.jpg" alt="" /></div>
<div>设置界面 9： HART 通讯相关设置，设置短地址和写保护模式。</div>
<div><img decoding="async" style="width: 324px; height: 192px;" src="/uploads/allimg/210322/1-21032222312H52.jpg" alt="" /></div>
<div>设置界面 10： 脉冲输出设置，有脉冲和当量可选择；当选择脉冲时要设置频率和量程，频率最大值为 5000，当选择当量时要设置当量系数，当量输出频率最大值为 1000。</div>
<div><img decoding="async" style="width: 322px; height: 190px;" src="/uploads/allimg/210322/1-21032222313Vc.jpg" alt="" /></div>
<div>设置界面 11：报警 1 设置， 可瞬时上限，瞬时下限，温度上限，温度下限/无可选择。报警即设置报警输出的值，回差值是为了防止当前报警变量在上限报警大于到临界控制值附近时产生控制振荡，设置回差可将产生的振荡控制在充许范围内，但同是降低了控制精度。实际应用根据现场情况和经验设置此值。</div>
<div><img decoding="async" style="width: 322px; height: 189px;" src="/uploads/allimg/210322/1-21032222314W01.jpg" alt="" /></div>
<div>设置界面 12：报警 2 设置， 可瞬时上限，瞬时下限，温度上限，温度下限/无可选择。报警即设置报警输出的值，回差值是为了防止当前报警变量在上限报警大于到临界控制值附近时产生控制振荡，设置回差可将产生的振荡控制在充许范围内，但同是降低了控制精度。实际应用根据现场情况和经验设置此值。</div>
<div><img decoding="async" style="width: 323px; height: 190px;" src="/uploads/allimg/210322/1-210322223201C1.jpg" alt="" /></div>
<div>设置界面 13： 时钟设置，校准当前运行的日期和时间，此参数出厂时已校准，设置影响记录的保存和查询，在运行前务必确认是正确的当前日期，如错误将造成记录保存的混乱。</div>
<div>5.7 校准</div>
<div>校准选项设置仪表修正所需的一些参数，设置参数为工程师级参数，更改参数影响流量测量，非专业人员勿动。为了防止人为误操作，进入此选项需要检查密码，输入正确密码后，进入校准界面。</div>
<div><img decoding="async" style="width: 324px; height: 192px;" src="/uploads/allimg/210322/1-21032222321CH.jpg" alt="" /></div>
<div>校准界面 1：零点电压值，此界面实时显示流量电压值，设置时务必确认管道内没有流量，并稳定大约半分钟以上的时间。</div>
<div><img decoding="async" style="width: 325px; height: 170px;" src="/uploads/allimg/210322/1-21032222322R91.jpg" alt="" /></div>
<div>校准界面 2：测温电阻值，输入测温传感器的电阻值</div>
<div><img decoding="async" style="width: 322px; height: 191px;" src="/uploads/allimg/210322/1-210322223240317.jpg" alt="" /></div>
<div>校准界面 3：分段流速表，设置分段标定的流速和电压值， 最大分段为 40，通过流量标定装置标定后，按照从小到大的顺序（第 0 段为零点，流速固定为零）将分段电压和流速依次输入。注意：如果 40 段没有全部使用，在最后标定段的下一段中，电压设定为 2V，流速和最后标定段的流速相同。</div>
<div><img decoding="async" style="width: 323px; height: 187px;" src="/uploads/allimg/210322/1-210322223250W4.jpg" alt="" /></div>
<div>校准界面 4：分段流量二次修正， 最多分 5 段。如果 5 段没有全部使用，在最后标定段的下一段中，流量输入为量程值，系数和上一段相同。如果不进行二次修正，将第一段和每二段的流量和系数同时置为零即可。</div>
<div><img decoding="async" style="width: 322px; height: 187px;" src="/uploads/allimg/210322/1-210322223301454.jpg" alt="" /></div>
<div>校准界面 5：电流输出校准，通过输入修正参数，调节电流的输出零点，注：修改此参数将关闭电流输出，如果和仪表相关联的系统正在使用电流输出运行，请不要设置此项。</div>
<div><img decoding="async" style="width: 323px; height: 189px;" src="/uploads/allimg/210322/1-210322223312c9.jpg" alt="" /></div>
<div>校准界面 6：温度输出校准，通过输入修正参数，修正由于电路本身所产生的误差，使温度的输出精度更高。</div>
<div>5.8 密码</div>
<div>通过此选项可分别修改清零、设置、校准的密码(清零、校准和设置密码的更改操作一致，这里只介绍设置密码的更改)，进入修改密码选择界面，选择要修改的项，进入后输入旧密码，然后在新密码项输入要修改的密码，按 F2 确认键，如果旧密码输入正确则提示修改成功，在下方提示修改成功并自动跳转到主界面，否则显示修改失败同时跳转到主界面。</div>
<div><img decoding="async" style="width: 324px; height: 190px;" src="/uploads/allimg/210322/1-2103222233243F.jpg" alt="" /></div>
<div>密码修改选择界面：通过移位键选择相应模块的密码设置。</div>
<div><img decoding="async" style="width: 325px; height: 191px;" src="/uploads/allimg/210322/1-210322223334642.jpg" alt="" /></div>
<div>密码修改界面：输入相应密码，如果正确，提示密码修改成功。否则跳转至主界面。</div>
<div>5.9 显示单位</div>
<div><img decoding="async" style="width: 323px; height: 190px;" src="/uploads/allimg/210322/1-21032222334NY.jpg" alt="" /></div>
