<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>孔板流量计技术文章 - 金湖凯铭仪表</title>
	<atom:link href="https://www.zhanfengdesign.com/category/article/llyb-article/kbllj-article/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.zhanfengdesign.com/category/article/llyb-article/kbllj-article/</link>
	<description>流量&#124;液位&#124;温度&#124;压力</description>
	<lastBuildDate>Mon, 12 Oct 2026 08:42:50 +0000</lastBuildDate>
	<language>zh-Hans</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://www.zhanfengdesign.com/wp-content/uploads/2026/05/elementor/thumbs/微信图片_20250805143107_120_3-rmwn996852eavbnmbpepzofwfik8mes0k2lm3lqvvs.png</url>
	<title>孔板流量计技术文章 - 金湖凯铭仪表</title>
	<link>https://www.zhanfengdesign.com/category/article/llyb-article/kbllj-article/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>dn350 孔板流量计怎么选</title>
		<link>https://www.zhanfengdesign.com/9895/</link>
					<comments>https://www.zhanfengdesign.com/9895/#respond</comments>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Mon, 12 Oct 2026 08:42:07 +0000</pubDate>
				<category><![CDATA[孔板流量计技术文章]]></category>
		<category><![CDATA[技术文章]]></category>
		<category><![CDATA[流量仪表技术文章]]></category>
		<category><![CDATA[孔板流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false">https://www.zhanfengdesign.com/?p=9895</guid>

					<description><![CDATA[<p>一、引言在大型管网、蒸汽系统、化工装置的 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/9895/">dn350 孔板流量计怎么选</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph"><strong>一、引言</strong><br>在大型管网、蒸汽系统、化工装置的气体与蒸汽计量中，孔板流量计凭借结构简单、可靠性高、适用范围广、无可动部件的优势得到广泛应用。它基于节流原理，通过孔板节流形成的差压信号换算流量，长期运行稳定。其中 <a href="https://www.zhanfengdesign.com/kbllj/">dn350 孔板流量计</a>作为公称通径 350mm 的大口径仪表，常见于主干管道、锅炉蒸汽总管、大口径气体输送等场景。大口径流量计选型涉及的参数更多，差压、口径、材质、安装条件等因素相互影响，选型不当会造成计量偏差或压损超标。本文围绕 dn350 孔板流量计的选型方法，从工作原理、介质工况、口径核算、差压选择、材质与安装条件等角度展开讲解，为工程选型提供参考。</p>



<p class="wp-block-paragraph"><strong>二、明确测量原理与适用范围</strong><br>dn350 孔板流量计通过孔板节流产生差压，依据差压与流量的平方关系换算流量。它适合测量洁净或中等洁净的气体、蒸汽、液体，结构简单、无可动部件、长期稳定性好。选型前应确认介质特性与计量精度需求是否匹配：若介质含杂质、易结垢，孔板会结垢磨损影响精度；若对计量精度要求很高，需结合开孔直径、流出系数仔细核算。大口径管道流速较低，孔板差压较小，需选择灵敏度足够的差压变送器。</p>



<p class="wp-block-paragraph"><strong>三、收集工况参数与介质特性</strong><br><strong>3.1 介质种类与状态</strong><br>明确介质为气体、蒸汽还是液体，确认介质温度、压力、密度及是否含杂质、易结垢。蒸汽介质需区分饱和蒸汽与过热蒸汽，按对应物性参数核算。不同介质密度差异直接影响差压与流量换算，选型需准确掌握介质参数。</p>



<p class="wp-block-paragraph"><strong>3.2 流量范围</strong><br>收集最大瞬时流量、最小流量与常用流量，明确计量单位。日常稳定流量宜落在仪表量程的合适区间，最小流量应高于差压变送器测量下限，最大持续流量低于测量上限，保障计量精度与差压信号稳定。</p>



<p class="wp-block-paragraph"><strong>四、口径与差压选择</strong><br><strong>4.1 口径匹配</strong><br>dn350 孔板流量计适用于公称通径 350mm 管道，选型需确认管道实际内径、法兰标准与仪表匹配，保证孔板口径与管道同心、安装规范。核算管道流速，避免流速过低导致差压过小、测量灵敏度不足，流速过高导致压损增大。</p>



<p class="wp-block-paragraph"><strong>4.2 差压量程选择</strong><br>差压量程是 dn350 孔板流量计选型关键。差压选大则灵敏度高、可测小流量，但压损增大；差压选小则压损小、但小流量测量能力下降。应结合介质允许压损、最小流量需求综合权衡，合理选择差压变送器量程与孔板开孔比，保证全量程计量精度。</p>



<p class="wp-block-paragraph"><strong>五、材质与结构选型</strong><br><strong>5.1 孔板与管道材质</strong><br>依据介质温度、压力、腐蚀性选择孔板与法兰材质。高温蒸汽工况选用耐高温材质；腐蚀性介质选用耐蚀材质。dn350 孔板流量计口径大，材质与结构成本相对较高，需结合介质特性合理选配，兼顾性能与投资。</p>



<p class="wp-block-paragraph"><strong>5.2 安装与取压结构</strong><br>确认孔板流量计取压方式，常见角接取压、法兰取压等，按现场工况与精度要求选择。大口径仪表安装需保证前后直管段，上游留足直管段并加装整流器以减少流场畸变，取压管路、差压变送器布置合理，便于维护。</p>



<p class="wp-block-paragraph"><strong>六、配套仪表与信号输出</strong><br>dn350 孔板流量计需配套差压变送器、温压传感器及积算单元，将差压信号换算为标况流量。结合自控系统要求确认输出方式，常见 4-20mA 模拟量及 RS485、Modbus 数字通讯。贸易计量场景选配高精度变送器与积算功能，保障结算数据可靠。</p>



<p class="wp-block-paragraph"><strong>七、防爆、防护与检定要求</strong><br>易燃易爆气体计量场景，核对仪表及配套变送器防爆等级与现场危险区域匹配。户外安装选用适当防护等级，保障冬季、恶劣天气下电气性能。用于贸易计量的 dn350 孔板流量计需依法周期检定，核查孔板几何尺寸与差压变送器精度，保障计量可溯源。</p>



<p class="wp-block-paragraph"><strong>八、总结</strong><br>dn350 孔板流量计选型需综合介质工况、流量范围、口径匹配、差压选择、材质结构、配套仪表与检定要求系统评估。核心是准确掌握介质参数、合理核算流量与差压、正确选配孔板与变送器材质、保证安装直管段与取压结构。完整收集现场工况参数核算，规范安装、依法检定，方能充分发挥 dn350 孔板流量计计量性能，保障大口径管道计量准确可靠。</p>
<p><a href="https://www.zhanfengdesign.com/9895/">dn350 孔板流量计怎么选</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.zhanfengdesign.com/9895/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>大口径循环水管道法兰取压孔板流量计参数选用技巧</title>
		<link>https://www.zhanfengdesign.com/9527/</link>
					<comments>https://www.zhanfengdesign.com/9527/#respond</comments>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Wed, 22 Jul 2026 08:59:46 +0000</pubDate>
				<category><![CDATA[孔板流量计技术文章]]></category>
		<category><![CDATA[技术文章]]></category>
		<category><![CDATA[孔板流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false">https://www.zhanfengdesign.com/?p=9527</guid>

					<description><![CDATA[<p>工业厂区大口径循环水管道具有管径大、流量 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/9527/">大口径循环水管道法兰取压孔板流量计参数选用技巧</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">工业厂区大口径循环水管道具有管径大、流量区间宽、管路压力平稳、介质含少量泥沙水垢等特点，是厂区能耗统计、管网工况调控的核心监测点位。法兰取压结构适配大管径安装场景，参数合理选配可有效规避计量偏差，保障<a href="https://www.zhanfengdesign.com/kbllj/">孔板流量计</a>稳定完成循环水流量监测工作。</p>



<p class="wp-block-paragraph">一、公称通径与匹配参数选用技巧<br>大口径循环水管路选型需严格遵循管道原生通径，严禁随意缩径、变径选配设备，避免人为造成管路流场紊乱、压损增大。选型时精准核对管道外径、壁厚、公称压力参数，保证仪表法兰与管道完全适配。同时结合循环水运行特性匹配节流孔径比例，合理控制β值，兼顾计量灵敏度与管路流通效率，避免孔径过小导致通水阻力增大、管网回水不畅，杜绝孔径过大引发差压信号微弱、计量精度不足的问题。</p>



<p class="wp-block-paragraph">二、材质与耐磨防腐参数选用规范<br>循环水介质常含有泥沙、铁锈杂质，长期冲刷会磨损节流部件，部分循环水存在轻微水质腐蚀问题。节流板优先选用不锈钢材质，具备良好的耐磨、防锈、抗结垢性能，可耐受长期水流冲刷，维持节流尺寸稳定。法兰及腔体结构选用适配碳钢或不锈钢材质，适配室外管网、泵房潮湿环境，防止壳体锈蚀破损。相较于精密节流设备，该材质配置适配循环水粗放式运行工况，有效延长设备使用寿命。</p>



<p class="wp-block-paragraph">三、压力与温度参数适配要点<br>厂区循环水多为常温常压工况，整体运行参数稳定，但水泵启停、管网调阀会产生瞬时压力波动。选型时设备公称压力需高于管道常规工作压力，预留充足压力安全余量，耐受瞬时冲击压力，防止法兰密封渗漏、部件形变。常温循环水无需特殊耐高温配置，选用常规密封材质即可满足长期运行需求，无需额外加装高温防护配件，降低设备配套成本。</p>



<p class="wp-block-paragraph">四、法兰取压结构参数选用技巧<br>大口径管道优先选用法兰取压结构，取压点位标准化、安装便捷、后期维护简单，适配大管径不便改造的特点。取压口规格需匹配大流量工况参数，选用标准通径取压孔，避免孔径过小被水垢、杂质堵塞。取压位置严格按照规范设置，水平管道优先选取管道上部侧取压方式，规避管底泥沙沉积封堵取压口、管顶积气干扰信号的问题，保障差压信号采集连续稳定。</p>



<p class="wp-block-paragraph">五、量程与配套参数匹配方法<br>循环水管道流量昼夜、峰谷负荷差异较大，选型需结合最大通水流量、最低待机流量，搭配宽量程差压变送器，消除低流量计量盲区，保证全工况计量精准。无需复杂温压补偿配置，适配常温液态水不可压缩特性，简化配套系统。同时匹配标准三阀组组件，方便后期仪表校准、管路排污，适配大口径管道不停产运维需求。</p>



<p class="wp-block-paragraph">六、安装适配参数选用要求<br>大口径管路流场易紊乱，选型需确认设备适配标准直管段参数，结合现场弯头、阀门、变径等管件布局，预留规范的上下游直管段长度，减少流场干扰。优先选用一体式法兰结构，整体密封性好、安装牢固，适配大管径管路自重载荷，避免长期运行出现法兰松动、渗漏问题。设备防护参数适配泵房、户外管网环境，具备防尘防水性能，耐受复杂现场环境。</p>



<p class="wp-block-paragraph">选用总结<br>大口径循环水管道选配核心为匹配通径参数、优化节流比例、适配耐磨材质、规范取压结构，贴合循环水稳定工况与粗放运维特点。科学选配参数可大幅降低堵塞、磨损、计量漂移等故障，保障孔板流量计长期高效、稳定完成厂区循环水能耗统计与管网监测工作。</p>
<p><a href="https://www.zhanfengdesign.com/9527/">大口径循环水管道法兰取压孔板流量计参数选用技巧</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.zhanfengdesign.com/9527/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>防爆一体化孔板流量计煤气管道选配规范</title>
		<link>https://www.zhanfengdesign.com/9383/</link>
					<comments>https://www.zhanfengdesign.com/9383/#respond</comments>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Sun, 12 Jul 2026 03:37:00 +0000</pubDate>
				<category><![CDATA[孔板流量计技术文章]]></category>
		<category><![CDATA[技术文章]]></category>
		<category><![CDATA[孔板流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false">https://www.zhanfengdesign.com/?p=9383</guid>

					<description><![CDATA[<p>焦化、钢厂、陶瓷厂煤气管道介质含粉尘、水 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/9383/">防爆一体化孔板流量计煤气管道选配规范</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">焦化、钢厂、陶瓷厂煤气管道介质含粉尘、水汽、焦油，且一氧化碳、高炉煤气、转炉煤气均属于易燃易爆有毒介质，传统分体式节流装置引压管易积油堵塞、布线繁琐，维护工作量大，难以实现场站远程监控。集成节流件、差压变送、防爆壳体的一体式计量设备简化管路配套，<a href="https://www.zhanfengdesign.com/kbllj/">防爆一体化孔板流量计</a>集成温压补偿模块，可直接输出标况流量，是工业煤气管道能耗与环保监测主流仪表。</p>



<p class="wp-block-paragraph">一、煤气管道基础工况选配要求</p>



<ol class="wp-block-list">
<li>介质特性：高炉煤气、焦炉煤气含粉尘、焦油、冷凝水，易粘附节流面与取压口，流速波动大，低负荷时存在小流量测量偏差；</li>



<li>安全防爆要求：煤气输送区域为1区爆炸危险环境，电气部件必须具备正规防爆资质，杜绝电火花引发燃爆、中毒事故；</li>



<li>计量用途：分为内部能耗核算、环保排污计量，关键点位需稳定连续输出可追溯流量数据；</li>



<li>环境条件：多为露天厂区、高温厂房，仪表需防尘防水、耐高低温，支持无人值守远程数据采集。</li>
</ol>



<p class="wp-block-paragraph">二、防爆等级与壳体选配硬性规范<br>煤气危险区域统一选用<strong>Ex d IIB T6隔爆一体式结构</strong>，差压变送仓、显示仓完全独立密封，可燃煤气无法侵入电路板。出线口装配防爆填料函，密封线缆间隙，防止煤气沿管线窜入仪表内部。<br>整机防护等级不低于IP65，外壳采用防腐铸铝喷涂，抵御户外雨水、粉尘、焦油挥发侵蚀；电路内部灌胶处理，避免昼夜温差凝露造成短路故障。简易本安型不可用于煤气主管连续计量，防爆安全余量不足，不符合厂区安监验收标准。</p>



<p class="wp-block-paragraph">三、节流本体与耐磨材质选配标准</p>



<ol class="wp-block-list">
<li>节流板材质：煤气含硬质粉尘冲刷，孔板优先选用304不锈钢，高粉尘高炉煤气工况可选用硬质合金耐磨涂层，延缓刀口磨损，防止长期使用精度衰减；</li>