<div>瞬时单位: 瞬时或标况单位选择。</div>
<div>累积单位:累积流量单位选择。</div>
<div>温度单位: 温度单位选择。</div>
<div>显示单位选项可更改仪表运行时显示的单位，进入显示单位界面，标况流量如果选择为液体质量有 Nm3/h、Nm3/min 、L/h 、L/min、t/h、t/min 、kg/h 和kg/min 八个选项选择。选择相应的单位，按确认键后，主界面将以设置显示单位进行数值显示。</div>
<p><a href="https://www.zhanfengdesign.com/1415/">热式气体质量流量计调试</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>热式气体质量流量计使用说明书</title>
		<link>https://www.zhanfengdesign.com/1406/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Thu, 18 Mar 2021 13:39:05 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[热式气体质量流量计技术文章]]></category>
		<category><![CDATA[流量仪表]]></category>
		<category><![CDATA[热式气体质量流量计]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>1. 序言 热式气体质量流量计是利用热传 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1406/">热式气体质量流量计使用说明书</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>1. 序言</div>
<div>热式气体质量流量计是利用热传导原理测流量的仪表。该仪表采用恒温差法对气体质量流量进行准确测量。具有体积小、数字化程度高、安装方便，测量准确等优点。</div>
<div>传感器部分由两个基准级铂电阻温度传感器组成。采用桥式环路，一个传感器测量流量温度，另一个传感器维持高于流体温度的恒温差，可以在高温和高压条件下进行流量测量。</div>
<div><a href="https://www.zhanfengdesign.com/rsqtzlllj/">热式气体质量流量计</a>具有如下技术优势：</div>
<div>1.真正的质量流量计，对气体流量测量无需温度和压力补偿，测量方便、准确。可得到气体的质量流量或者标准体积流量。</div>
<div>2.宽量程比，可测量流速高至 100Nm/s 底至 0.5Nm/s 的气体，可以用于气体检漏。</div>
<div>3.抗震性能好使用寿命长。传感器无活动部件和压力传感部件，不受震动对测量精度的影响。</div>
<div>4.安装维修简便。在现场条件允许的情况下，可以实现不停产安装和维护。（请参见安全注意事项）</div>
<div>5.数字化设计。整体数字化电路测量，测量准确、维修方便。</div>
<div>6.采用 RS-485 通讯，或 HART 通讯，可以实现工厂自动化、集成化。</div>
<div></div>
<div>2. 技术参数</div>
<div><img decoding="async" style="width: 550px; height: 371px;" src="/uploads/allimg/210318/1-21031R1403W31.jpg" alt="" /></div>
<div></div>
<div>3. 安装与连接</div>
<div>3. 1 一体型仪表安装与连接外观结构图</div>
<div><img decoding="async" style="width: 179px; height: 252px;" src="/uploads/allimg/210318/1-21031R14055E0.jpg" alt="" /></div>
<div>图 1 适用管径 DN80 以上 DN500 以下精简型热式气体质量流量计</div>
<div><img decoding="async" style="width: 222px; height: 205px;" src="/uploads/allimg/210318/1-21031R14105520.jpg" alt="" /></div>
<div>图 2 适用管径 DN10 以上 DN80 以下满管型热式气体质量流量计</div>
<div><img decoding="async" style="width: 196px; height: 303px;" src="/uploads/allimg/210318/1-21031R1411N13.jpg" alt="" /></div>
<div>图 3 适用管径 DN80 以上 DN4000 以下标准型热式气体质量流量计</div>
<div>(一) 一体型插入式应插入至被测管路轴心，所以测量杆长度视测管径大小而定。订货时应说明。若不能插入至管道轴心，将有厂方提供标定系数，以完成准确测量。</div>
<div>(二)一体型满管式采用法兰连接，符合国标 GB/T9119-2000.见附录 2.</div>
<div></div>
<div>4. 接线</div>
<div>4. 1 传感器接线端子说明</div>
<div><img decoding="async" style="width: 212px; height: 112px;" src="/uploads/allimg/210318/1-21031R1412cA.jpg" alt="" /></div>
<div>4. 2 输出接线端子说明及接线方法：</div>
<div>(1)电源的接法</div>
<div>a.交流电源供电的接法</div>
<div><img decoding="async" style="width: 550px; height: 191px;" src="/uploads/allimg/210318/1-21031R141403N.jpg" alt="" /></div>
<div>b.直流 24V 供电的接法:</div>
<div><img decoding="async" style="width: 550px; height: 188px;" src="/uploads/allimg/210318/1-21031R141512L.jpg" alt="" /></div>
<div>(2)四线制 4-20mA 电流输出和 HART 手操器的接法:</div>
<div><img decoding="async" style="width: 550px; height: 246px;" src="/uploads/allimg/210318/1-21031R14202C7.jpg" alt="" /></div>
<div>(3)RS-485 通讯的接法</div>
<div><img decoding="async" style="width: 550px; height: 175px;" src="/uploads/allimg/210318/1-21031R14214607.jpg" alt="" /></div>
<div>(4)脉冲输出的接法</div>
<div><img decoding="async" style="width: 550px; height: 204px;" src="/uploads/allimg/210318/1-21031R14225509.jpg" alt="" /></div>
<div>(5)报警输出的接法:</div>
<div><img decoding="async" style="width: 550px; height: 195px;" src="/uploads/allimg/210318/1-21031R1423N10.jpg" alt="" /></div>
<div></div>
<div>现场插入式仪表安装</div>
<div>（1）安装地点的选择</div>
<div>选择水平直管段安装，安装点表前和表后的直管段要求为：安装点上游的节流元件距安装点必须大于 5 倍管道直径，安装点下游的节流元件距安装点必须大于 3 倍管道直径，有条件的情况我们建议尽量使表前表后直管段长些。</div>
<div>（2）安装底座</div>
<div><img decoding="async" style="width: 331px; height: 195px;" src="/uploads/allimg/210318/1-21031R14249347.jpg" alt="" /></div>
<div>底座根据安装方式不同，分为标准型和精简型，安装时应使底座位于管道截面方向的最顶端，并使底座通孔的轴心垂直管道轴心。理想的底座焊接位置和焊接工艺。（如下图)</div>
<div><img decoding="async" style="width: 524px; height: 295px;" src="/uploads/allimg/210318/1-21031R14301447.jpg" alt="" /></div>
<div></div>
<div>安装球阀</div>
<div>将不锈钢专用阀门与焊接管道上的底座紧固前，应在压接触面使用密封垫（介质温度在 100℃一下使用尼龙材料。100℃以上使用紫铜材质也可选用乐泰567 专用管螺纹胶进行密封）图 8 为安装完成的效果图</div>
<div><img decoding="async" style="width: 228px; height: 227px;" src="/uploads/allimg/210318/1-21031R14312544.jpg" alt="" /></div>
<div></div>
<div>打孔</div>
<div>经相关技术人员确认符合在线安装的场合，用专用的打孔器开孔，可以实现在线不停产开孔安装。停产打孔时可以采用多种方法，但要保证孔的轴心与底座的孔心同心，若不能保证同心建议可将管道上的孔大些，这样有一定间隙可以调整。</div>
<div></div>
<div>仪表的安装</div>
<div>参照附录 1 图（标准型热式气体质量流量计）</div>
<div>1) 将仪表传感器连接杆上的止退螺母松开，使传感器存储腔连接螺母能沿着传感器连接杆向传感器方向滑动，使其传感器能完全缩入传感器存储腔连接螺母中。</div>
<div>2) 将传感器存储腔连接螺母旋紧于专用球阀上（在旋入前需在他们之间加装密封垫片）</div>
<div>3) 打开专用球阀，将传感器连接杆插入管道，直至止退螺母能够与腔式连接螺母锁紧。</div>
<div>4) 转动传感器连杆，使标记箭头与介质流动方向相同，锁紧止退螺母。</div>
<div>5) 更改转换器方向，如果显示屏的方向不能满足现场显示角度的要求，可以更改显示屏的方向，显示表头可以在水平 6 个方向转动。切断电源，打开转换器前盖，拆下传感器与转换器连线，（4 组共 6 根 接线位置排列为从左到右依次为【两根红色一组】【一根红色一组】【一根黄色一组】【两根黄色一组】 ）我们在出厂是已将组别分好。松开表头法兰（旋掉 6 颗 M6 的内六角螺丝），此时可以慢慢的移动表头（千万要小心不能讲表头跌落）。当观测方便，重新固定法兰，并连接传感器与转换器连线，盖紧前盖接通电源。</div>
<div>6) 如果您是横向安装的本款仪表的显示屏可以 90°180°270°的灵活安装，满足你现场实际需要。</div>
<div>参照附录 2 图（精简型热式气体质量流量计）</div>
<div>1) 在安装精简型热式气体质量流量计前请确认管道的实际内径和壁厚。</div>
<div>2) 将热式气体质量流量计的其余部分一起装入专用球阀内，根据实际管道内径和壁厚计算出要插入的深度。这一步可以插入个大致尺寸并用手拧紧螺母。</div>
<div>3) 转动传感器连杆，使标记箭头与介质流动方向相同。</div>
<div>4) 根据现场测得的数据换算出在传感器连接杆上的相应刻度，锁紧螺母即可。</div>
<div>5) 如果您是横向安装的本款仪表的显示屏可以 90°180°270°的灵活安装，满足你现场实际需要。</div>
<div>参照附录 3 图（满管型热式气体质量流量计）</div>
<div>满管型仪表在出厂是已经把传感器正确的装配在专用的管段上，用户只需要把管道装配到现场，因此相对现场插入式的安装要简单些。首先在管路上选择合适的安装点然后按照必要配套的管段的长度切割管道、安装相应法兰和螺栓。确定流体流量要与满管型热式气体质量流量计所标的流量标识一致。并且显示屏要垂直与水平面，管道轴心要平行水平面，误差不能超过±2.5°最后用螺栓锁紧仪表。</div>
<div>各种安装后效果图</div>
<div><img decoding="async" style="width: 310px; height: 271px;" src="/uploads/allimg/210318/1-21031R14325435.jpg" alt="" /></div>
<div><img decoding="async" style="width: 306px; height: 275px;" src="/uploads/allimg/210318/1-21031R14336206.jpg" alt="" /></div>
<div></div>
<div>5.调试与运行</div>
<div>仪表通过按键进行参数设置，一般在安装时要使用按键手动设置一些参数。仪表有三个按键，从左到右顺序为 F1、F2 和 F3 键。通常 F1 为移位键，F2 为确认和换项键，F3 为修改和返回键。如有按键特殊功能，按键功能有所不同,使用时请参看液晶屏界面下方的按键功能说明。仪表运行时，可通过 F3 键手动切换到主界面 2/主界面 3，主界面 2 显示内容除瞬时流量更改显示为工况流量外，其余与主界面 1 内容基本相同，主界面 3 同时显示工况和瞬时的流量。</div>
<div>5.1 启动</div>
<div>仪表上电时进行自检，如果自检异常，将显示自检错误界面（自检界面说明参照自检菜单），大约 1～2 秒后跳转到主界面。否则将直接跳转到主界面。主界面启动后如下图所示：</div>