<li>取压结构：选用法兰平齐取压，无凹槽死角，减少焦油、粉尘淤积堵塞取压孔，相比角接取压更适配脏污煤气介质；</li>



<li>承压法兰：根据管道压力匹配PN16/PN25法兰，配套柔性石墨耐高温密封垫片，杜绝煤气渗漏、有毒气体外泄风险。</li>
</ol>



<p class="wp-block-paragraph">四、一体化温压补偿性能选配要点<br>煤气密度随温度、压力变化明显，无补偿计量误差极大。设备内置温度、压力传感元件，实时采集工况参数，自动换算标况体积流量，无需额外加装独立积算仪，减少现场管路与接线故障点。<br>量程比按需匹配，煤气峰谷负荷差距大，优先中等量程比机型兼顾高低流速；普通能耗监测选用1.5级精度，环保在线监测点位升级1.0级，保障数据合规可查。</p>



<p class="wp-block-paragraph">五、防堵配套与安装施工规范</p>



<ol class="wp-block-list">
<li>前置过滤配件：仪表前端加装Y型煤气专用过滤器，拦截粉尘、焦油颗粒，保护孔板刀口与取压通道，配套旁路三通阀，清洗滤芯无需全线停气；</li>



<li>直管段要求：上游≥10DN、下游≥5DN平直管道，远离风机、弯头、阀门等紊流部件，避免流场紊乱导致流量跳变；</li>



<li>安装姿态：水平管道侧面取压，防止底部冷凝水、焦油堆积封堵取压口；管道高点增设自动排气阀，消除气液两相干扰差压信号；</li>



<li>防爆布线：使用防爆屏蔽电缆穿金属管敷设，与风机、变频器动力电缆分开，独立接地屏蔽，降低电磁干扰。</li>
</ol>



<p class="wp-block-paragraph">六、信号输出与厂区自控配套<br>标配4-20mA模拟信号实时上传瞬时流量，搭载RS485 Modbus通讯可接入DCS、SCADA系统，远程读取累积气量、介质温压、设备故障代码。就地防爆液晶屏幕支持红外无开盖参数调试，现场操作安全便捷；断电自动保存累计流量，数据防篡改，满足月度煤气消耗统计对账。</p>



<p class="wp-block-paragraph">七、日常运维长效保障措施</p>



<ol class="wp-block-list">
<li>定期清理前置过滤器滤芯，防止杂质持续磨损孔板；</li>



<li>季度检查取压口、仪表壳体有无焦油淤积、煤气渗漏；</li>



<li>每年送检校准仪表零点与量程，维持计量精度；</li>



<li>冬季露天管廊引压部位增设伴热保温，避免冷凝水结冰堵塞取压通道。</li>
</ol>



<p class="wp-block-paragraph">八、选配总结<br>煤气管道计量仪表选配核心围绕隔爆安全、耐磨防堵、一体化温压补偿三大要点。一体式结构省去繁杂引压管路，降低脏污煤气介质堵塞概率，适配焦化、冶金各类煤气输送管线，长期稳定完成能耗统计、环保在线监测工作，兼顾安全生产与运维便捷性。</p>
<p><a href="https://www.zhanfengdesign.com/9383/">防爆一体化孔板流量计煤气管道选配规范</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.zhanfengdesign.com/9383/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>孔板流量计选型参考要素，介质与现场工况匹配梳理</title>
		<link>https://www.zhanfengdesign.com/9142/</link>
					<comments>https://www.zhanfengdesign.com/9142/#respond</comments>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Wed, 24 Jun 2026 09:49:50 +0000</pubDate>
				<category><![CDATA[孔板流量计技术文章]]></category>
		<category><![CDATA[技术文章]]></category>
		<category><![CDATA[孔板流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false">https://www.zhanfengdesign.com/?p=9142</guid>

					<description><![CDATA[<p>一、介质相关选型要素 二、节流件与取压方 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/9142/">孔板流量计选型参考要素，介质与现场工况匹配梳理</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">一、介质相关选型要素</p>



<ol class="wp-block-list">
<li>介质物相分类（气体 / 液体 / 蒸汽）<br>不同物相流体配套辅件、取压布置存在明显区别：<br>1）常温气体（天然气、压缩空气、氮气）：选用标准孔板，取压管路增设排水阀，避免管路凝液积聚干扰差压；<br>2）常温洁净液体（清水、轻质油品）：标准孔板即可，取压口侧向安装，减少气体滞留；<br>3）饱和 / 过热高温蒸汽：配套冷凝罐，平衡高低压侧冷凝液高度，防止高温蒸汽直接接触变送器膜片。</li>



<li>介质洁净度、固体杂质含量<br>根据介质沉淀、颗粒情况选择孔板类型，规避节流孔堵塞：<br>1）洁净无杂质单相流体：选用标准同心孔板，结构简单，成本可控；<br>2）含细微泥沙、油污、悬浮物介质：选用偏心孔板或圆缺孔板，大流通底部减少固体沉积；<br>3）高固含量、大颗粒、易结焦浆液介质：孔板节流口极易淤积堵死，不建议选用<a href="https://www.zhanfengdesign.com/kbllj/">孔板流量计</a>，更换其他适配仪表。</li>



<li>介质腐蚀特性<br>依据介质腐蚀程度匹配节流件、法兰材质：<br>1）空气、清水、洁净天然气等中性介质：节流件选用 304 不锈钢，本体碳钢；<br>2）含微量硫化物、弱酸碱工艺流体：全套过流接触部件采用 316L 不锈钢；<br>3）高酸性、强氯化物腐蚀介质：可选用哈氏合金等特种材质节流件；腐蚀程度过高且无适配材质时更换仪表类型。</li>



<li>介质结垢、凝露、凝固特性<br>1）易结垢胶质介质：优先偏心 / 圆缺孔板，缩短定期清理周期；<br>2）低温易凝介质：取压管路配套伴热保温，防止介质凝固堵塞取压通道；<br>3）高温蒸汽、热油：核对密封件、节流件长期耐温参数，选用耐高温垫片。</li>
</ol>



<p class="wp-block-paragraph">二、节流件与取压方式选型</p>



<ol class="wp-block-list">
<li>孔板结构类型适配场景<br>1）标准同心孔板：洁净气体、清水、蒸汽通用，对直管段要求严格；<br>2）偏心孔板：介质含少量固体颗粒、易沉淀液体；<br>3）圆缺孔板：高杂质污水、原油等底部易沉积介质。</li>



<li>三种主流取压方式区分<br>1）角接取压：结构紧凑，适配中小口径管道，多用于洁净气体、轻质液体；<br>2）法兰取压：拆装维护便捷，通用型强，液体、气体、蒸汽管线均可使用；<br>3）径距取压：测量稳定性好，适合大口径高温高压长周期计量管线。</li>



<li>孔径比 β 值匹配流量区间<br>1）小 β 值：流通面积小，差压信号明显，适合小流量监测；<br>2）大 β 值：流通阻力低，压力损失小，适合大流量、低压管网；<br>选型时结合管路常规流量区间，控制 β 值在合理区间，兼顾信号辨识度与压力损耗。</li>
</ol>



<p class="wp-block-paragraph">三、流量、差压量程匹配要素<br>1.统计管路日常工况最小、最大流量，常规工作流量落在差压变送器量程中段，计量数据更平稳；<br>2.高粘度、高杂质流体流动阻力偏大，同等流量下差压数值偏高，变送器量程预留余量；<br>3.贸易计量、能耗统计场景，配套温压补偿组件，将工况流量换算为标准状态流量；<br>4.流量波动幅度大的管线，搭配差压缓冲罐，稳定输入变送器的差压信号。</p>



<p class="wp-block-paragraph">四、温度、压力工况匹配</p>



<ol class="wp-block-list">
<li>介质温度<br>1）常温流体：四氟、柔性石墨常规密封组件；<br>2）中高温蒸汽、导热油：金属缠绕耐高温垫片，配套冷凝罐 / 散热装置；<br>3）户外低温管线：取压管整体保温伴热，防止介质凝固、水汽结冰堵塞管路。</li>



<li>管路承压等级<br>按照系统长期工作压力、瞬时冲击压力，匹配对应压力等级法兰、节流装置壳体与密封结构；高压高温管网选用加厚高压一体式节流装置。</li>
</ol>



<p class="wp-block-paragraph">五、现场管道与安装条件选型</p>



<ol class="wp-block-list">
<li>管道口径与连接方式<br>1）DN50~DN125 中小口径：夹装式孔板，拆装简便；<br>2）DN150 及以上工业主干管线：法兰一体式节流装置，承压稳定性更强。</li>



<li>直管段空间条件<br>标准同心孔板对上下游直管段长度要求较高；现场弯头、阀门密集、直管段不足时，配套管道整流器优化流场；偏心、圆缺孔板对流场畸变容忍度略优于标准孔板。</li>
</ol>



<p class="wp-block-paragraph">六、差压变送与电气环境配置<br>1.普通室内无易燃易爆介质厂房：通用型差压变送器，4-20mA 标准信号输出；<br>2.燃气、化工防爆生产区域：选用对应防爆等级变送组件；<br>3.露天、地下管廊潮湿点位：变送器加装防雨防护箱体，取压管路做防水包裹；<br>4.中控远程采集流量数据：选用支持 RS485 Modbus 通讯的智能差压变送器；<br>5.周边变频器、大功率风机较多工况，配套双层屏蔽信号线缆，降低电磁干扰。</p>



<p class="wp-block-paragraph">七、配套辅件匹配梳理<br>1.冷凝罐：蒸汽管线标配，平衡高低压侧冷凝液位；<br>2.伴热保温套件：低温易凝固介质管路使用；<br>3.排污 / 排气阀：气体管路排凝液、液体管路排积气；<br>4.整流器：直管段不足管线优化流场；<br>5.旁路管路：便于节流件离线检修、变送器零点校准，无需全线停产。</p>



<p class="wp-block-paragraph">八、工况适配汇总<br>适配场景<br>洁净气体、清水、高温蒸汽、轻质油品等单相流体；电厂热力管网、燃气输送主管、工厂循环水、压缩空气能耗监测；高温高压长周期计量管线，预算管控的常规流量监测点位。<br>不适配场景<br>高固含量浆液、高粘度粘稠介质、易严重结焦堵塞管线；流量长期极小，差压信号辨识度不足；对管路压力损耗控制严格的低压管网。</p>
<p><a href="https://www.zhanfengdesign.com/9142/">孔板流量计选型参考要素，介质与现场工况匹配梳理</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.zhanfengdesign.com/9142/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>标准孔板流量计的工作原理</title>
		<link>https://www.zhanfengdesign.com/1558/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 09:39:44 +0000</pubDate>
				<category><![CDATA[孔板流量计技术文章]]></category>
		<category><![CDATA[技术文章]]></category>
		<category><![CDATA[孔板流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>标准孔板流量计是将标准孔板与多参数差压变 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1558/">标准孔板流量计的工作原理</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>标准孔板流量计是将标准孔板与多参数差压变送器（或差压变送器、<a href="https://www.zhanfengdesign.com/wdbsq/">温度变送器</a>及压力变送器）配套组成的高量程比差压流量装置，可测量气体、蒸汽、液体及引的流量，广泛应用于石油、化工、冶金、电力、供热、供水等领域的过程控制和测量。节流装置又称为差压式流量计，是由一次检测件（节流件）和二次装置（差压变送器和流量显示仪）组成广泛应用于气体。蒸汽和液体的流量测量。具有结构简单，维修方便，性能稳定。在已知有关参数的条件下，根据流动连续性原理和伯努利方程可以推导出差压与流量之间的关系而求得流量。</div>
<div></div>
<div>其基本公式如下：</div>
<div><img decoding="async" style="width: 256px; height: 97px;" src="/uploads/allimg/210619/1-21061910510M14.jpg" alt="" /></div>
<div>c－流出系数　无量纲</div>
<div></div>
<div>d－工作条件下节流件的节流孔或喉部直径</div>
<div></div>
<div>D－工作条件下上游管道内径</div>
<div></div>
<div>qm－质量流量　Kg/s</div>
<div></div>
<div>qv－体积流量　m3/s</div>
<div></div>
<div>?－直径比d/D 无量纲</div>
<div></div>
<div>流体的密度Kg/m3</div>
<div></div>
<div>可膨胀性系数　无量纲</div>
<p><a href="https://www.zhanfengdesign.com/1558/">标准孔板流量计的工作原理</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>标准孔板流量计哪几部分组成</title>
		<link>https://www.zhanfengdesign.com/1559/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 09:39:15 +0000</pubDate>
				<category><![CDATA[孔板流量计技术文章]]></category>
		<category><![CDATA[技术文章]]></category>
		<category><![CDATA[孔板流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>基本结构 1.节流件：标准孔板、标准喷嘴 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1559/">标准孔板流量计哪几部分组成</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>基本结构</div>
<div>1.节流件：标准孔板、标准喷嘴、长径喷嘴、1／4圆孔板、双重孔板、偏心孔板、圆缺孔板、锥形入口孔板等</div>
<div>2.取压装置：环室、取压法兰、夹持环、导压管等</div>
<div>3.连接法兰（家标准、各种标准及其它设计部门的法兰）　、紧固件。</div>
<div>4.测量管</div>
<div>5.<a href="https://www.zhanfengdesign.com/kbllj/">孔板流量计</a>结构图：</div>
<div><img decoding="async" style="width: 250px; height: 150px;" src="/uploads/allimg/210619/1-210619105202S1.jpg" alt="" /></div>
<div>环室取压标准孔板</div>
<div>PN≤2.5</div>
<div></div>
<div><img decoding="async" style="width: 250px; height: 150px;" src="/uploads/allimg/210619/1-21061910521J03.jpg" alt="" /></div>
<div>环室取压标准孔板</div>
<div>4.0≤PN≤6.4</div>
<div></div>
<div><img decoding="async" style="width: 250px; height: 150px;" src="/uploads/allimg/210619/1-210619105230507.jpg" alt="" /></div>
<div>钻孔取压标准孔板</div>
<div>PN≤2.5</div>
<div></div>
<div><img decoding="async" style="width: 250px; height: 150px;" src="/uploads/allimg/210619/1-210619105243J2.jpg" alt="" /></div>
<div>紧固式八槽孔板</div>
<div>PN≤10</div>
<div></div>
<div><img decoding="async" style="width: 250px; height: 150px;" src="/uploads/allimg/210619/1-21061910525B30.jpg" alt="" /></div>
<div>焊接式八槽孔板</div>
<div>PN≤10</div>
<div></div>
<div><img decoding="async" style="width: 250px; height: 150px;" src="/uploads/allimg/210619/1-2106191053113N.jpg" alt="" /></div>
<div>径距取压标准孔板</div>
<div>PN≤2.5</div>
<div></div>
<div><img decoding="async" style="width: 250px; height: 150px;" src="/uploads/allimg/210619/1-2106191053255O.jpg" alt="" /></div>
<div>压透镜垫孔板</div>
<div>PN22，32</div>
<div></div>
<div><img decoding="async" style="width: 250px; height: 150px;" src="/uploads/allimg/210619/1-210619105343917.jpg" alt="" /></div>
<div>法兰取压标准孔板</div>
<div>4.0≤PN≤6.4</div>
<p><a href="https://www.zhanfengdesign.com/1559/">标准孔板流量计哪几部分组成</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>标准孔板流量计维护保养</title>
		<link>https://www.zhanfengdesign.com/1560/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 09:38:52 +0000</pubDate>
				<category><![CDATA[孔板流量计技术文章]]></category>
		<category><![CDATA[技术文章]]></category>
		<category><![CDATA[孔板流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>(1)仪表检修后投用，对于测量气体的孔板 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1560/">标准孔板流量计维护保养</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>(1)仪表检修后投用，对于测量气体的孔板流量计，要排掉引压管、差压变送器内积液；对于测量油品的，要排掉测量系统内的水、气体，并使得介质充满管道；同时检查各附属接头、阀门、卡套有无泄露，零点是否漂移。</div>
<div></div>
<div>(2)孔板差压变送器、现场接线箱等部位定期做防水检查，特别是南方雨季、台风来临前，防止接线端子、电路板进水引起仪表故障或出现波动，还有对差压变送器定期检查零点是否漂移。</div>
<div></div>
<div>(3)<a href="https://www.zhanfengdesign.com/kbllj/">标准孔板流量计</a>，配合工艺做好排液、排气等工作，如分馏塔回流带水，仪表专业要在工艺操作稳定后及时排液、排气，校验流量是否符合当前物料平衡要求。</div>
<div></div>
<div>(4)针对引压管经常带水或测量介质带腐蚀性的情况，仪表专业可通过打压泵给高低压引压管平衡灌隔离液(选择合适比重的隔离液)的方式，避免因引压管带水导致流量计测量或介质腐蚀变送器。对需要灌隔离液的流量计，要控制好打压压力，并注意排除气泡，调校好仪表零位，并按规范步骤投用仪表。</div>
<div></div>
<div>(5)加强仪表维护人员技能培训，在投用过程中要避免变送器单向受压、或变送器泄漏，不能让导压管内凝结水或隔离液流失；不可使变送器单受热，对于蒸汽，待导压管充满凝结水后方可启动变送器。</div>
<div></div>
<div>(6)在冬季，特别是在北方，对于凝点比较低的介质，仪表专业与工艺专业要配合做好引压管线保温、伴热工作，避免因天气温度过低导致介质在引压管处冷凝，引起仪表测量不准。</div>
<div></div>
<div>(7)停工检修时，蒸汽吹扫要提前隔离变送器避免高温损坏，对长期使用或经常波动偏差的孔板进行下线检查，检查直管段堵塞情况、孔板直角入口边缘光洁度和锐利度、孔板表面垂直度、平行度等是否符合要求，如有超出设计标准，要及时对孔板进行修正或更换。</div>
<div></div>
<div>(8)定期检查孔板设计参数与实际参数是否一致，使得孔板流量计的测量范围满足精度要求，如因生产条件变化导致孔板测量不准，仪表维护人员不可随意更改变送器参数。</div>
<div></div>
<div>结束语：在日常生产操作过程中，标准孔板流量计出现异常或偏差时，仪表维护人员要及时排除是否由工艺工况改变造成，然后再进一步排除是否由差压变送器、三阀组或孔板本身引起等故障，及时排查出产生偏差的原因并解决，为生产操作提供可靠性参考，这就要求维护人员对本装置工艺流程及介质特性有一个相对深入的了解，为快速判断仪表故障及与工艺操作员有效沟通奠定基础。</div>
<p><a href="https://www.zhanfengdesign.com/1560/">标准孔板流量计维护保养</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>差压孔板流量计的工作原理</title>
		<link>https://www.zhanfengdesign.com/1561/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 09:38:03 +0000</pubDate>
				<category><![CDATA[孔板流量计技术文章]]></category>
		<category><![CDATA[技术文章]]></category>
		<category><![CDATA[孔板流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>差压孔板流量计在各个行业都应用广泛、历史 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1561/">差压孔板流量计的工作原理</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>差压孔板流量计在各个行业都应用广泛、历史悠久，在各类流量仪表中其使用量占居首位。近年来，由于各种新型流量计的不断涌现，致使它的用量有所下降。</div>
<div></div>
<div><a href="https://www.zhanfengdesign.com/kbllj/">差压孔板流量计</a>由三部分组成，即由节流装置、导压管和差压计。差压孔板流量计是利用流体流动的节流原理来实现流量测量的。节流原理是流体在有节流装置的管道中流动时，在节流装置前后的管壁处，流体的静压力产生差异的现象.</div>
<div></div>
<div>1、差压孔板流量计的原理</div>
<div>流动流体的能量有静压能和动能两种形式.流体具有静压能是因为有压力，具有动能是因为有流动速度，在一定条件下，这两种形式的能量是可以相互转化.根据能量守恒定律，在没有外加能量的前提下，流体所具有的静压能和动能，再加上用以克服流体流动阻力的能量损失，其能量总和是相等的。</div>
<div><img decoding="async" style="width: 603px; height: 444px;" src="/uploads/allimg/210619/1-210619105511F6.gif" alt="" /></div>
<div>图1表示在节流装置前后截面Ⅰ、Ⅱ及Ⅲ处流体压力与速度的分布情况。流体在到达截面Ⅰ之前，以一定的流速v1流动，此时静压力为p1。在接近节流装置时，由于遇到节流装置的阻碍，使靠近管壁处的流体受到节流装置的阻挡作用，使部分动能转化为静压能，使得节流装置入口端面靠近管壁处的流体静压力升高，并且远大于管径中心处的压力，因此节流装置入口端面处产生一径向压差。</div>
<div></div>
<div>在径向压差的作用下，流体产生径向加速度，从而使靠近管壁处的流体质点的流动方向倾斜于管道中心轴线，出现缩脉现象。由于受到惯性作用，流速的最小截面并不在节流装置的孔口处，而是经过节流装置之后仍继续收缩，到截面Ⅱ处流速达到最小，此时流速大，即v2，之后流速又逐渐扩大，至截面Ⅲ后完全恢复，流速逐渐降到原值，即v3=v1。</div>
<div></div>
<div>由于节流装置产生流速的局部收缩现象，使流体的流速随之变化，即动能也跟着变化.根据能量守恒定律，表征流体静压能的静压力也要变化。在截面Ⅰ处，流体具有静压力p1。在截面Ⅱ处，流速增到最大v2，静压力就降到最小p2，而后又随着流速的恢复而恢复。由于在节流装置端面处流通面突然缩小，而节流装置之后流通面积突然又扩大，使流体形成局部涡流，部分能量被消耗，同时流体流经孔板时，为克服摩擦力也需消耗能量，所以流体在截面Ⅲ处的静压力p3不能恢复到原值p1，而产生的压力损失.截面Ⅰ与Ⅱ处的压差（δp=p1- p2）与流体在节流装置前的流量有一一对应关系，只要测出节流装置前后的压差大小即可表示流量大小。</div>
<div><img decoding="async" style="width: 264px; height: 266px;" src="/uploads/allimg/210619/1-210619105531919.jpg" alt="" /></div>
<div></div>
<div>2、差压式流量方程推导</div>
<div>流体流经节流装置时，不对外做功，没有外加能量，流体本身也没有温度变化.在管道内流动的流体，对于管道中任意两个截面都符合伯努利方程，现选截面Ⅰ和Ⅱ（见图2）进行分析。</div>
<div>流体的伯努利方程：</div>
<div><img decoding="async" style="width: 332px; height: 389px;" src="/uploads/allimg/210619/1-21061910554a48.jpg" alt="" /></div>
<div></div>
<div>从上式可以看出：流量与压力差ΔP的平方根成正比。</div>
<div>对于可压缩流体流量监测，因其易发生体积变化，所以在流量方程中要引入膨胀系数ε，则流量基本方程可写为：</div>
<div><img decoding="async" style="width: 308px; height: 102px;" src="/uploads/allimg/210619/1-210619105604149.jpg" alt="" /></div>
<div></div>
<div>式中：qv、qm分别为被测介质的体积流量和质量流量；A0节流装置的开孔截面积；ρ节流装置前的流体密度。</div>
<div>式（13）、（14）为节流式流量计的流量方程，即压差和流量间的定量关系。</div>
<div>由流量基本方程可以看出，在其他条件不变的前提下，流量与压差的平方根成正比，要知道流量与压力差的真实关系，关键在于α的取值。α是受许多因素影响的综合性系数，对于标准节流装置，其值可以从有关手册中查出；对于非标准节流装置，其值主要由实验方法得到。</div>
<p><a href="https://www.zhanfengdesign.com/1561/">差压孔板流量计的工作原理</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>差压孔板流量计如何选型</title>
		<link>https://www.zhanfengdesign.com/1562/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 09:37:32 +0000</pubDate>
				<category><![CDATA[孔板流量计技术文章]]></category>
		<category><![CDATA[技术文章]]></category>
		<category><![CDATA[孔板流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>孔板流量计差压值如何选取，该选多大的？和 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1562/">差压孔板流量计如何选型</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>孔板流量计差压值如何选取，该选多大的？和很多因素有关，比如：不确定度，前后直管段等，所以说在计算<a href="https://www.zhanfengdesign.com/kbllj/">孔板流量计</a>和V锥流量计的开孔直径时，千万不能盲目的选取大的差压，而要综合考虑一些相关因素。生产节流装置厂商都知道，在对孔板流量计等节流装置根据现场参数计算开孔直径的时候，会涉及到这么一个问题，就是差压变送器的差压值如何选取的问题？我们平时生产的过程中，不能一味的建议我们的用户选择大的差压值，要做到真正为客户负责，为企业负责。</div>
<div></div>
<div>1.差压值大时，β值变小，推荐使用的小雷诺数较小。这样的话，使得实际雷诺数有可能远大于推荐使用的雷诺数，于是流量系数趋于稳定，测量精度也就提高。</div>
<div></div>
<div>2.差压值大时，所需要的小直管段可以短些。针对这个特点，对于孔板流量计来说，考虑各方面经济的因素，应该选取差压的那个开孔值；而V锥流量计则相对好点了，对于现场流体是牛顿流体的话，本身V锥流量计的直管段要求就比较低，即使短些的话，相比而言的话，也不存在了</div>
<div></div>
<div>3.而对于差压变送器来说，差压大的比差压小的更加稳定。上面介绍的基本全是选取差压大的时候的优点，不过很多时候，发展到了一定程度，必将相对的带来一定的弊端。</div>
<div></div>
<div>熟悉孔板流量计和V锥流量计加工工艺的人，应该知道，当差压选取过大的时候，那么导致的直接后果就是开孔变的很小，那么相对的就是压力损失也很大，孔板流量计本来压力损失就很大，如果再加上这个的话，那么对整个工艺系统来说，由于这个压力损失而造成的费用是相当可观的；V锥流量计相比起来，稍微适中点了。</div>
<p><a href="https://www.zhanfengdesign.com/1562/">差压孔板流量计如何选型</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>差压孔板流量计安装要求</title>
		<link>https://www.zhanfengdesign.com/1563/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 09:37:10 +0000</pubDate>