<div><img decoding="async" style="width: 471px; height: 316px;" src="/uploads/allimg/210318/1-21031R14350129.jpg" alt="" /></div>
<div>标签 1：仪表运行状态实时显示，如果正常显示“OK”，故障显示“ERR”</div>
<div>标签 2：报警通道 1 标识，显示 AL1 表示通道 1 报警。</div>
<div>标签 3：报警通道 2 标识，显示 AL2 表示通道 2 报警。</div>
<div>标签 4：仪表电流输出溢出标志，如果电流输出溢出显示“mA”。</div>
<div>标签 5：为了方便显示和读取，累积流量超过 10000000 时仪表累积显示数据要乘以 1000 后才是真正累积值。</div>
<div>标签 6：仪表通讯状态信息显示，前三位表示表号;第四位表示奇偶校验位,0:无校验;1:奇校验;2:偶校验;第五位表示波特率,0:1200;1:2400;2:4800;3:9600。</div>
<div>标签 7：瞬时流量值显示，显示最大值为 9999999。</div>
<div>标签 8：累积流量显示，显示数值最大为 8 位。</div>
<div>标签 9：当前标流速显示(标米/秒)。</div>
<div>标签 10：当前测量介质温度显示(℃)。</div>
<div>5.2 主菜单</div>
<div><img decoding="async" style="width: 329px; height: 195px;" src="/uploads/allimg/210318/1-21031R14401C2.jpg" alt="" /></div>
<div>在主界面下，按 F2 键，进入主菜单界面。可通过 F1 移位键选择相应的菜单项按 F2 键进入。各菜单项操作可参看以下各部分说明，简单说明如下：</div>
<div>自检：仪表运行状态检查。</div>
<div>显示：瞬时、累积、温度显示单位的更改。</div>
<div>清零：累积流量清零。</div>
<div>设置：仪表运行参数设置。</div>
<div>校准：对零点电压、电流输出、流速表和流量系数参数设置。</div>
<div>密码：修改设置、清零和校准选项的密码。</div>
<div>5.3 自检</div>
<div><img decoding="async" style="width: 326px; height: 194px;" src="/uploads/allimg/210318/1-21031R14414Z1.jpg" alt="" /></div>
<div>如果仪表运行错误，可通过进入该选项，查询具体的仪表运行错误，打钩为正常，打叉为错误。另仪表启动时执行自检，如果有错误将显示此界面。在仪表运行时，也可进入该选项查询仪表运行状态。当前测量介质温度显示(℃)。</div>
<div>5.4 清零</div>
<div><img decoding="async" style="width: 326px; height: 193px;" src="/uploads/allimg/210318/1-21031R1443RC.jpg" alt="" /></div>
<div>流量累积值清零，为了防止非法清空流量累积值或误操作，进入清零选项须输入密码。在密码检查界面，通过移位修改键输入正确密码，按下 F2 确认键，即进入清零界面，显示数值为当前累积流量值。在清零界面，为了防止误操作，采用双手操作同时按下 F1 和 F3 键进行清零操作，清零成功屏幕显示00000000.0000，按 F2 键进入下一界面。</div>
<div><img decoding="async" style="width: 325px; height: 191px;" src="/uploads/allimg/210318/1-21031R144502Y.jpg" alt="" /></div>
<div>运行时间清零，运行时间以分钟为单位，记录仪表的开机运行时间，最多 8位数字（清零操作同累积流量清零）。</div>
<div>5.6 设置</div>
<div>设置选项设置仪表工作所需的一些参数，为了防止人为误操作，进入此选项需要检查密码。输入正确密码后，即进入设置界面</div>
<div><img decoding="async" style="width: 321px; height: 162px;" src="/uploads/allimg/210318/1-21031R14500201.jpg" alt="" /></div>
<div>设置界面 1：语言选择,对设置界面的显示语言进行设置，有英语和中文可选。</div>
<div><img decoding="async" style="width: 318px; height: 165px;" src="/uploads/allimg/210318/1-21031R14512929.jpg" alt="" /></div>
<div>设置界面 2：等效管道内径，设置仪表所测管道的内径，单位毫米。</div>
<div><img decoding="async" style="width: 322px; height: 188px;" src="/uploads/allimg/210318/1-21031R1452DJ.jpg" alt="" /></div>
<div>设置界面 3：流量下限切除，当流量低于此值时，计算流量为零。</div>
<div><img decoding="async" style="width: 323px; height: 169px;" src="/uploads/allimg/210318/1-21031R1453A27.jpg" alt="" /></div>
<div>设置界面 4：滤波系数，当现场流量显示波动过大影响读数时，可以加大本系数，稳定读数。输入范围为 0-32，0 为无滤波。</div>
<div><img decoding="async" style="width: 323px; height: 192px;" src="/uploads/allimg/210318/1-21031R1454M60.jpg" alt="" /></div>
<div>设置界面 5：介质标况密度,用于标况体积与质量的相互转换。</div>
<div><img decoding="async" style="width: 323px; height: 187px;" src="/uploads/allimg/210318/1-21031R1455U32.jpg" alt="" /></div>
<div>设置界面 6：介质的转换系数，可通过更改介质编号来进行转换系数的设置，转换系数当前显示为参考数值,如有修改必要可以重新输入。当更改介质编号时，其下方显示当前选择的介质，与其对应转换系数为参考值，介质编号输入范围 0-60。</div>
<div><img decoding="async" style="width: 320px; height: 186px;" src="/uploads/allimg/210318/1-21031R14609320.jpg" alt="" /></div>