				<category><![CDATA[孔板流量计技术文章]]></category>
		<category><![CDATA[技术文章]]></category>
		<category><![CDATA[孔板流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>流量测量的精度和差压孔板流量计安装是否符 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1563/">差压孔板流量计安装要求</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>流量测量的精度和<a href="https://www.zhanfengdesign.com/kbllj/">差压孔板流量计</a>安装是否符合要求有很大关系，一般要求如下：</div>
<div></div>
<div>1.安装时必须保证节流件开孔与管道同心.节流件端面与管道轴线垂直。节流件上、下游必须有一定长度的直管段</div>
<div></div>
<div>孔板流量计需前10D，后5D</div>
<div></div>
<div>V锥流量计需前5D，后1-3D</div>
<div></div>
<div>弯管流量计就安装在弯头上。</div>
<div></div>
<div>2.导压管尽量按最短距离敷设在3-50m之内，为了不在此管中聚集气体和水分，导压管应垂直安装。安装时其倾斜率不应小于1:10.异管用直径10-12mm的铜、铝或钢管。</div>
<div></div>
<div>3.测量液体流量时，最好差压计安装在低于节流装置的位置. 如果一定要安装在上方.在连接管路最高点要装带阀门的集气器，在最低点安装带阀门的沉降器，以便排出导管中气体及沉积物。</div>
<div></div>
<div>4.测量气体流量时，最好把差压计装在高于节流装置处，如定要装在低处时，在导压管最低处要装置沉降器，以便排出冷凝液及污物。</div>
<div></div>
<div>5.测量粘性、腐蚀性或易燃介质时，应安装隔离器。隔离器的用途是保护差压计不受被测介质的腐蚀和沾污.隔离器是两个相同容器，内部充以化学性质稳定且与被测介质不起作用和溶融的液体。为了方便使用.有的欢压计本身已充有工作液，用隔离膜与被测介质隔开.</div>
<div></div>
<div>6.测量蒸气流量时，差压汁与节流装锐之间的安装与测液体时基本相同，为保证两导管内冷凝水位在同一高度，在靠近节流装置附近.安装冷凝器.此外，它还可防止热汽作用于差压计上，冷凝器是两个并排安装的容器。下部与差压计相通，中间有两个水平孔用异压管与节流装置的取压装置相连。冷凝器中保持恒定液位。</div>
<div></div>
<div>7，特别注意在比较寒冷的地区要做好保温和伴热处理，防止引压管上冻。</div>
<p><a href="https://www.zhanfengdesign.com/1563/">差压孔板流量计安装要求</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>一体化孔板流量计的优缺点</title>
		<link>https://www.zhanfengdesign.com/1564/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 09:36:44 +0000</pubDate>
				<category><![CDATA[孔板流量计技术文章]]></category>
		<category><![CDATA[技术文章]]></category>
		<category><![CDATA[孔板流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>一体化孔板流量计是将标准孔板与多参数差压 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1564/">一体化孔板流量计的优缺点</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>一体化孔板流量计是将标准孔板与多参数<a href="https://www.zhanfengdesign.com/cybsq/">差压变送器</a>（或差压变送器、温度变送器及压力变送器）配套组成的高量程比差压流量装置，可测量气体、蒸汽、液体及引的流量，广泛应用于石油、化工、冶金、电力、供热、供水等领域的过程控制和测量。节流装置又称为差压式流量计，是由一次检测件（节流件）和二次装置（差压变送器和流量显示仪）组成广泛应用于气体。蒸汽和液体的流量测量。具有结构简单，维修方便，性能稳定。</div>
<div></div>
<div>一、优点</div>
<div>1、标准节流件是全用的，并得到了国际标准组织的认可，无需实流校准，即可投用，在流量传感器中也是唯一的；</div>
<div>2、结构易于复制，简单、牢固、性能稳定可靠、价格低廉；</div>
<div>3、应用范围广，包括全部单相流体(液、气、蒸汽)、部分混相流，一般生产过程的管径、工作状态(温度、压力)皆可以测量；</div>
<div>4、检测件和差压显示仪表可分开不同厂家生产，便于专业化规模生产。</div>
<div></div>
<div>二、缺点</div>
<div>1、测量的重复性、精确度在流量传感器中属于中等水平，由于众多因素的影响错综复杂，精确度难于提高；</div>
<div>2、范围度窄，由于流量系数与雷诺数有关,一般范围度仅3∶1～4∶1；</div>
<div>3、有较长的直管段长度要求，一般难于满足。尤其对较大管径，问题更加突出；</div>
<div>4、压力损失大；</div>
<div>5、孔板以内孔锐角线来保证精度，因此传感器对腐蚀、磨损、结垢、脏污敏感，长期使用精度难以保证，需每年拆下强检一次；</div>
<div>6、采用法兰连接，易产生跑、冒、滴、漏问题，大大增加了维护工作量。</div>
<p><a href="https://www.zhanfengdesign.com/1564/">一体化孔板流量计的优缺点</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>一体化孔板流量计用途</title>
		<link>https://www.zhanfengdesign.com/1565/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 09:36:01 +0000</pubDate>
				<category><![CDATA[孔板流量计技术文章]]></category>
		<category><![CDATA[技术文章]]></category>
		<category><![CDATA[孔板流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>越来越多厂家都会开始询问一体化孔板流量计 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1565/">一体化孔板流量计用途</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>越来越多厂家都会开始询问<a href="https://www.zhanfengdesign.com/kbllj/">一体化孔板流量计</a>的事情了，可以看得出人们不但越来越熟悉这类产品，并且产生的疑问也会更多，如果在了解之后，确定产品各方面都符合需求，自然就可以放心购买了。紧接着会提到更多的情况，让朋友们弄清楚该产品的用途以及适用范围是什么样的。</div>
<div></div>
<div>1、产品的用途</div>
<div>即便都是流量计，也会由于不一样的生产技术和功能，而有着不同的使用途，因此当我们在挑选产品的时候，不能盲目的认为所有流量计都可以起到相同的使用效果，抱着这样的想法选择产品，自然不会有满意的结果。一体化孔板流量计的用途非常广泛，所以才能够更受欢迎，它主要可以计量管道液体、气体以及蒸汽等。</div>
<div></div>
<div>2、适用的范围</div>
<div>接下来还要了解到哪些与一体化孔板流量计相关的事情呢？相信朋友们对于该产品的适用范围，也会有着很大的好奇心，想要弄清楚答案是什么，并不会有太大的难度。该产品既能够在石油、化工领域中起到理想的使用效果，同样也能够在冶金、电力等行业内进行使用。</div>
<div></div>
<div>一体化孔板流量计的用途是什么？适用于哪些行业</div>
<div>通过简单的介绍内容，就可以让朋友们掌握到更多有用的信息了，自然不会像之前一样迷茫不已，也不清楚要怎么进行选择了。一体化孔板流量计确实是口碑非常好的产品，只要是专业的厂家，都可以通过先进的技术以及较好的材质进行生产，保证了产品的使用稳定性，也能够有着更长久的使用寿命。</div>
<p><a href="https://www.zhanfengdesign.com/1565/">一体化孔板流量计用途</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>一体化孔板流量计的安装与维护</title>
		<link>https://www.zhanfengdesign.com/1566/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 09:35:40 +0000</pubDate>
				<category><![CDATA[孔板流量计技术文章]]></category>
		<category><![CDATA[技术文章]]></category>
		<category><![CDATA[孔板流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>一体化孔板流量计安装 节流装置安装的正确 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1566/">一体化孔板流量计的安装与维护</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>一体化孔板流量计安装</div>
<div>节流装置安装的正确与否直接影响其对流量测量的精确程度，因此掌握节流装置正确安装是非常重要的。</div>
<div>1.1基本要求：</div>
<div>1.1.1流体必须充满测量管道，并且连续不断的流过节流件，不能适用于脉动流和临界的流量测量。</div>
<div>1.1.2流体在物理上和热力学上必须为均匀的单相流体；流体流经节流装置时不得发生相变；流束必须与管道平行，不得有旋转流。</div>
<div>1.1.3对于新设管路系统，必须先经扫线后再安装节流装置，以防管内杂物堵塞或损伤节流装置。</div>
<div>1.1.4安装前应仔细核对节流装置的编号、位号、规格是否与管道情况、流量范围等参数相符。在取压口附近标有“+”的一端应与流体上游管段联接，标有“—”的一端应与流体下游管段联接。</div>
<div>1.1.5节流装置的中心线应当与管道中心线同轴。</div>
<div>1.2对管道的要求：</div>
<div>1.2.1管道垂直度：节流件上游端面与管道轴线的垂直度不大于1°。</div>
<div>当节流件的轴线与上下游侧管道轴线之间距离e满足下式时，流出系数C无附加不确定度。</div>
<div><img decoding="async" style="width: 197px; height: 36px;" src="/uploads/allimg/210622/1-210622110S4109.jpg" alt="" /></div>
<div>如果上式不能满足，而满足下式时，流出系数C的不确定度应算术相加±3%</div>
<div><img decoding="async" style="width: 376px; height: 32px;" src="/uploads/allimg/210622/1-210622110TI25.jpg" alt="" /></div>
<div>1.2.2节流装置前后应配有一段测量管，至少保持前10D、后5D的等径直管段，以保证测量精度（经典文丘里管前2～5D、后1～3D）。详见：GB/T2624-2006流量测量节流装置用孔板、喷嘴和文丘里管测量充满圆管的流体流量或计算数据表提供相关数据。</div>
<div>1.2.3节流装置安装在垂直管道上时，下端取压口要与上端取压口在同一水平面上。节流装置安装在水平管道上时（包括斜管道），取压口位置的选择取决于被测介质的特性，见图示：</div>
<div><img decoding="async" style="width: 550px; height: 179px;" src="/uploads/allimg/210622/1-210622110Z05D.jpg" alt="" /></div>
<div>组件出厂时，取压口、导压管均设在二螺丝栓孔中间。现场法兰焊接时应注意螺孔及取压口相对位置。</div>
<div>1.2.4在节流件前后若需安装阀门，最好选闸阀且在运行中全开；调节阀则应在下游5D之后的管路中。</div>
<div></div>
<div>对差压引出管路的要求</div>
<div>1.导压管应按被测流体的性质参数使用耐压，耐腐蚀的材料制造。其内径不得小于6mm，长度最好在16m之内。</div>
<div>2.引压管路的内径与管路长度和介质脏污程度有关，通常在25米以内用内径为8-12mm的管子。测量煤气可适当加粗到DN15。</div>
<div>3.导压管应垂直或倾斜敷设，其倾斜度不得小于1/12；粘度较高的流体，其倾斜度还应增大，当差压信号传送距离大于30m时，导压管应分段倾斜，并且在最高点和最低点分别装设集气器（阀）和沉降器（阀）。</div>
<div>4.测量液体流量时引压管水平段应在同一水平面内。若是在垂直管道上安装节流件，引压短管之间相距一定的距离（垂线方向），这对差压变送器的零点有影响，应通过“零点迁移”来校正。</div>
<div>5.引压管路应有牢固的支架托承，两根取压管路应尽可能互相靠近并远离热源或震动源。测量水蒸气流量时，应用保温材料一同包扎，必须时（如气温0℃以下）加伴热管防止结冰。在测量脏污流量时，应附设隔离器或沉降器。</div>
<div>6.引压管路内必须始终保持单相流体状态。被测流体是气体时，引压管路（包括差压计的压力腔）内全部是气相；被测流体是液体时，引压管路内全部是液相，绝对不能有气泡。</div>
<div></div>
<div><a href="https://www.zhanfengdesign.com/kbllj/">一体化孔板流量计</a>使用与维护</div>
<div>1.使用注意事项</div>
<div>1.1.1新表安装完成，一定检查各个焊接点有无虚焊、漏焊，在吹扫前不要安装节流件，待管路吹扫结束安装节流件；对于节流件焊接无法取出节流装置安装，先吹扫管路，在切开安装管路，清扫出管道内杂质，焊接节流装置，注意取压口方向。</div>
<div>1.1.2三阀组（五阀组）与差压变送器连接是内六角螺丝连接，中间有密封垫，螺丝连接要平衡用力，防止螺丝不平衡造成泄漏；各个阀门安装时，须将阀门内部密封垫取出，待焊接冷却后，再安装密封垫。</div>
<div>1.1.3差压变送器两取压端要在同一水平状态，两取压端无垂直高度差。</div>
<div>1.1.4新表或停用一段时间后重新启用的节流装置，投用前应检查引压管路有无堵塞或泄漏，对液体介质应在引压管路内充满清洁的水或其他导压液体，注意排放管路内混进的气体，对气体介质应注意排放管路内积液。</div>
<div>1.1.5投运前打开“三阀组”中的平衡阀，关严正负取压管路上的阀门，检查、校正差压变送器的零点，一定注意“零点”是在正负压力腔完全等压（即差压等于0）时，核查调整差压变送器。</div>
<div>1.16在流体流动状态下即使全开“平衡阀”，只要不关严正负取压管路上的取压阀门，也不能核查零点。因为平衡阀本身有阻力，不能完全平衡正负压力腔的压力，即达不到“零差压”状态。</div>
<div>1.1.7测量脏污流体流量时，一定要配置沉降器或隔离器。注意导压流体的进口、出口及排污口的位置如何合理选择，以达到排污目的。</div>
<div>1.1.8测量腐蚀性流体流量时，一定要选用合适的隔离器，根据介质比重选用合适的隔离液，并注意合理选择隔离液与被测流体的入口。</div>
<div>1.1.9节流装置的设计参数是否与实际参数相符，直接关系到测量精度。节流装置投入使用时，测得的参数如果处于设计参数的范围内，测量精度一般不会超过设计计算精度；但是如果测得的参数远离设计参数范围（假定节流装置及差压变送器选型、制造、安装均符合要求）则有可能是提供的设计参数有误，应更改设计参数，重新设计计算。</div>
<div></div>
<div>2.2维护注意事项：</div>
<div>2.2.1对于流量装置要定期检查管路，做到测量管路无泄漏。管路积尘要及时清理。差压变送器安装牢固，无使用位移、偏移。差压变送器要避免直接高温、日晒、雨淋、暴露在腐蚀性环境中。</div>
<div>2.2.2对于使用隔离液介质测量，除了管路严格密封外，还必须检查隔离液的高度或位置，对于缺少隔离液要及时补充，对于隔离液高度要两边一致，避免形成液柱差。</div>
<div>2.2.3对于使用反吹扫装置的节流装置，要检查吹扫装置工作情况，如果吹扫装置不能正常工作要及时处理，防止介质堵塞取压口或接流体，使测量装置无法正常工作；吹扫装置不工作时，整个取压管路差压为流体经过节流体形成差压，无外部气源提供任何压力，要防止吹扫装置阀门故障对流量差压影响，出现以上情况要及时处理。</div>
<div>2.2.4日常维护工作主要是清除沉降器或隔离器内的积垢，定期从排污口处放掉，在被测介质是高温高压腐蚀或有毒流体时，清除时要注意安全。</div>
<div>2.2.5差压变送器的零点有时发生漂移，影响测量精度（特别是流量小、差压接近下限值时），要经常校对零点。质量好的差压变送器可根据经验延长校零周期至1年，而质量差的则可能数天校一次零点，所以我们建议配用质量好的差压变送器，减轻日常维护工作量。</div>
<div>2.2.6对于液体管路（特别为低温凝结）与蒸汽管路必须注意低温保温，对差压变送器也要做低温保温措施；对于高温汽化液体介质测量，也要注意介质保温，防止介质高温汽化对测量影响。</div>
<p><a href="https://www.zhanfengdesign.com/1566/">一体化孔板流量计的安装与维护</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>孔板流量计常见故障及处理方法</title>
		<link>https://www.zhanfengdesign.com/1567/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 09:35:16 +0000</pubDate>
				<category><![CDATA[孔板流量计技术文章]]></category>
		<category><![CDATA[技术文章]]></category>
		<category><![CDATA[孔板流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>1、孔板流量计的尖锐一侧应该迎向流体流向 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1567/">孔板流量计常见故障及处理方法</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>1、孔板流量计的尖锐一侧应该迎向流体流向为入口端，呈喇叭形的一侧为出口端。如果装反了，显示将会偏小很多。</div>
<div>解决的方法：检查<a href="https://www.zhanfengdesign.com/kbllj/">孔板流量计</a>安装方向，正确安装孔板。</div>
<div></div>
<div>2、孔板的入口边缘磨损</div>
<div>如果孔板使用时间较长，特别是在被测介质夹杂固体颗粒等杂物情况下，都会造成孔板的几何形状和尺寸的变化，如果造成开孔变大或开孔边缘变钝，测量压差就会变小，流量显示就会偏低。</div>
<div>解决方法：对孔板进行重新加工。</div>
<div></div>
<div>3、变送器零点漂移如果使用时间较长，变送器的零点可能会发生漂移，如果是负漂移，显示压差将会减小，显示的流量也会减小。</div>
<div>解决方法：对变送器的零点进行校正。</div>
<div></div>
<div>4、上下游直管段长度不够上下游直管段如果不够长，气体将得不到充分发展，会使计量结果造成较大误差，如果上游在规定直管段内存在多个弯头，计量结果偏低。</div>
<div>解决方法：改造蒸汽管道，是上下游直管段长度达到规定要求。在节流装置前加整流器。</div>
<div></div>
<div>5、差压变送器的三阀组漏气</div>
<div>如果三阀组中的高压阀货平衡阀漏气，将会导致测量差压值减小，测量结果就会偏低。</div>
<div>解决方法：如果三阀组中的高压阀门漏气，将该阀门进行紧固，必要时进行更换，如果三阀组中的平衡阀内漏，将该阀门进行紧固，必要时进行更换。</div>
<p><a href="https://www.zhanfengdesign.com/1567/">孔板流量计常见故障及处理方法</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>平衡孔板流量计工作原理</title>
		<link>https://www.zhanfengdesign.com/1570/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 09:34:41 +0000</pubDate>
				<category><![CDATA[孔板流量计技术文章]]></category>
		<category><![CDATA[技术文章]]></category>
		<category><![CDATA[孔板流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>平衡孔板流量计是将标准孔板与多参数差压变 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1570/">平衡孔板流量计工作原理</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div><a href="https://www.zhanfengdesign.com/kbllj/">平衡孔板流量计</a>是将标准孔板与多参数差压变送器（或差压变送器、温度变送器及压力变送器）配套组成的高量程比差压流量装置，可测量气体、蒸汽、液体及引的流量，广泛应用于石油、化工、冶金、电力、供热、供水等领域的过程控制和测量。节流装置又称为差压式流量计，是由一次检测件（节流件）和二次装置（差压变送器和流量显示仪）组成广泛应用于气体。蒸汽和液体的流量测量。具有结构简单，维修方便，性能稳定。在已知有关参数的条件下，根据流动连续性原理和伯努利方程可以推导出差压与流量之间的关系而求得流量。</div>
<div></div>
<div>其基本公式如下：</div>
<div><img decoding="async" style="width: 256px; height: 97px;" src="/uploads/allimg/210625/1-210625093100O1.jpg" alt="" /></div>
<div>c－流出系数　无量纲</div>
<div>d－工作条件下节流件的节流孔或喉部直径</div>
<div>D－工作条件下上游管道内径</div>
<div>qm－质量流量　Kg/s</div>
<div>qv－体积流量　m3/s</div>
<div>?－直径比d/D 无量纲</div>
<div>流体的密度Kg/m3</div>
<div>可膨胀性系数　无量纲</div>
<div><img decoding="async" style="width: 450px; height: 391px;" src="/uploads/allimg/210625/1-2106250930405X.jpg" alt="" /></div>
<p><a href="https://www.zhanfengdesign.com/1570/">平衡孔板流量计工作原理</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>孔板流量计与平衡孔板流量计的差别</title>
		<link>https://www.zhanfengdesign.com/1571/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 09:34:14 +0000</pubDate>
				<category><![CDATA[孔板流量计技术文章]]></category>
		<category><![CDATA[技术文章]]></category>
		<category><![CDATA[孔板流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>平衡孔板流量计也叫多孔孔板流量计，是一款 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1571/">孔板流量计与平衡孔板流量计的差别</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>平衡孔板流量计也叫多孔孔板流量计，是一款节能型差压流量计，因获得同样的差压值对应～1/3的永久压损。函数型多孔能整理与平衡流场，极大地提高精度和重复性，精度提高可以降低精度成本，压损降低可以节约泵送成本。基本上所有的孔板流量计、锥形、均速管、楔式、涡街、电磁等流量计适应的90%的流量测量场合，都能适用平衡孔板流量计，类似孔板的安装结构，0.3～0.5级精度，短直管段，低压损，宽量程比，不易堵。可测量液体、蒸汽、气体的流量，它广泛应用于石油、化工、冶金、电力、轻工等部门。那么<a href="https://www.zhanfengdesign.com/kbllj/">平衡孔板流量计</a>与孔板流量计又有哪些区别呢？</div>
<div></div>
<div>一、线性度高、重复性好</div>
<div>平衡流量传感器具有对称多孔结构特点，能对流场进行平衡，降低了涡流、振动和信号噪声，流场稳定性大大提高，使线性度比孔板提升了5～10倍，重复性提高了54％，为0.15％，从其综合性能来看，平衡孔板流量计属于高档流量计行列。</div>
<div>5:1量程比时，线性度可达±0.3％；</div>
<div>7:1量程比时，线性度可达±0.5％；</div>
<div>10:1量程比时，线性度可达±1.0％</div>
<div></div>
<div>二、直管段要求比孔板流量计要低</div>
<div>平衡流量传感器由于流场稳定，且压力恢复比孔板快两倍，大大所短了对直管段的要求其前后直管段一般为前3D后1D，最小可以小于0.5D，从而省去大量直管段，尤其是特殊昂贵的材料的管道。</div>
<div></div>
<div>三、减少永久压力损失</div>
<div>多孔对称的平衡设计，减少了紊流剪切力和涡流的形成，降低了动能的损失，在同样的测量工况下，与孔板相比减少了2.5倍的永久压力损失，从而节省了相当大的运行能量成本，是一种节能型仪表，值得大量推广。</div>
<div></div>
<div>四、耐脏污不易堵</div>
<div>多孔对称的平衡设计，减少了紊流剪切力和涡流的形成，从而大大降低了滞留死区的形成，保证脏污介质顺利通过多个孔，减小了流体孔被堵塞的机会。</div>
<div></div>
<div>五、可直接替换孔板流量计</div>
<div>其与孔板具有相同的使用方法和外形，因此可以直接进行替换，不需要任何配管的变化和相关仪表的更改，很适合全厂能源计量EMS改造中将孔板改为平衡流量计。</div>
<div></div>
<div>六、流量测量范围比孔板流量计要宽</div>
<div>根据试验结果，我们了解到：平衡孔板流量计的性能，使其流速可以从最小到音速；其最小雷诺数可低于200，最大雷诺数大于107；β值可选0.25～0.90。</div>
<p><a href="https://www.zhanfengdesign.com/1571/">孔板流量计与平衡孔板流量计的差别</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>节流孔板流量计由哪些部分组成</title>
		<link>https://www.zhanfengdesign.com/1572/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 09:33:55 +0000</pubDate>
				<category><![CDATA[孔板流量计技术文章]]></category>
		<category><![CDATA[技术文章]]></category>
		<category><![CDATA[孔板流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>差压式孔板流量计是一种将孔板和差压变送器 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1572/">节流孔板流量计由哪些部分组成</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>差压式孔板流量计是一种将孔板和差压变送器配套组成一体的流量计，结构简单、牢固、性能稳定可靠、价格低廉，使用寿命长，采用可靠性高的整体化孔板进行流量测定，可广泛应用于石油、炼化、化工、天然气、冶金、电力、制药等领域中，各种液体，气体、天然气及蒸汽流量的测量和计算。</div>
<div></div>
<div><a href="https://www.zhanfengdesign.com/kbllj/">节流孔板流量计</a>也称之为差压式流量计是由一次检测件(节流件)和二次装置(差压变送器和流量显示仪)组成广泛应用于气体，蒸汽和液体的流量测量。具有结构简单，维修方便，性能稳定，使用可靠等特点。</div>
<div></div>
<div>那么节流孔板流量计是由哪几部分组成的呢：</div>
<div></div>
<div>1.节流件：节流装置里的一种，他的优点是工作可靠、成本低。</div>
<div>节流件是在充满管道的流体流经管道内的一种流装置，流束将在节流处形成局部收缩，从而使流速增加，静压力降低，于是在节流件前后产生了静压力差。</div>
<div></div>
<div>2.法兰：又叫法兰凸缘盘或突缘。法兰是管子与管子之间相互连接的零件，用于管端之间的连接；也有用在设备进出口上的法兰，用于两个设备之间的连接，如减速机法兰。法兰连接或法兰接头，是指由法兰、垫片及螺栓三者相互连接作为一组组合密封结构的可拆连接。管道法兰系指管道装置中配管用的法兰，用在设备上系指设备的进出口法兰。法兰上有孔眼，螺栓使两法兰紧连。法兰间用衬垫密封。法兰分螺纹连接（丝扣连接）法兰、焊接法兰和卡夹法兰。法兰都是成对使用的，低压管道可以使用丝接法兰，四公斤以上压力的使用焊接法兰。两片法兰盘之间加上密封垫，然后用螺栓紧固。不同压力的法兰厚度不同，它们使用的螺栓也不同。水泵和阀门，在和管道连接时，这些器材设备的局部，也制成相对应的法兰形状，也称为法兰连接。凡是在两个平面周边使用螺栓连接同时封闭的连接零件，一般都称为“法兰”，如通风管道的连接，这一类零件可以称为“法兰类零件”。但是这种连接只是一个设备的局部，如法兰和水泵的连接，就不好把水泵叫“法兰类零件”。比较小型的如阀门等，可以叫“法兰类零件”。</div>
<div></div>
<div>3.紧固件：螺栓、螺柱、螺钉、螺母等。</div>
<div></div>
<div>4.密封件：密封件是防止流体或固体微粒从相邻结合面间泄漏以及防止外界杂质如灰尘与水分等侵入机器设备内部的零部件的材料或零件。分为丁腈胶、三元乙丙橡胶、氟橡胶、硅胶、氟硅橡胶、尼龙、聚氨酯、工程塑料等。</div>
<div></div>
<div>5.引压管：用于将设备和系统的内部压力值引到差压变送器上，通过流量显示仪转换成流量，信号变送到控制系统。</div>
<p><a href="https://www.zhanfengdesign.com/1572/">节流孔板流量计由哪些部分组成</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>节流孔板流量计用途</title>
		<link>https://www.zhanfengdesign.com/1573/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 09:33:38 +0000</pubDate>
				<category><![CDATA[孔板流量计技术文章]]></category>
		<category><![CDATA[技术文章]]></category>
		<category><![CDATA[孔板流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>用途、特点及适用范围 1、用途：节流孔板 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1573/">节流孔板流量计用途</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>用途、特点及适用范围</div>
<div></div>
<div>1、用途：<a href="https://www.zhanfengdesign.com/kbllj/">节流孔板流量计</a>由三部分组成：节流装置、差压变送器和流量积算仪。节流装置是直接安装于管道上的一次元件，差压变送器和积算仪属于二次元件。它主要用于对流经管道各种气体（纯净的或含粉尘的）、蒸汽（饱和或过热）和液体（导电或不导电；强腐蚀性；粘稠或含有微小颗粒脏污）流量的测量。可直接测量体积流量或质量流量。</div>
<div></div>
<div>2、差压式流量计（标准孔板）的使用条件、特点及适用范围</div>
<div></div>
<div>a、使用条件：</div>
<div>1)在测量段，流体必须充满圆管，并连续不断地流经节流装置；</div>
<div>2)流体在物理热力学上必须是均匀的单相流体；</div>
<div>3)节流装置所测流体必须是稳定流，或可看作是稳定的缓慢变化的流体，不适用于脉动流和临界流的测量；</div>
<div></div>
<div>b、特点及适用范围：</div>
<div>1）标准节流装置无须实流标定即可保证其测量精度。（在所有流量计中是唯一的）；</div>
<div>2）被测介质非常广泛，几乎可用于所有气体、蒸汽和液体的流量测量；</div>
<div>3）直径比β范围0.22~0.75，雷诺数ReD≥5000 管道直径DN50~1000mm，允许外推到5000mm。β=d/D，d—孔板开孔直径；D—管道实际内径</div>
<div>4）使用压力可高达32MPa，也可用于负压；</div>
<div>5）介质温度范围：-30℃～+650℃；</div>
<div>6）智能型差压式流量计采用智能差压变送器，可根据被测对象流量的变化，通过按键或通讯方式现场设定差压值（规定范围内），从而改变流量范围，使系统流量范围度大大拓宽；</div>
<div>7）无可动部件，机构安全可靠，使用、操作简单、易掌握，免维修；</div>
<div></div>
<div>根据中华人民共和国国家标准GB/T2624-93 和国际标准ISO5167-1 规定，节流装置适用的流量量程比为3（即最大与最小流量之比），在个别情况下允许量程比为4，如果量程比大于上述值，则在小流量时的测量误差较大</div>
<p><a href="https://www.zhanfengdesign.com/1573/">节流孔板流量计用途</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>多孔孔板流量计的安装要求</title>
		<link>https://www.zhanfengdesign.com/1574/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 09:33:19 +0000</pubDate>
				<category><![CDATA[孔板流量计技术文章]]></category>
		<category><![CDATA[技术文章]]></category>
		<category><![CDATA[孔板流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>多孔孔板流量计基本要求： 1．对于新设管 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1574/">多孔孔板流量计的安装要求</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>多孔孔板流量计基本要求：</div>
<div>1．对于新设管路系统，必须先经扫线后再安装标准孔板，以防管内杂物堵塞或损伤标准孔板。</div>
<div>2．安装前应仔细核对标准孔板的编号、位号、规格是否与管道情况、流量范围等参数相符。在取压口附近标有“+”的一端应与流体上游管段联接，标有“—”的一端应与流体下游管段联接。</div>
<div>3．标准孔板的中心线应当与管道中心线同轴。</div>
<div></div>
<div>二、<a href="https://www.zhanfengdesign.com/kbllj/">多孔孔板流量计</a>安装对管道的要求：</div>
<div>1．多孔孔板流量计安装时应配有一段测量管,至少保持前10DN、后5DN的等径直管段，以提高测量精度。</div>
<div>2．在多孔孔板流量计前后若需安装阀门，选闸阀且在运行中全开；调节阀则应在下游5DN之后的管路中。</div>
<div>3．引压管路的内径与管路长度和介质脏污程度有关，通常在45米以内用内径为8-12mm的管子。</div>
<div>4．测量液体流量时引压管水平段应在同一水平面内。若是在垂直管道上安装节流件，引压短管之间相距一定的距离（垂线方向），这对差压变送器的零点有影响，应通过“零点迁移”来校正。</div>
<div>5．引压管路应有牢固的支架托承，两根取压管路应尽可能互相靠近并远离热源或震动源，测量水蒸汽流量时，应用保温材料一同包扎，必须时（如气温0℃以下）加伴热管防止结冰。在测量脏污流量时，应附设隔离器或沉降器。</div>
<div>6．引压管路内必须始终保持单相流体状态。被测流体是气体时，引压管路（包括差压计的压力腔）内全部是气相；被测流体是液体时，引压管路内全部是液相，不能有气泡。为此应在引压管路的最低点装排水阀或在zui高点装排气阀，在新装或检修差压变送器时时应特别注意。</div>
<p><a href="https://www.zhanfengdesign.com/1574/">多孔孔板流量计的安装要求</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>多孔孔板流量计特点</title>
		<link>https://www.zhanfengdesign.com/1575/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 09:32:57 +0000</pubDate>
				<category><![CDATA[孔板流量计技术文章]]></category>
		<category><![CDATA[技术文章]]></category>
		<category><![CDATA[孔板流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>1.测量精度高 由于平衡流量传感器具有多 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1575/">多孔孔板流量计特点</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>1.测量精度高</div>
<div>由于平衡流量传感器具有多孔结构的特点，能对流场进行平衡,降低涡流、振动和信号噪声，流场稳定性大大的提高，表体采用特制的精密管道和专用取压装置，使精确度比传统节流装置提升了5-10倍。</div>
<div>经过实流标定，传感器精确度可达±0.3%、±0.5%，适用于贸易计量场合。</div>
<div>几何尺寸检验，传感器精确度可达±0.5%、±1.0%，适用于过程控制场合。</div>
<div><a href="https://www.zhanfengdesign.com/kbllj/">多孔孔板流量计</a>加工重复性极高，与传统节流装置一样，在实流标定数据基础上，可以实现几何尺寸检定。</div>
<div></div>
<div>2.直管段要求低</div>
<div>平衡流量传感器能将流场平衡，调整稳定，且压力恢复比传统节流装置快两倍，大大缩短了对直管段的要求。大多数情况下直管段可以小至0.5D~2D，尤其对于特殊或昂贵的管道，采用多孔孔板流量计可以省去大量的直管段。</div>
<div><img decoding="async" style="width: 602px; height: 360px;" src="/uploads/allimg/210625/1-210625093531545.jpg" alt="" /></div>
<div></div>
<div>3.永久压力损失低</div>
<div>多孔孔板流量计的对称平衡设计，减少了涡流的形成和紊流摩擦，降低了动能的损失，在同样的工况下，与传统节流装置比较，压力损失较少了70%，接近文丘里管，从而节省了相当大的运行成本，值得大量推广。</div>
<div></div>
<div>4.量程比宽</div>
<div>与传统节流装置相比，多孔孔板流量计极大提高了测量量程比。研究结果显示，雷诺数大于50000时，选择合适的孔径参数，平衡流量计无上限，根据工业测量实际应用的需要，常规测量量程比为10:1，选择合适的参数可以做道30:1或更高。</div>
<div></div>
<div>5.重复性和长期的稳定性好</div>
<div>平衡流量传感器能将流场平衡稳定，使重复性大大提高，可达到±0.1%。</div>
<div>多孔孔板流量计多个流通孔分散受力，无锐角磨损，其β值长期保持不变，长期稳定性非常好；整个仪表无可动部件，使用寿命比传统节流装置延长了5-10倍。</div>
<div></div>
<div>6.耐脏污不宜堵</div>
<div>多孔对称的平衡设计，减少了紊流剪切力和涡流的形成，从而大大降低了死区的形成，保证脏污介质顺利通过多个孔，减少了流体孔被堵塞的机会。</div>
<div><img decoding="async" style="width: 371px; height: 270px;" src="/uploads/allimg/210625/1-2106250935525K.jpg" alt="" /></div>
<div></div>
<div>7.测量范围宽</div>
<div>根据实验结果。我们知道：多孔孔板流量计的性能，使其流速可以从最小到音速，其最小雷诺数可低于200，最大雷诺数大于107；β值可选0.25~0.9。</div>
<div></div>
<div>8.适用范围</div>
<div>多孔孔板流量计的工作温度，压力取决于管道和法兰的材质和等级，工作温度最高可达到850℃，42MPa。</div>
<div>适合极低温流体LNG，液空气，液氮，液氧，液氩，液化乙烯，液氢，液氯等，能有效防止气化，测量效果最佳。</div>
<div>多孔孔板流量计可以测量汽液两相、浆料、甚至固体颗粒测量，还可以测量双向流。</div>
<div>多孔孔板流量计左右完全对称，因此可以十分方便地测量双向流。</div>
<div>多孔孔板流量计的安装方式及介质流向</div>
<div><img decoding="async" style="width: 552px; height: 527px;" src="/uploads/allimg/210625/1-21062509360bT.jpg" alt="" /></div>
<div></div>