<div>设置界面 7：流量量程,设置仪表的最大量程，对应电流输出 20mA 时的值。</div>
<div><img decoding="async" style="width: 324px; height: 189px;" src="/uploads/allimg/210318/1-21031R14620S9.jpg" alt="" /></div>
<div>设置界面 8： 485 通讯相关设置，设置通讯时表地址和通讯模式。</div>
<div><img decoding="async" style="width: 325px; height: 190px;" src="/uploads/allimg/210318/1-21031R14632953.jpg" alt="" /></div>
<div>设置界面 9： HART 通讯相关设置，设置短地址和写保护模式。</div>
<div><img decoding="async" style="width: 324px; height: 192px;" src="/uploads/allimg/210318/1-21031R14643339.jpg" alt="" /></div>
<div>设置界面 10： 脉冲输出设置，有脉冲和当量可选择；当选择脉冲时要设置频率和量程，频率最大值为 5000，当选择当量时要设置当量系数，当量输出频率最大值为 1000。</div>
<div><img decoding="async" style="width: 322px; height: 190px;" src="/uploads/allimg/210318/1-21031R14A5350.jpg" alt="" /></div>
<div>设置界面 11：报警 1 设置， 可瞬时上限，瞬时下限，温度上限，温度下限/无可选择。报警即设置报警输出的值，回差值是为了防止当前报警变量在上限报警大于到临界控制值附近时产生控制振荡，设置回差可将产生的振荡控制在充许范围内，但同是降低了控制精度。实际应用根据现场情况和经验设置此值。</div>
<div><img decoding="async" style="width: 322px; height: 189px;" src="/uploads/allimg/210318/1-21031R14FC18.jpg" alt="" /></div>
<div>设置界面 12：报警 2 设置， 可瞬时上限，瞬时下限，温度上限，温度下限/无可选择。报警即设置报警输出的值，回差值是为了防止当前报警变量在上限报警大于到临界控制值附近时产生控制振荡，设置回差可将产生的振荡控制在充许范围内，但同是降低了控制精度。实际应用根据现场情况和经验设置此值。</div>
<div><img decoding="async" style="width: 323px; height: 190px;" src="/uploads/allimg/210318/1-21031R14GT26.jpg" alt="" /></div>
<div>设置界面 13： 时钟设置，校准当前运行的日期和时间，此参数出厂时已校准，设置影响记录的保存和查询，在运行前务必确认是正确的当前日期，如错误将造成记录保存的混乱。</div>
<div>5.7 校准</div>
<div>校准选项设置仪表修正所需的一些参数，设置参数为工程师级参数，更改参数影响流量测量，非专业人员勿动。为了防止人为误操作，进入此选项需要检查密码，输入正确密码后，进入校准界面。</div>
<div><img decoding="async" style="width: 324px; height: 192px;" src="/uploads/allimg/210318/1-21031R14I0249.jpg" alt="" /></div>
<div>校准界面 1：零点电压值，此界面实时显示流量电压值，设置时务必确认管道内没有流量，并稳定大约半分钟以上的时间。</div>
<div><img decoding="async" style="width: 325px; height: 170px;" src="/uploads/allimg/210318/1-21031R14J1S8.jpg" alt="" /></div>
<div>校准界面 2：测温电阻值，输入测温传感器的电阻值</div>
<div><img decoding="async" style="width: 322px; height: 191px;" src="/uploads/allimg/210318/1-21031R14K2a6.jpg" alt="" /></div>
<div>校准界面 3：分段流速表，设置分段标定的流速和电压值， 最大分段为 40，通过流量标定装置标定后，按照从小到大的顺序（第 0 段为零点，流速固定为零）将分段电压和流速依次输入。注意：如果 40 段没有全部使用，在最后标定段的下一段中，电压设定为 2V，流速和最后标定段的流速相同。</div>
<div><img decoding="async" style="width: 323px; height: 187px;" src="/uploads/allimg/210318/1-21031R14P2U4.jpg" alt="" /></div>
<div>校准界面 4：分段流量二次修正， 最多分 5 段。如果 5 段没有全部使用，在最后标定段的下一段中，流量输入为量程值，系数和上一段相同。如果不进行二次修正，将第一段和每二段的流量和系数同时置为零即可。</div>
<div><img decoding="async" style="width: 322px; height: 187px;" src="/uploads/allimg/210318/1-21031R14Q2G1.jpg" alt="" /></div>
<div>校准界面 5：电流输出校准，通过输入修正参数，调节电流的输出零点，注：修改此参数将关闭电流输出，如果和仪表相关联的系统正在使用电流输出运行，请不要设置此项。</div>
<div><img decoding="async" style="width: 323px; height: 189px;" src="/uploads/allimg/210318/1-21031R14R4618.jpg" alt="" /></div>
<div>校准界面 6：温度输出校准，通过输入修正参数，修正由于电路本身所产生的误差，使温度的输出精度更高。</div>
<div>5.8 密码</div>
<div>通过此选项可分别修改清零、设置、校准的密码(清零、校准和设置密码的更改操作一致，这里只介绍设置密码的更改)，进入修改密码选择界面，选择要修改的项，进入后输入旧密码，然后在新密码项输入要修改的密码，按 F2 确认键，如果旧密码输入正确则提示修改成功，在下方提示修改成功并自动跳转到主界面，否则显示修改失败同时跳转到主界面。</div>
<div><img decoding="async" style="width: 324px; height: 190px;" src="/uploads/allimg/210318/1-21031R14S9102.jpg" alt="" /></div>
<div>密码修改选择界面：通过移位键选择相应模块的密码设置。</div>
<div><img decoding="async" style="width: 325px; height: 191px;" src="/uploads/allimg/210318/1-21031R14U1210.jpg" alt="" /></div>
<div>密码修改界面：输入相应密码，如果正确，提示密码修改成功。否则跳转至主界面。</div>
<div>5.9 显示单位</div>
<div><img decoding="async" style="width: 323px; height: 190px;" src="/uploads/allimg/210318/1-21031R14Z3309.jpg" alt="" /></div>
<div>瞬时单位: 瞬时或标况单位选择。</div>
<div>累积单位:累积流量单位选择。</div>
<div>温度单位: 温度单位选择。</div>
<div>显示单位选项可更改仪表运行时显示的单位，进入显示单位界面，标况流量如果选择为液体质量有 Nm3/h、Nm3/min 、L/h 、L/min、t/h、t/min 、kg/h 和kg/min 八个选项选择。选择相应的单位，按确认键后，主界面将以设置显示单位进行数值显示。</div>
<div></div>
<div>故障排除</div>
<div><img decoding="async" style="width: 550px; height: 268px;" src="/uploads/allimg/210318/1-21031R14915503.jpg" alt="" /></div>
<div></div>
<div>附录 1 结构尺寸图</div>
<div><img decoding="async" style="width: 550px; height: 392px;" src="/uploads/allimg/210318/1-21031R14934238.jpg" alt="" /></div>
<div><img decoding="async" style="width: 487px; height: 340px;" src="/uploads/allimg/210318/1-21031R14945326.jpg" alt="" /></div>
<div>附录 2 满管式流量计数据表</div>
<div>管段式传感器管段尺寸表（法兰连接）</div>
<div><img decoding="async" style="width: 550px; height: 549px;" src="/uploads/allimg/210318/1-21031R1495H41.jpg" alt="" /></div>
<div>1. 法兰采用国标 GB/T9119-2000 标准。并依照 GB/T9119-2000 标准加工生产。</div>
<div>2. 对于 DN25～DN80 可以采用管螺纹连接，但要与仪表提供商达成技术协商一致后方可执行。</div>
<div>3. 表中只给出了最高 1.0Mpa 额定压力数据，高于额定压力的可以定做，但要与仪表提供商达成技术协商一致后方可执行。</div>
<div>4. 当公称通径 DN600 以上仪表有多种设计方案，在选购是客户可以与仪表提供商进行技术沟通，我们可以按照您的要求设计生产，如果客户没有任何要求我们再满足您基本要求的前提下，就按照我们设计生产。</div>
<div>附录 4 部分气体物理参数</div>
<div><img decoding="async" style="width: 550px; height: 716px;" src="/uploads/allimg/210318/1-21031R15024P3.jpg" alt="" /></div>
<div>①表示 15.6℃ 压力 101.325kpa</div>
<p><a href="https://www.zhanfengdesign.com/1406/">热式气体质量流量计使用说明书</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>热式气体质量流量计选型指南</title>
		<link>https://www.zhanfengdesign.com/1401/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Mon, 15 Mar 2021 14:59:12 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[热式气体质量流量计技术文章]]></category>
		<category><![CDATA[流量仪表]]></category>
		<category><![CDATA[热式气体质量流量计]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>热式气体质量流量计基于热扩散原理，采用恒 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1401/">热式气体质量流量计选型指南</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>热式气体质量流量计基于热扩散原理，采用恒温差法设计而成，是一款气体计量的专业计量仪表。其拥有高精度、宽量程比、压损小、无需温压补偿可直接计量气体标况体积流量等众多其他流量计所不具有的特点，已被广泛使用于各行各业。</div>
<div></div>
<div><strong>热式气体质量流量计在选型时需要注意以下几点</strong>：</div>
<div><a href="https://www.zhanfengdesign.com/rsqtzlllj/">热式气体质量流量计</a>恒温差计量中心点就是保证两探头之间温度恒定，介质的携热量（流速）与发热所需的供电电流成正比关系，那么介质温度与介质比热为重点参数，流量计转换器中储存有六十余种常规气体比热转换系数，该系数的设定是基体单一洁净气体。但是在现场实际测量中，介质纯度并没那么高，虽然流量计设计精度没有下滑，但是测量值与实际值有可能存在一定量偏差，这也是为什么热式气体质量流量计适合测量干燥的气体；介质温度又是热式气体质量流量计一大难点，工作时，需要将发热探头加热到比介质温度高50度状态。如果在计量时介质本身的温度变化频率过高，即加热所需的供电电流忽大忽小，致使表头显示流量波动大，其测量精度会直线下滑，不利于检测，若介质本身温度较高时，则探头所需加热温度更高，流量计设计功率小于18W，当加热温度过高时，发热所需供电电流过大（供电电流不够）则会产生多种异常情况乱，如表头流量从小到大往复循环性变化，因此热式气体质量流量计多用于测量介质温度变化频率不高且温度不超过400度的气体。</div>
<div></div>
<div>热式气体质量流量计是一种高端的气体测量仪表，其优势众多，量程比宽，大口径时可选择插入式连接方式，便于后续的拆装与检修，供电方式多样，24V或220V均可，地面管道就地表头显示，高空管道分体表头显示，但是并不是所有场合都适用热式气体质量流量计。</div>
<div></div>