<div>9.平衡阀与三阀组的安装要求</div>
<div>平衡阀或三阀组的作用</div>
<div>⑴调整差压变送器的零点</div>
<div>⑵防止差压变送器的正负、压室过压</div>
<div></div>
<div>10.压变送器的安装要求</div>
<div>⑴将多孔孔板流量计正压则引压管导入三阀组接至差压变送器的正压室，将多孔孔板流量计负压侧引压管导入三阀组接至差压变送器的负压室</div>
<div></div>
<div>⑵差压变送器在工艺管道上的安装位置与被测介质有关,为了获得较好的安装效果，应注意考虑下面情况A 防止变送器与腐蚀性或过热的被测介质直接接触B 防止渣滓在引压管内沉积，堵塞C正负压两侧引压管的长度应尽量相同D 正负压两侧引压管内的液柱压头应保持平衡E 引压管安装在温度梯度和温度波动最小的地方</div>
<div></div>
<div>⑶测量液体流量时，差压变送器应安装在被测管道的旁边或下面，以便气泡排入管道中</div>
<div></div>
<div>⑷测量气体流量时，差压变送器应安装在被测管道的旁边或上面，以便积聚的液体容易流入管道中</div>
<div></div>
<div>⑸测量蒸汽流量时，差压变送器应安装在被测管道的下面，以便冷凝水能充满在引压管中。应特别注意，测量蒸汽或其它高温介质时，要防止差压变送器接触介质的温度超过变送器使用的极限温度。</div>
<div><img decoding="async" style="width: 599px; height: 344px;" src="/uploads/allimg/210625/1-210625093629403.jpg" alt="" /></div>
<div></div>
<div>11.温度、压力变送器的安装要求</div>
<div>1、测量过热蒸汽介质时，必须要加一体化温度变送器和压力变送器，进行动态补偿.测量饱和蒸汽介质时，必须要加压力变送器，进行动态补偿。</div>
<div></div>
<div>2、测量天然气、煤气介质时，必须要加压力变送器进行动态补偿，而且要用加安全栅及防爆装置的变送器。</div>
<div></div>
<div>3、测量热水介质，需要有热量显示时，必须要加温度一体化变送器，否则可省去温度一体化变送器。</div>
<div></div>
<div>4、温度一体化变送器安装在被测管道上，必须再多孔孔板流量计前5D 只管段或或后2D 直管段以外温度探头顶端应插入超过管径二分之一，以保证测量精度。</div>
<div></div>
<div>5、差压变送器的压力取压点，必须在平衡流量计前5D 直管观段或后2D 直管段以外，其间安装开关阀。对于温度一体化变送器和压力变送器的安装，一体化孔板流量计原则上只要符合常规的安装规范就可以满足本系统的要求，其具体的安装要求可分别参见各自的安装说明书。</div>
<p><a href="https://www.zhanfengdesign.com/1575/">多孔孔板流量计特点</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>影响液体孔板流量计计量的因素</title>
		<link>https://www.zhanfengdesign.com/1576/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 09:32:35 +0000</pubDate>
				<category><![CDATA[孔板流量计技术文章]]></category>
		<category><![CDATA[技术文章]]></category>
		<category><![CDATA[孔板流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>液体孔板流量计是将标准孔板与多参数差压变 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1576/">影响液体孔板流量计计量的因素</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>液体孔板流量计是将标准孔板与多参数差压变送器(或差压变送器、温度变送器及压力变送器)配套组成的高量程比差压流量装置，可测量气体、蒸汽、液体及天然气的流量，广泛应用于石油、化工、冶金、电力、供热、供水等领域的过程控制和测量。标准孔板是由机械加工获得的一块圆形穿孔的薄板，它的节流孔圆筒形柱面与孔板上游端面垂直，其边缘是尖锐的，孔板厚与孔板直径比是比较小的。孔板在测量管内的部分应该是圆的并与测量管轴线同轴，孔板的两端面应始终是平整的和平行的。</div>
<div></div>
<div>影响<a href="https://www.zhanfengdesign.com/kbllj/">液体孔板流量计</a>测量精度的因素主要有以下六大方面：</div>
<div></div>
<div>一、被测流体特性影响：</div>
<div>由于天然气本身的性质，会随着外界环境温度的变化而发生复杂的变化，从而影响流量计的测量精度。对于天然气的测量，必须首先确定天然气的工作温度和压力，因为外界温度的变化，会使天然气本身的压力和温度也发生变化，都有可能造成过大的密度变化和压缩系数变化。低密度气体对某些测量方法呈现困难，此时就要改变所选择的测量方法，或者作温度和压力修正，以保证测量准确度。</div>
<div></div>
<div>二、仪表性能的影响：</div>
<div>液体孔板流量计本身引起的误差原因主要有：孔板入口直角锐利度；管径尺寸与计算不符；孔板厚度误差；节流件附件产生台阶、偏心；孔板流量计孔板上游端面平度；环室尺寸产生台阶、偏心；取压位置；焊接、焊缝突出；取压孔加工不规范或堵塞；节流件不同轴度等等。这些因素都有可能影响孔板的重复性，重复性是由仪器本身原理与制造质量所决定，它在过程控制应用中是重要的指标。而精确度除取决于重复性外，尚与量值标定系统有关。在实际应用中，仪表优良的重复性被许多因素包括流体粘度、密度等变化所干扰，都会影响测量精度。若仪表输出特性是非线性的，则这种影响更为突出。</div>
<div></div>
<div>三、流量计安装的影响：</div>
<div>管线布置的偏离造成的安装误差是普遍性的，其产生的主要原因是现场不能满足直管段要求的长度。</div>
<div></div>
<div>四、环境条件方面的影响：</div>
<div>虽然流量计安装能正常使用了，但因所使用环境条件与预期的情况发生了改变，使仪表的一些性能参数和硬件方面也随之发生了改变，从而会改变流量计测量结果。液体孔板流量计易于偏离标准的原因在于仪表本身的工作原理与结构特点，仪器自身误差是制造时产生的，安装和使用误差则是在安装时或长期使用中由于流体介质腐蚀、磨损、沾污等造成的。因此，应严格按技术要求安装流量计量系统，消除安装误差。</div>
<div></div>
<div>五、气流中的脉动流：</div>
<div>管道中由于气体的流速和压力发生突然变化，造成脉动流，它能引起差压的波动，而节流装置的流量计算公式是以兰孔板的稳定流动为基础的，当测量点有脉动现象时，稳定原理不能成立，从而影响测量精度，产生计量误差。因此，为了保证气体计量精度，必须抑制脉动流。常用的措施有：</div>
<div>(1)在满足计量能力的条件下，应选择内径较小的测量管，提高差压和孔径比；</div>
<div>(2)采用短引压管线，减少管线中的阻力件，并使上下游管线长度相等，减少系统中产生谐振和压力脉动振幅增加；</div>
<div>(3)从管线中消除游离液体，管线中的积液引起的脉动可采用自动清管系统或低处安装分液器来处理。</div>
<div><img alt="src=/uploads/allimg/210629/1-210629105Q6401.jpg" /></div>
<div></div>
<div>六、人为计量误差：</div>
<div>加强计量管理，提高操作人员技术素质，积极引进吸收国外先进的天然气计量技术。</div>
<div></div>
<div>由于影响液体孔板流量计测量精度的根本原因是节流装置的几何形状和流动动态是否偏离设计标准。因此在使用过程中必须定期做好系统的校检、维护工作，对于实际使用中的压力、温度、流量等工况参数的变化，应进行及时修正。可采用全补偿的流量计算机的积算方案，以减少计量误差，确保计量精度。</div>
<p><a href="https://www.zhanfengdesign.com/1576/">影响液体孔板流量计计量的因素</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>智能孔板流量计参数设置</title>
		<link>https://www.zhanfengdesign.com/1578/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 09:31:52 +0000</pubDate>
				<category><![CDATA[孔板流量计技术文章]]></category>
		<category><![CDATA[技术文章]]></category>
		<category><![CDATA[孔板流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>为了确保您的智能孔板流量计在zui佳参数 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1578/">智能孔板流量计参数设置</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>为了确保您的<a href="https://www.zhanfengdesign.com/kbllj/">智能孔板流量计</a>在zui佳参数范围内保持正常运行，我们根据我们多年的经验以及客户的意见收集智能孔板流量计使用，设置和维护提示。</div>
<div></div>
<div>1、选择与所有预期过程流体和清洁/冲洗剂化学兼容的磁流量传感器材料。注意蒸汽输出条件，要求仪表额定温度更高，真空度更高。</div>
<div></div>
<div>2、正确定位磁力计以保持仪表充满，避免两相条件。如果可能，向上流过流量计。</div>
<div></div>
<div>3、使用推荐的上游和下游管道长度以确保适当的流体调节，以获得zui佳的流量测量结果。如果空间要求不允许zui小直径，请咨询制造商。</div>
<div></div>
<div>4、如果使用绝缘，请勿盖住线圈外壳或电子元件，因为这些组件可能会过热而失效。</div>
<div></div>
<div>5、适当调整智能孔板流量计的尺寸，以在整个工艺流程范围内实现zui佳的流量测量性能。大多数智能孔板流量计在选择时可以很好地匹配过程管道尺寸，但对于以低流速运行的过程，添加减速器以适应较小的磁传感器将提高测量精度（通过增加通过传感器的流体速度） 。</div>
<div></div>
<div>6、将变送器的接线与其自身导管中的磁传感器隔离。不要在与任何其他设备接线共用的导管中运行Mag接线。任何电气干扰都可能导致测量偏移。</div>
<div></div>
<div>7、避免剥离磁性仪表接线过多的绝缘层。任何未被编织屏蔽覆盖的裸露电线都会对测量电路产生额外的电子干扰。</div>
<div></div>
<div>8、通过使用接地带，接地环，衬里保护器或专用接地电极，确保孔板流量计电子元件接地到过程流体（除了接地）。</div>
<div></div>
<div>9、确认流量传感器的校准常数在电子设备中正确反映。对于能够以多个频率驱动磁线圈的传感器，每个线圈驱动频率应该有一个weiyi的校准编号。</div>
<div></div>
<div>10、如果使用交流供电仪表，或在脉冲直流电表上以高线圈驱动频率运行，则执行零校准。</div>
<div></div>
<div>11、如果制造商要求，确定电路健康监测诊断测试值（也称为仪表校验）的字段基线。</div>
<p><a href="https://www.zhanfengdesign.com/1578/">智能孔板流量计参数设置</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>环室孔板流量计用途</title>
		<link>https://www.zhanfengdesign.com/1580/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 09:31:28 +0000</pubDate>
				<category><![CDATA[孔板流量计技术文章]]></category>
		<category><![CDATA[技术文章]]></category>
		<category><![CDATA[孔板流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>环室孔板是属于圆形孔板一类的，主要作用于 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1580/">环室孔板流量计用途</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>环室孔板是属于圆形孔板一类的，主要作用于比较干湿的空气流量测量，效果非常好。在低温环境下，也可以用此类孔板去测量流量，因为其环室结构可以避免内部元件受到低温环境的影响。而且，现在增加了整流器，<a href="https://www.zhanfengdesign.com/kbllj/">环室孔板流量计</a>可以承受耐温zui低到零下50度。</div>
<div>环室孔板流量计是孔板流量计取压方式的一种，也可以叫做环室取压孔板流量计，这种取压方式主要针对于高温高压的流体介质，zui常用的就是蒸汽介质测量。节流件和法兰之间多了一层环室，介质在经过环室循环后进入取压口，使zui终的得出的差压值更加稳定，流量值更加精确。</div>
<div>环室孔板流量计技术参数</div>
<div>1. 公称直径： 15 mm≤DN≤2000mm</div>
<div>2. 公称压力：PN≤25MPa</div>
<div>3. 工作温度：－50℃≤t≤850℃</div>
<div>4. 量程比：1:5， 1:10</div>
<div>5. 精度：0.5级，1.0级</div>
<div>环室孔板流量计的用途及特点</div>
<div>环室孔板流量计适用于各种流体介质（气体、蒸汽、液体）的测量，例如饱和蒸汽、过热蒸汽、压缩空气、各种煤气、废气、冷却水、重油、渣油、燃料油、冷凝液、各种化工溶液等，</div>
<div>环室孔板流量计的特点：</div>
<div>1、测量含有固体微粒的液体或气体；</div>
<div>2、环室孔板流量计在恶劣条件下流出系数稳定，精度高，可靠性好；</div>
<div>3、压力损失小，功耗低；</div>
<div>4、环室孔板流量计无需长直管段，可在恶劣的管道条件下工作；</div>
<div>5、环室孔板流量计适用于饱和蒸汽、压缩空气、煤气、燃炉废气、冷却水、冷凝液、和各种腐蚀性化工溶液以及各种流体介质的测量。</div>
<p><a href="https://www.zhanfengdesign.com/1580/">环室孔板流量计用途</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>高压孔板流量计结构图</title>
		<link>https://www.zhanfengdesign.com/1581/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 09:31:07 +0000</pubDate>
				<category><![CDATA[孔板流量计技术文章]]></category>
		<category><![CDATA[技术文章]]></category>
		<category><![CDATA[孔板流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>高压孔板流量计是将标准孔板与多参数差压变 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1581/">高压孔板流量计结构图</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>高压孔板流量计是将标准孔板与多参数差压变送器（或差压变送器、温度变送器及压力变送器）配套组成的高量程比差压流量装置，可测量气体、蒸汽、液体及引的流量，广泛应用于石油、化工、冶金、电力、供热、供水等领域的过程控制和测量。节流装置又称为差压式流量计，是由一次检测件（节流件）和二次装置（差压变送器和流量显示仪）组成广泛应用于气体。蒸汽和液体的流量测量。具有结构简单，维修方便，性能稳定。在已知有关参数的条件下，根据流动连续性原理和伯努利方程可以推导出差压与流量之间的关系而求得流量。</div>
<div></div>
<div>基本结构</div>
<div>1.节流件：标准孔板、标准喷嘴、长径喷嘴、1／4圆孔板、双重孔板、偏心孔板、圆缺孔板、锥形入口孔板等</div>
<div>2.取压装置：环室、取压法兰、夹持环、导压管等</div>
<div>3.连接法兰（家标准、各种标准及其它设计部门的法兰）　、紧固件。</div>
<div>4.测量管</div>
<div>5.<a href="https://www.zhanfengdesign.com/kbllj/">孔板流量计</a>结构图：</div>
<div><img decoding="async" style="width: 250px; height: 150px;" src="/uploads/allimg/210629/1-210629110322K2.jpg" alt="" /></div>
<div>环室取压标准孔板</div>
<div>PN≤2.5</div>
<div></div>
<div><img decoding="async" style="width: 250px; height: 150px;" src="/uploads/allimg/210629/1-210629110333U2.jpg" alt="" /></div>
<div>环室取压标准孔板</div>
<div>4.0≤PN≤6.4</div>
<div></div>
<div><img decoding="async" style="width: 250px; height: 150px;" src="/uploads/allimg/210629/1-210629110344O6.jpg" alt="" /></div>
<div>钻孔取压标准孔板</div>
<div>PN≤2.5</div>
<div></div>
<div><img decoding="async" style="width: 250px; height: 150px;" src="/uploads/allimg/210629/1-210629110359221.jpg" alt="" /></div>
<div>紧固式八槽孔板</div>
<div>PN≤10</div>
<div></div>
<div><img decoding="async" style="width: 250px; height: 150px;" src="/uploads/allimg/210629/1-210629110412132.jpg" alt="" /></div>
<div>焊接式八槽孔板</div>
<div>PN≤10</div>
<div></div>
<div><img decoding="async" style="width: 250px; height: 150px;" src="/uploads/allimg/210629/1-210629110425307.jpg" alt="" /></div>
<div>径距取压标准孔板</div>
<div>PN≤2.5</div>
<div></div>
<div><img decoding="async" style="width: 250px; height: 150px;" src="/uploads/allimg/210629/1-2106291104351F.jpg" alt="" /></div>
<div>压透镜垫孔板</div>
<div>PN22，32</div>
<div></div>
<div><img decoding="async" style="width: 250px; height: 150px;" src="/uploads/allimg/210629/1-210629110445111.jpg" alt="" /></div>
<div>法兰取压标准孔板</div>
<div>4.0≤PN≤6.4</div>
<p><a href="https://www.zhanfengdesign.com/1581/">高压孔板流量计结构图</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>气体孔板流量计的校准</title>
		<link>https://www.zhanfengdesign.com/1583/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 09:30:24 +0000</pubDate>
				<category><![CDATA[孔板流量计技术文章]]></category>
		<category><![CDATA[技术文章]]></category>
		<category><![CDATA[孔板流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>气体孔板流量计的校准是一项非常重要的工作 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1583/">气体孔板流量计的校准</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>气体孔板流量计的校准是一项非常重要的工作，很多用户都关心这个问题。</div>
<div></div>
<div>今天就就提说说<a href="https://www.zhanfengdesign.com/kbllj/">气体孔板流量计</a>该怎样正确的校准的问题</div>