<div>第一：介质温度。热式气体质量流量计基于热扩散原理设计而成，流量计的探针是根据被测介质温度来决定探针加热温度的，一般探针加热温度比介质温度高50度。由此可以看出，流量计在正常测量时要求被测介质温度较为恒定，此时加热电流与介质流量成比例关系；</div>
<div></div>
<div>第二：介质成分。热式气体质量流量计几乎可测量所有单一气体介质（乙炔除外），但是在实际测量中有不少混合气体需要测量，此时选用热式气体质量流量计时，就对混合气体万分有要求。所有气体流量仪表标定时均用空气来作为被测介质，单一介质时可查得出标准的转换系数。然而混合气体需要根据现场时间被测介质成分百分比来折算转换系数，但是当测量时介质成分发生变化，则会增大流量计测量误差；</div>
<div></div>
<div>第三：压力。热式气体质量流量计不建议在高压工况环境下使用。热式测量的重要的一点就是介质的携热量，当现场的压力过高时，单位体积内介质的携热量很大，在压缩系统与反应速率的双重影响下，使得流量计的测量值将会小于实际使用时，因此建议热式气体质量流量计在4.0Mpa以内使用。</div>
<div></div>
<div>第四：高温。测量高温介质意味着传感器的耐温更高，同时测量高温介质时整机电路耗电功率增大，现阶段热式气体质量流量计可耐高温至400度，可满足绝大多数现场要求。</div>
<p><a href="https://www.zhanfengdesign.com/1401/">热式气体质量流量计选型指南</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>热式气体质量流量计安装要求</title>
		<link>https://www.zhanfengdesign.com/1400/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Mon, 15 Mar 2021 14:48:28 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[热式气体质量流量计技术文章]]></category>
		<category><![CDATA[流量仪表]]></category>
		<category><![CDATA[热式气体质量流量计]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>热式气体质量流量计安装与连接 1 一体型 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1400/">热式气体质量流量计安装要求</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>
<div>
<div>热式气体质量流量计安装与连接</div>
<div>1 一体型仪表安装与连接外观结构图</div>
<div><img decoding="async" style="width: 179px; height: 252px;" src="/uploads/allimg/210315/1-21031522504Aa.jpg" alt="" /></div>
<div>图 1 适用管径 DN80 以上 DN500 以下精简型<a href="https://www.zhanfengdesign.com/rsqtzlllj/">热式气体质量流量计</a></div>
<div><img decoding="async" style="width: 222px; height: 205px;" src="/uploads/allimg/210315/1-210315225059561.jpg" alt="" /></div>
<div>图 2 适用管径 DN10 以上 DN80 以下满管型热式气体质量流量计</div>
<div><img decoding="async" style="width: 196px; height: 303px;" src="/uploads/allimg/210315/1-210315225114424.jpg" alt="" /></div>
<div>图 3 适用管径 DN80 以上 DN4000 以下标准型热式气体质量流量计</div>
<div>(一) 一体型插入式应插入至被测管路轴心，所以测量杆长度视测管径大小而定。订货时应说明。若不能插入至管道轴心，将有厂方提供标定系数，以完成准确测量。</div>
<div>(二)一体型满管式采用法兰连接，符合国标 GB/T9119-2000.见附录 2.</div>
<p>现场插入式仪表安装</p>
</div>
<div>（1）安装地点的选择</div>
<div>选择水平直管段安装，安装点表前和表后的直管段要求为：安装点上游的节流元件距安装点必须大于 5 倍管道直径，安装点下游的节流元件距安装点必须大于 3 倍管道直径，有条件的情况我们建议尽量使表前表后直管段长些。</div>
<div>（2）安装底座</div>
<div><img decoding="async" style="width: 331px; height: 195px;" src="/uploads/allimg/210315/1-21031522512O02.jpg" alt="" /></div>
<div>底座根据安装方式不同，分为标准型和精简型，安装时应使底座位于管道截面方向的最顶端，并使底座通孔的轴心垂直管道轴心。理想的底座焊接位置和焊接工艺。（如下图)</div>
<div><img decoding="async" style="width: 524px; height: 295px;" src="/uploads/allimg/210315/1-210315225141458.jpg" alt="" /></div>
<div></div>
<div>安装球阀</div>
<div>将不锈钢专用阀门与焊接管道上的底座紧固前，应在压接触面使用密封垫（介质温度在 100℃一下使用尼龙材料。100℃以上使用紫铜材质也可选用乐泰567 专用管螺纹胶进行密封）图 8 为安装完成的效果图</div>
<div><img decoding="async" style="width: 228px; height: 227px;" src="/uploads/allimg/210315/1-2103152251562X.jpg" alt="" /></div>
<div></div>
<div>打孔</div>
<div>经相关技术人员确认符合在线安装的场合，用专用的打孔器开孔，可以实现在线不停产开孔安装。停产打孔时可以采用多种方法，但要保证孔的轴心与底座的孔心同心，若不能保证同心建议可将管道上的孔大些，这样有一定间隙可以调整。</div>
<div></div>
<div>仪表的安装</div>
<div>参照附录 1 图（标准型热式气体质量流量计）</div>
<div>1) 将仪表传感器连接杆上的止退螺母松开，使传感器存储腔连接螺母能沿着传感器连接杆向传感器方向滑动，使其传感器能完全缩入传感器存储腔连接螺母中。</div>
<div>2) 将传感器存储腔连接螺母旋紧于专用球阀上（在旋入前需在他们之间加装密封垫片）</div>
<div>3) 打开专用球阀，将传感器连接杆插入管道，直至止退螺母能够与腔式连接螺母锁紧。</div>