<div>(1)投运前打开“三阀组”中的平衡阀，关严正负取压管路上的阀门，检查、校正差压变送器的零点，一定注意“零点”是在正负压力腔完全等压(即差压等于0)时，核查调整差压变送器。</div>
<div></div>
<div>(2)在流体流动状态下即使全开“平衡阀”，只要不关严正负取压管路上的取压阀门，也不能核查零点。因为平衡阀本身有阻力，不能完全平衡正负压力腔的压力，即达不到“零差压”状态。</div>
<div></div>
<div>(3)测量脏污流体流量时，一定要配置沉降器或隔离器。注意导压流体的进口、出口及排污口的位置如何合理选择，以达到排污目的。</div>
<div></div>
<div>(4)测量腐蚀性流体流量时，一定要选用合适的隔离器，根据介质比重选用合适的隔离液，并注意合理选择隔离液与被测流体的入口。</div>
<div></div>
<div>(5)孔板的设计参数是否与实际参数相符，直接关系到测量精度。标准孔板投入使用时，测得的参数如果处于设计参数的范围内，测量精度一般不会超过设计计算精度；但是如果测得的参数远离设计参数范围(假定标准孔板及差压变送器选型、制造、安装均符合要求)则有可能是提供的设计参数有误，应更改设计参数，重新设计计算标准孔板。</div>
<div></div>
<div>气体孔板流量计维护注意事项</div>
<div>(1).日常维护工作主要是清除沉降器或隔离器内的积垢，定期从排污口处放掉，在被测介质是高温高压腐蚀或有毒流体时，清除时要注意安全。</div>
<div></div>
<div>(2).差压变送器的零点有时发生漂移，影响测量精度(特别是流量小、差压接近下限值时)，要经常校对零点。质量好的差压变送器可根据经验延长校零周期至1年，而质量差的则可能数天校一次零点，所以我们建议配用质量好的差压变送器，减轻日常维护工作量。</div>
<p><a href="https://www.zhanfengdesign.com/1583/">气体孔板流量计的校准</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>气体孔板流量计日常维护</title>
		<link>https://www.zhanfengdesign.com/1584/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 09:29:58 +0000</pubDate>
				<category><![CDATA[孔板流量计技术文章]]></category>
		<category><![CDATA[技术文章]]></category>
		<category><![CDATA[孔板流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>(1)仪表检修后投用，对于测量气体的孔板 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1584/">气体孔板流量计日常维护</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>(1)仪表检修后投用，对于测量气体的孔板流量计，要排掉引压管、差压变送器内积液；对于测量油品的，要排掉测量系统内的水、气体，并使得介质充满管道；同时检查各附属接头、阀门、卡套有无泄露，零点是否漂移。</div>
<div></div>
<div>(2)孔板差压变送器、现场接线箱等部位定期做防水检查，特别是南方雨季、台风来临前，防止接线端子、电路板进水引起仪表故障或出现波动，还有对差压变送器定期检查零点是否漂移。</div>
<div></div>
<div>(3)重要<a href="https://www.zhanfengdesign.com/kbllj/">气体孔板流量计</a>，配合工艺做好排液、排气等工作，如分馏塔回流带水，仪表专业要在工艺操作稳定后及时排液、排气，校验流量是否符合当前物料平衡要求。</div>
<div></div>
<div>(4)针对引压管经常带水或测量介质带腐蚀性的情况，仪表专业可通过打压泵给高低压引压管平衡灌隔离液(选择合适比重的隔离液)的方式，避免因引压管带水导致流量计测量或介质腐蚀变送器。对需要灌隔离液的流量计，要控制好打压压力，并注意排除气泡，调校好仪表零位，并按规范步骤投用仪表。</div>
<div></div>
<div>(5)加强仪表维护人员技能培训，在投用过程中要避免变送器单向受压、或变送器泄漏，不能让导压管内凝结水或隔离液流失；不可使变送器单受热，对于蒸汽，待导压管充满凝结水后方可启动变送器。</div>
<div></div>
<div>(6)在冬季，特别是在北方，对于凝点比较低的介质，仪表专业与工艺专业要配合做好引压管线保温、伴热工作，避免因天气温度过低导致介质在引压管处冷凝，引起仪表测量不准。</div>
<div></div>
<div>(7)停工检修时，蒸汽吹扫要提前隔离变送器避免高温损坏，对长期使用或经常波动偏差的孔板进行下线检查，检查直管段堵塞情况、孔板直角入口边缘光洁度和锐利度、孔板表面垂直度、平行度等是否符合要求，如有超出设计标准，要及时对孔板进行修正或更换。</div>
<div></div>
<div>(8)定期检查孔板设计参数与实际参数是否一致，使得气体孔板流量计的测量范围满足精度要求，如因生产条件变化导致孔板测量不准，仪表维护人员不可随意更改变送器参数。</div>
<div></div>
<div>结束语：在日常生产操作过程中，气体孔板流量计出现异常或偏差时，仪表维护人员要及时排除是否由工艺工况改变造成，然后再进一步排除是否由差压变送器、三阀组或孔板本身引起等故障，及时排查出产生偏差的原因并解决，为生产操作提供可靠性参考，这就要求维护人员对本装置工艺流程及介质特性有一个相对深入的了解，为快速判断仪表故障及与工艺操作员有效沟通奠定基础。</div>
<p><a href="https://www.zhanfengdesign.com/1584/">气体孔板流量计日常维护</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>dn50孔板流量计的量程比如何确定</title>
		<link>https://www.zhanfengdesign.com/1585/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 09:29:40 +0000</pubDate>
				<category><![CDATA[孔板流量计技术文章]]></category>
		<category><![CDATA[技术文章]]></category>
		<category><![CDATA[孔板流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>dn50孔板流量计是工业仪表中历史最为悠 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1585/">dn50孔板流量计的量程比如何确定</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>dn50孔板流量计是工业仪表中历史最为悠久，应用最为广泛的流量测量仪表，其结构简单，制作方便，安装，使用，维护等简单易懂。可靠性极高。只需按照国家标准进行计算，加工，基本无需实流标定，就可直接获得较高的测量精度。近年来流量计的种类愈加繁多，但是<a href="https://www.zhanfengdesign.com/kbllj/">dn50孔板流量计</a>仍能保持一定的市场份额。可表明dn50孔板流量计的不可替代性。dn50孔板流量计测得初始值为差压值，经开方后与流体流量成正比。dn50孔板流量计流量测量范围受差压值，流出系数，雷诺数等多方因素的影响，使得dn50孔板流量计量程比很难有所增加，以下就简单分析dn50孔板流量计量程比受限的主要原因。</div>
<div><img decoding="async" style="width: 450px; height: 391px;" src="/uploads/allimg/210701/1-210F1095F1W9.jpg" alt="" /></div>
<div>dn50孔板流量计量程比多为5:1，最多不超过10:1，其制约因素第一个就是差压变送器的量程。差压变送器是dn50孔板流量计最为精密的组成部件。差压变送器的量程以及测量精度直接决定了dn50孔板流量计的的测量精度以及测量范围。孔板流量计算公式中，差压值与流量的平方是正比关系。由此可见若使用流量为满量程的30%时，差压值处于差压变送器满度量程的9%。若用用流量为满度流量的20%时，则差压值差压差压变送器满度量程的4%。根据gb/t1624-93中不确定计算方式可知当现场使用流量小于满度流量的10%时，不确定度过大。因此厂家建议dn50孔板流量计量程比不宜超过10:1；第二个制约因素为流出系数的制约。现有的孔板流量计算公式中将流出系数作为常数来对待，但是在一定安装条件下，流出系数是随着雷诺数的变化而变化的，因此在实际制作过程中常见一般会增大孔板的差压值和提高流量计的下限值来降低流出系数对dn50孔板流量计测量的影响。该方式使得dn50孔板流量计的量程比更难有所增加。其三为可膨胀系数的制约。膨胀系数是对流体经过节流件由于密度变化引起流出系数变化的修正。常用流量条件下，膨胀系数接近于1，若现场使用流量偏离常用流量过多，会引起附加误差。该点也是限制dn50孔板流量计量程比的主要原因。</div>
<p><a href="https://www.zhanfengdesign.com/1585/">dn50孔板流量计的量程比如何确定</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>蒸汽孔板流量计安装要求</title>
		<link>https://www.zhanfengdesign.com/1428/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 09:24:53 +0000</pubDate>
				<category><![CDATA[孔板流量计技术文章]]></category>
		<category><![CDATA[技术文章]]></category>
		<category><![CDATA[孔板流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>对于仪表来说，如果仪表安装的不够规范，轻 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1428/">蒸汽孔板流量计安装要求</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>对于仪表来说，如果仪表安装的不够规范，轻则引起测量不准、故障率高、维护量加大等问题，重则有可能引起非计划停车，甚至引发安全事故。下面，仪控君就为大家整理了<a href="https://www.zhanfengdesign.com/kbllj/">蒸汽孔板流量计</a>安装时会出现的各种问题和注意事项，希望能够对大家有所帮助。</div>
<div></div>
<div><span style="color: #ff0000;"><strong>常见蒸汽孔板流量计安装错误</strong></span></div>
<div>1.孔板前后直管段不符合要求</div>
<div>孔板前后直管段的作用就是为了保证管道内流体的流动稳定，但由于工艺管道上常有拐弯、分叉、汇合等阻力件出现，使流体稳定变为扰动，从而导致测量误差。消除方法是按照前后管道要求，合理设计节流装置的安装位置。</div>
<div></div>
<div>2.孔板上下游面受损或孔板法兰垫片凸出管道内</div>
<div>在运输孔板或施工人员安装孔板过程中，容易造成上下游面受损或法兰垫片凸出管道内，从而导致测量误差。消除方法是提高施工人员的技术素质和责任心。施工人员在安装孔板前应仔细检查孔板片，若发现孔板上下游面受损，应及时更换；在安装孔板过程中应避免损坏孔板片；安装法兰垫片时，要使法兰垫片中心线和管道中心线一致。</div>
<div></div>
<div>3.孔板上下游面反装</div>
<div>安装前，应正确辨认管道内介质流向及孔板方向，否则将导致测量值偏低。这是因为施工人员的粗心所致，消除方法就是在安装孔板时，使孔板上标有“+”的面处在流向的上游侧。</div>
<div></div>
<div>4、不同孔板装错位置</div>
<div>这种情况一般在试车阶段特别容易出现。在试车阶段，各工艺管道需要多次吹扫，频繁拆装孔板。若孔板尺寸一样，稍不注意就会出现差错，调换孔板即可恢复正常。</div>
<div>由此可见为了让仪表发挥最大功能和作用，正确选型是首要条件，正确安装是决定性因素。</div>
<div></div>
<div><span style="color: #ff0000;"><strong>蒸汽孔板流量计安装前注意事项</strong></span></div>
<div>1.仪表安装前，工艺管道应进行吹扫，防止管道中滞留的铁磁性物质附着在仪表里，影响仪表的性能，甚至会损坏仪表。如果不可避免，应在仪表的入口安装磁过滤器。仪表本身不参加投产前的气扫，以免损坏仪表。</div>
<div></div>
<div>2.仪表在安装到工艺管道之前，应检查其有无损坏。</div>
<div></div>
<div>3.仪表的安装形式分为垂直安装和水平安装，如果是垂直安装形式，应保证仪表的中心垂线与铅垂线夹角小于2°；如果是水平安装，应保证仪表的水平中心线与水平线夹角小于2°。</div>
<div></div>
<div>4.仪表的上下游管道应与仪表的口径相同，连接法兰或螺纹应与仪表的法兰和螺纹匹配，仪表上游直管段长度应保证至少是仪表公称口径的5倍，下游直管段长度大于等于250mm。</div>
<div></div>
<div>5.由于仪表是通过磁耦合传递信号的，所以为了保证仪表的性能，安装周围至少250px处，不允许有铁磁性物质存在。</div>
<div></div>
<div>6.测量气体的仪表，是在特定压力下校准的，如果气体在仪表的出口直接排放到大气，将会在 浮子处产生气压降，并引起数据失真。如果是这样的工况条件，应在仪表的出口安装一个阀门。</div>
<div></div>
<div>7.安装在管道中的仪表不应受到应力的作用，仪表的出入口应有合适的管道支撑，可以使仪表处于最小应力状态。</div>
<div></div>
<div>8.安装PTFE（聚四氟乙烯）衬里的仪表时，要特别小心。由于在压力的作用下，PTFE会变形，所以法兰螺母不要随意拧得过紧。</div>
<div></div>
<div>9.带有液晶显示的仪表，安装时要尽量避免阳光直射显示器，降低液晶使用寿命。</div>
<div></div>
<div>10.低温介质测量时，需选夹套型。</div>
<div></div>
<div><span style="color: #ff0000;"><strong>蒸汽孔板流量计安装过程中的注意事项</strong></span></div>
<div>1.仪表开孔应避免在成型管道上开孔。</div>
<div></div>
<div>2.注意流量计前后直管段长度。</div>
<div></div>
<div>3.如有接地要求的电磁、质量等流量计，应按说明进行接地。</div>
<div></div>
<div>4.工艺管道焊接时，接地线应避开仪表本体，防止接地电流流经仪表本体入地，损坏仪表。</div>
<div></div>
<div>5.工艺焊接时，避免接地电流流经单、双法兰仪表的毛细导压管。</div>
<div></div>
<div>6.中、高压引压管能采用氩弧焊或承插焊的，应采用氩弧焊或承插焊。风速&gt;2m/s，应有防风措施，否则应采用药皮焊丝，风速&gt;8m/s，必须有防风措施，否则应停止施焊。</div>
<div></div>
<div>7.注意流量计节流装置取压口的安装方向。</div>
<div></div>
<div>8.不锈钢引压管严禁热煨；严禁将引压管煨扁。</div>
<div></div>
<div>9.仪表引压管、风管、穿线管的安装位置，应避免将来妨碍工艺生产操作，应避开高温腐蚀场所，应固定牢固；从上引下的穿线管，其最低引线端应低于所接仪表的接线进口端；穿线管最低端应增加滴水三通；靠近仪表侧宜增加Y型或锥形防爆密封接头；仪表主风线最低处应加排凝（污）阀。</div>
<div></div>
<div>10.仪表使用的铜垫片，如无退火处理，使用前应退火，并注意各种材质垫片的许用温度、介质和压力等条件。</div>
<div></div>
<div>11.现场仪表接线箱内，不同接地系统的接地不能混接，所有仪表的屏蔽线应单独连接上下屏蔽层，严禁拧在一起连接上下屏蔽。</div>
<div></div>
<div>12.仪表处于不易观察、检修位置时，改变位置或加装平台。</div>
<div></div>
<div>13.仪表线中间严禁接头，并做好隐蔽记录，补偿导线接头应采用焊接或压接。</div>
<p><a href="https://www.zhanfengdesign.com/1428/">蒸汽孔板流量计安装要求</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>蒸汽孔板流量计安装图</title>
		<link>https://www.zhanfengdesign.com/1432/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 09:24:10 +0000</pubDate>
				<category><![CDATA[孔板流量计技术文章]]></category>
		<category><![CDATA[技术文章]]></category>
		<category><![CDATA[孔板流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>作为厂家经常遇到到客户打电话反馈孔板流量 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1432/">蒸汽孔板流量计安装图</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>作为厂家经常遇到到客户打电话反馈孔板流量计怎样安装、有没有安装图、正确的安装方式怎样、有没有图文结合简单施工图等等之类的话题，有时讲了一遍、二遍还是不懂。但是作为客户也不能完全怪他们，说明书讲的比较抽象，客户要的就是一看就懂的安装效果图，针对这些问题小编通过图片为大家讲解正确的安装方式应是怎样的。</div>
<div><img decoding="async" style="width: 600px; height: 334px;" src="/uploads/allimg/210330/1-21033016362cS.jpg" alt="" /></div>
<div>孔板流量计效果图</div>
<div></div>
<div>对于新设管路系统，必须先经扫线后再安装<a href="https://www.zhanfengdesign.com/kbllj/">标准孔板流量计</a>，以防管内杂物堵塞或损伤标准孔板。标准孔板的中心线应当与管道中心线同轴。</div>
<div><img decoding="async" style="width: 600px; height: 399px;" src="/uploads/allimg/210330/1-210330163642P5.jpg" alt="" /></div>
<div>孔板流量计安装效果图</div>
<div></div>
<div>正确的孔板流量计效果图孔板流量计安装时应配有一段测量管,至少保持前10DN、后5DN的等径直管段，以提高测量精度在孔板流量计前后若需安装阀门最好选闸阀且在运行中全开；调节阀则应在下游5DN之后的管路中。</div>
<div><img decoding="async" style="width: 600px; height: 378px;" src="/uploads/allimg/210330/1-210330163A3G6.jpg" alt="" /></div>
<div>孔板流量计精准安装图</div>
<div></div>
<div>引压管路的内径与管路长度和介质脏污程度有关，通常在45米以内用内径为8-12mm的管子。测量液体流量时引压管水平段应在同一水平面内。若是在垂直管道上安装节流件，引压短管之间相距一定的距离（垂线方向），这对差压变送器的零点有影响，应通过“零点迁移”来校</div>
<div><img decoding="async" style="width: 600px; height: 378px;" src="/uploads/allimg/210330/1-210330163G0V8.jpg" alt="" /></div>
<div>孔板流量计对照图</div>
<div></div>
<div>引压管路应有牢固的支架托承，两根取压管路应尽可能互相靠近并远离热源或震动源，测量水蒸汽流量时，应用保温材料一同包扎，必须时（如气温0℃以下）加伴热管防止结冰。在测量脏污流量时，应附设隔离器或沉降器。引压管路内必须始终保持单相流体状态。被测流体是气体时，引压管路（包括差压计的压力腔）内全部是气相；被测流体是液体时，引压管路内全部是液相，绝对不能有气泡。为此应在引压管路的最低点装排水阀或在最高点装排气阀，</div>
<div><img decoding="async" style="width: 600px; height: 378px;" src="/uploads/allimg/210330/1-210330163H3960.jpg" alt="" /></div>
<div>通过以上图文分析孔板流量计安装图应该对你有所帮助，千万要按照流程找正规的施工单位安装，告诫各位小主不按正规的操作流程走因各种原因会造成孔板流量计计量不准或孔板流量计安装不到位造成的损失应由厂家自行承担</div>
<p><a href="https://www.zhanfengdesign.com/1432/">蒸汽孔板流量计安装图</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>一体化孔板流量计工作原理</title>
		<link>https://www.zhanfengdesign.com/1467/</link>
		