<div>4) 转动传感器连杆，使标记箭头与介质流动方向相同，锁紧止退螺母。</div>
<div>5) 更改转换器方向，如果显示屏的方向不能满足现场显示角度的要求，可以更改显示屏的方向，显示表头可以在水平 6 个方向转动。切断电源，打开转换器前盖，拆下传感器与转换器连线，（4 组共 6 根 接线位置排列为从左到右依次为【两根红色一组】【一根红色一组】【一根黄色一组】【两根黄色一组】 ）我们在出厂是已将组别分好。松开表头法兰（旋掉 6 颗 M6 的内六角螺丝），此时可以慢慢的移动表头（千万要小心不能讲表头跌落）。当观测方便，重新固定法兰，并连接传感器与转换器连线，盖紧前盖接通电源。</div>
<div>6) 如果您是横向安装的本款仪表的显示屏可以 90°180°270°的灵活安装，满足你现场实际需要。</div>
<div>参照附录 2 图（精简型热式气体质量流量计）</div>
<div>1) 在安装精简型热式气体质量流量计前请确认管道的实际内径和壁厚。</div>
<div>2) 将热式气体质量流量计的其余部分一起装入专用球阀内，根据实际管道内径和壁厚计算出要插入的深度。这一步可以插入个大致尺寸并用手拧紧螺母。</div>
<div>3) 转动传感器连杆，使标记箭头与介质流动方向相同。</div>
<div>4) 根据现场测得的数据换算出在传感器连接杆上的相应刻度，锁紧螺母即可。</div>
<div>5) 如果您是横向安装的本款仪表的显示屏可以 90°180°270°的灵活安装，满足你现场实际需要。</div>
<div>参照附录 3 图（满管型热式气体质量流量计）</div>
<div>满管型仪表在出厂是已经把传感器正确的装配在专用的管段上，用户只需要把管道装配到现场，因此相对现场插入式的安装要简单些。首先在管路上选择合适的安装点然后按照必要配套的管段的长度切割管道、安装相应法兰和螺栓。确定流体流量要与满管型热式气体质量流量计所标的流量标识一致。并且显示屏要垂直与水平面，管道轴心要平行水平面，误差不能超过±2.5°最后用螺栓锁紧仪表。</div>
<div>各种安装后效果图</div>
<div><img decoding="async" style="width: 310px; height: 271px;" src="/uploads/allimg/210315/1-210315225216164.jpg" alt="" /></div>
<div><img decoding="async" style="width: 306px; height: 275px;" src="/uploads/allimg/210315/1-21031522522Ya.jpg" alt="" /></div>
</div>
<p>&nbsp;</p>
<p><a href="https://www.zhanfengdesign.com/1400/">热式气体质量流量计安装要求</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>热式气体质量流量计工作原理</title>
		<link>https://www.zhanfengdesign.com/1399/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Mon, 15 Mar 2021 12:51:44 +0000</pubDate>
				<category><![CDATA[技术文章]]></category>
		<category><![CDATA[热式气体质量流量计技术文章]]></category>
		<category><![CDATA[流量仪表]]></category>
		<category><![CDATA[热式气体质量流量计]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>热式气体质量流量计是一种可以直接测量气体 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1399/">热式气体质量流量计工作原理</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>热式气体质量流量计是一种可以直接测量气体质量流量的流量计，其具有高重复性、高可靠性、高稳定性和高精度，在测量现场灵敏度高，尤其适用于大管径、低流速的测量。由于<a href="https://www.zhanfengdesign.com/rsqtzlllj/">热式气体质量流量计</a>具有压损非常小、机械结构多样、安装灵活、使用方便诸多优点，被广泛应用于现场气体的流量测量。依据《JJG1132-2017 热式气体质量流量计》检定规程，对首次检定、后续检定和使用中检定做了明确的技术要求。</div>
<div></div>
<div>热式气体质量流量计探头有两个传感器，其中一个温度传感器测量管道内气体介质的温度，另一个为介质速度传感器，通过电加热作用将速度传感器的温度加热至高于温度传感器测量得到的温度，并且保持两个传感器温差的恒定。当气体介质流动带走速度传感器上的热量时，表头上的电桥电路为保持两个传感器的温差恒定，速度传感器需要额外进行电补偿加热，这个补偿的加热功率大小和气体介质的质量流量成正比。在实际应用中，测温传感器通常应用Pt1000或者Pt300，测速传感器一般使用Pt20。由于在 t℃时，两种传感器的电阻变化幅度并不相同，这样就造成电桥的不平衡，导致电桥连接比较器输入端的电压不同，从而触发新的加热动作。</div>
<div></div>
<div>其中，qm热式气体质量流量计瞬时流量值，kg/s；K是流量计出厂标定的修正系数值；?P 热式流量计电桥加热功率，kJ/s；Cp测量气体介质的定压比热容，kJ/(kg.℃)；?t 热式流量计两个传感器的温差值，℃；qVN是气体介质的标况体积流量，Nm3/h；ρN是气体介质的标况密度值，kg/m3。</div>
<div><img decoding="async" style="width: 500px; height: 171px;" src="/uploads/allimg/210315/1-210315205333M3.jpg" alt="" /></div>
<div>由式（1）、式（2）可见，对于不同管径下的气体测量，确定气体介质的前提下，通过标定修正系数K值就能实现现场瞬时流量和累积流量的计量。</div>
<div></div>
<div>热式气体质量流量计应用两个热电阻传感器（分别测流速和测工况温度），并通过电桥电路调整两个传感器至恒温差效果；通过标定不同流速下电桥电路的加热功率，实现热式气体瞬时流量的准确计量；通过采用电路仿真的方法对电桥电路的复杂工作过程进行了测试，测温传感器在不同的工况温度下，仿真不同气体流速下测速探头的实时温度值，验证了仪表标定可行性。热式气体质量流量计是具有较高的灵敏度和重复性的工业计量仪表，尤其适用在大管径、低流速的工业场合。</div>
<p><a href="https://www.zhanfengdesign.com/1399/">热式气体质量流量计工作原理</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>