		<dc:creator><![CDATA[jingangxiaohulu3wa]]></dc:creator>
		<pubDate>Tue, 07 Sep 2021 09:23:07 +0000</pubDate>
				<category><![CDATA[孔板流量计技术文章]]></category>
		<category><![CDATA[技术文章]]></category>
		<category><![CDATA[孔板流量计]]></category>
		<category><![CDATA[流量仪表]]></category>
		<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>一体化孔板流量计应用范围特别广泛,在关闭 [&#8230;]</p>
<p><a href="https://www.zhanfengdesign.com/1467/">一体化孔板流量计工作原理</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></description>
										<content:encoded><![CDATA[<div>一体化孔板流量计应用范围特别广泛,在关闭管道的流量测量中各种工具都有应用,如流体方面:单相、混相、洁净、脏污、粘性流等;工作状况方面:常压、高压、真空、常温、高温、低温等;管径方面:从几mm到几m;流动条件方面:亚音速、音速、脉动流等。它在各工业部门的用量约占流量计全部用量的1/4~1/3。</div>
<div><img decoding="async" style="width: 600px; height: 400px;" src="/uploads/allimg/210510/1-210510123J1b7.jpg" alt="" /></div>
<div></div>
<div>在气体的流动管道上装有一个节流装置，其内装有一个孔板，中心开有一个圆孔，其孔径比管道内径小，在孔板前燃气稳定的向前流动，气体流过孔板时由于孔径变小，截面积收缩，使稳定流动状况被打乱，因而流速将发生变化，速度加快，气体的静压随之降低，于是在孔板前后产生压力下降，即差压（孔板前截面大的地方压力大，通过孔板截面小的地方压力小）。</div>
<div></div>
<div>差压的大小和善体流量有确定的数值关系，即流量大时，差压就大，流量小时，差压就小。流量与差压的平方根成正比。</div>
<div></div>
<div><a href="https://www.zhanfengdesign.com/kbllj/">一体化孔板流量计</a>是根据安装于管道中流量检验件产生的差压,已知的流体条件和检验件与管道的几何尺寸来计较流量的仪表。</div>
<div><img decoding="async" style="width: 600px; height: 400px;" src="/uploads/allimg/210510/1-210510123KL12.jpg" alt="" /></div>
<div></div>
<div>一体化孔板流量计由一次装置（检验件）和二次装置（差压转换和流量显示仪表）组成。通常以检验件形式对一体化孔板流量计分类,如孔板流量计、文丘里流量计、均速管流量计等。</div>
<div></div>
<div>二次装置为各种机械、电子、机电一体式差压计,差压变送器及流量显示仪表。它已发展为三化（系列化、通用化及标准化）程度很高的、种类规格庞杂的一大类仪表,它既可测量流量参数,也可测量其它参数（如压力、物位、密度等）。</div>
<div></div>
<div>一体化孔板流量计的检验件按其作用原理可分为:节流装置、水力阻力式、离心式、动压头式、动压头增益式及射流式几大类。</div>
<div>检验件又可按其标准化程度分为二大类:标准的和非标准的。</div>
<div>所谓标准检验件是只要按照标准文件设计、制造、安装和应用,无须经实流标定即可确定其流量值和估算测量误差。</div>
<div>非标准检验件是成熟程度较差的,尚未列入国际标准中的检验件。</div>
<div>一体化孔板流量计是一类应用非常广泛的流量计,在各类流量仪表中其应用量占居首位。近年来,由于各种新型流量计的问世,它的应用量百分数逐渐下降,但目前仍是非常重要的一类流量计。</div>
<div><img decoding="async" style="width: 466px; height: 400px;" src="/uploads/allimg/210510/1-210510123Q2324.jpg" alt="" /></div>
<div></div>
<div>优点:</div>
<div>（1）应用非常多的孔板式流量计结构牢固,性能稳定可靠,应用寿命长;</div>
<div>（2）应用范围广泛,至今尚无任何一类流量计可与之相比拟;</div>
<div>（3）检验件与变送器、显示仪表分别由不同厂家生产,便于规模经济生产。</div>
<div></div>
<div>缺点:</div>
<div>（1）测量精度普遍偏低;</div>
<div>（2）范围度窄,一般仅3:1~4:1;</div>
<div>（3）现场安装条件要求高;</div>
<div>（4）压损大（指孔板、喷嘴等）。</div>
<p><a href="https://www.zhanfengdesign.com/1467/">一体化孔板流量计工作原理</a>最先出现在<a href="https://www.zhanfengdesign.com">金湖凯铭仪表</a>。</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
